8

Electrical Schematic

Models 25, 35, 50, 75 - 115V/60 Hz

Model 50 - 208-230V/60Hz

Model 75 - 208-230V/60 Hz; 220-240V/50 Hz

Models 100 - All Voltages

Legend

SW - On/Off Switch

OL - Overload

TB - Terminal Block

CAP - Start Capacitor

SR - Start Relay

DRN1 - Drain Solenoid (STD IC2)

MTR - Compressor

DRN2 - Drain Solenoid (IC2, Oil Coalescing Option)

FM - Fan Motor

TC1 - Temperature Sensor

Optional Notes:

1. IC1-Includes IC1 Instrument Panel and

Pneumatic Pilot operated Drains.

2. IC2-Includes IC2 Instrument Panel

and Timed Solenoid Drains.

3. DRN2-Optional Cold Coalescing Drain.

Summary of Contents for RNC25

Page 1: ...DELS RNC25 RNC35 RNC50 RNC75 RNC100 CONTENTS GENERAL SAFETY INFORMATION 2 RECEIVING MOVING UNPACKING 2 1 0 INSTALLATION 3 2 0 OPERATION 4 3 0 MAINTENANCE 6 SIZING 6 ENGINEERING DATA 7 ELECTRICAL SCHEM...

Page 2: ...evidence of loss or damage at time of delivery to you insist that a notation of this loss or damage be made on the delivery receipt by the carrier s agent B UNPACKING Check for Concealed Loss or Dama...

Page 3: ...r installation Standard units are designed for indoor installation Contact manufacturer if installing outdoors 1 2 Mounting Mount the dryer on a level solid surface Holes are provided in the dryer bas...

Page 4: ...ranty 1 5 Moisture separator A Separator and Oil Removal Filter where applicable has an internal drain which automatically discharges collected condensate It may be desirable to pipe the condensate fr...

Page 5: ...2 Where the dryer is consistently operating at less than maximum capacity it may be possible to increase the LED set point to minimize air loss Discretionary adjustments to the dryer should only be m...

Page 6: ...d drain mechanism annually To facilitate service maintenance kits are available Please refer to page 11 3 0 Maintenance Sizing Determining dryer capacity at actual operating conditions To determine th...

Page 7: ...29 220 183 350 292 Electrical Nominal Voltages 115 1 60 Max Min Voltage 127 104 127 104 127 104 127 104 127 104 Rated Load Amps 3 4 3 9 5 9 7 4 10 3 Locked Rotor Amps 18 0 22 0 28 0 35 0 48 0 Minimum...

Page 8: ...load TB Terminal Block CAP Start Capacitor SR Start Relay DRN1 Drain Solenoid STD IC2 MTR Compressor DRN2 Drain Solenoid IC2 Oil Coalescing Option FM Fan Motor TC1 Temperature Sensor Optional Notes 1...

Page 9: ...G 18 3 16 18 3 16 18 3 16 20 11 16 20 11 16 H 21 3 16 21 3 16 21 3 16 24 3 16 24 3 16 I 18 1 2 18 1 2 18 1 2 24 24 J 16 1 2 16 1 2 16 1 2 21 13 16 21 13 16 Inlet Outlet Connections 1 2 MPT 1 2 MPT 1 2...

Page 10: ...gh air outlet temperature 2 Refrigeration system not func tioning properly resulting in high air outlet temperature 3 Dryer is running with no load a Power failure b Line disconnect switch open c Blow...

Page 11: ...0 120 5 G4130 120 8 G4130 120 9 G4130 121 11 G4130 121 9 G4130 121 9 G4130 122 10 G4130 122 11 G4130 122 15 Compressor Only G4130 108 34 G4130 108 61 G4130 108 35 G4130 108 38 G4130 108 39 G4130 108 4...

Page 12: ...T OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUDING DESIGN MANUFACTURE OR INSPECTION OF THE EQUIPMENT OR ITS FAILURE TO DISCOVER REPORT REPAIR OR MODIFY LATENT DEFECTS INHERENT THEREIN THE MANUFACTURER H...

Reviews: