Air Intake Kit (P/ 95000085)
otice
• The maximum length of the air duct must not exceed
96”(244cm).
• The Air Intake Filter should be in visible view, easily
accessible, and labeled. Operators have to inspect
and clean the air filter(s) regularly. A blocked filter can
cause electronic damage to the induction unit.
• Ensure to meet all ventilation requirements in
“Ventilation Requirements” on page 16
NOTE: PACTAN silicone adhesive and caulking gun are
included in the air intake kit for glass installation.
NOTE: One air intake kit is provided for each generator.
COMPOETS
(per Air Intake Kit)
A. Air Duct Flange
B. Flex Aluminum Air Duct
C. Air Filter Holder
D. Air Intake Filter
E. Hose Clamps (x2)
A
A
C
D
B
E
+
ISTALLIG THE AIR ITAKE KIT
1. Use the air duct flange as a template to mark on
the cabinet the location of screw holes and air duct
opening.
2. Cut out an opening with diameter of 90mm (3.5inches)
for the air duct.
3. Fasten each of the air duct flanges with three (3) screws.
Use M4 screws with either countersunk or flat heads.
4. Use rivets (diameter 3.3mm or 1/8-inch) to fasten the
air filter holder “
C
” to the cabinet.
5. Attach the air duct to the air duct flanges with the hose
clamps.
6. Insert the air intake filters and label the location of the
filters for the kitchen staff. Frequent inspection and