background image

3-1-618    Page 1 

SECTION 1 
DANGER NOTICES 

 

 

DANGER 

 

Read 

and 

understand 

the 

following 

DANGER  NOTICES  before  moving  or 
operating  the  pump  or  any  pump  package 
unit equipment. 
 
Reciprocating pumps are machines capable 
of  producing  high  fluid  pressures  and  flow 
rates  and  are  designed  to  be  used  with 
proper  care  and  caution  by  trained, 
experienced 

operators. 

TO 

AVOID 

PERSONAL  INJURY,  DEATH  AND/OR 
EQUIPMENT 

DAMAGE, 

READ 

AND 

THOROUGHLY 

UNDERSTAND 

THE 

FOLLOWING  DANGER  NOTICES  PLUS 
THE  ENTIRE  OPERATING AND SERVICE 
MANUAL  BEFORE  ATTEMPTING  TO 
MOVE OR OPERATE THE PUMP.
  Contact 
a  Gardner  Denver  service  representative  if 
you  are  unable  to  comply  with  any  of  the 
danger  notices  or  procedures  described  in 
these documents. 
 
Closely  examine  the  pump  performance 
data  upon  pump  delivery  to  become 
thoroughly  familiar  with  the  operating  limits 
for  this  pump  model.    The  pump  must 
never  be  operated  at  speeds,  pressures 
or  horsepower  exceeding  the  maximum 
values or at speeds below the minimum.  
Failure  to  observe  the  operating  limits 
could  result  in  personal  injury,  death, 
and/or  equipment  damage  and  will  void 
the  warranty.
    Alterations  to  the  pump,  or 
application  of  the  pump  outside  the  limits, 
must  not  be  made  without  Gardner  Denver 
written  approval,  together  with  a  new  set  of 
performance  data,  as  dangerous  operating 
conditions could result. 
 
Keep in mind that full operator attention and 
alertness  are  required  when  operating  high 
pressure  pumping  equipment.    Operators 
should  not  begin  or  continue  operations 
when tired, distracted or under the influence 
of  alcohol  or  any  type  of  prescription  or 
nonprescription drugs. 
 
The timely replacement of expendable parts 
and any other worn or damaged parts can 

 prevent  equipment  damage  and  possible 
injury.    The  original  parts  used  in  Gardner 
Denver  pumps  are  designed  and  tested  to 
exacting  standards  to  provide  high  quality 
performance  and  durability.    Your  best 
insurance 

in 

maintaining 

these 

characteristics  is  to  use  genuine  Gardner 
Denver replacement parts. 
 
A  broad  range  of  danger  notices  are 
covered  on  these  pages,  however,  they 
cannot  substitute  for  training,  experience 
and common sense in the safe operation of 
high pressure pumping equipment. 

 

 
HAMMER LUG FASTENERS 
 

 

DANGER 

 
On  pumps  equipped  with  hammer  lug 
unions and/or hammer lug valve covers the 
following  precautions  must  be  observed  to 
avoid 

personal 

injury, 

death 

and/or 

equipment  damage  due  to  contact  with  the 
hammer,  broken  parts  from  the  hammer,  
lugs  or  other  objects  propelled  by  hammer 
blows.    When  tightening  or  loosening 
hammer  lug  unions  and  valve  covers, 
operators or maintenance personnel should: 
 

 

Inspect  the  hammer  and  hammer  lugs  
to  insure  they  are  all  in  good  condition.  
Replace  any  of  these  parts  which  are 
cracked, damaged or badly worn. 

 

 

Wear safety shoes and safety glasses. 

 

 

Alert  other  personnel  to  move  away 
from the area. 

 

 

Check to insure they have safe footing. 

 

 

Fully  engage  the  hammer  bar,  if  one  is 
used,  to  prevent  it  from  disengaging 
violently  from  the  cover  as  a  blow  is 
struck. 

 

 

Wipe  their  hands  and  the  hammer 
handle and maintain a firm grip on the 
handle  to  avoid  losing  control  of  the 
hammer  while  swinging  and  striking.

Summary of Contents for GD-3000

Page 1: ...ECN 1058968 GARDNER DENVER 3 1 618 Revision D April 2011 WELL SERVICING PUMP MODEL GD 3000 OPERATING AND SERVICE MANUAL...

Page 2: ...in pump maintenance and repair They are ready to respond and assist you by providing fast expert maintenance and repair services For the location of your local authorized Gardner Denver distributor r...

Page 3: ...peration and minimal downtime DANGER Danger is used to indicate the presence of a hazard which will cause severe personal injury death or substantial property damage if the warning is ignored WARNING...

Page 4: ...Ordering Repair Parts i Foreword ii Index iv List of Illustrations v Section 1 Danger Notices 1 Section 2 Design Description and Specifications 9 Section 3 Preparation Operation and Maintenance 15 Se...

Page 5: ...ly Routine Maintenance Schedule 19 Oil Stop Head Seal Retainer and Crosshead Guide End Plate 24 Ordering Instructions Repair Parts i Performance Rating 14 Periodic Routine Maintenance Schedule 18 Plun...

Page 6: ...2 GD 3000 Power End 10 Figure 2 3 GD 3000 Power End Top View 11 Figure 2 4 GD 3000 Gear Reduction Unit 12 Figure 2 5 GD 3000 Fluid End 13 Figure 3 1 Lubricant Recommendations 17 Figure 4 1 Tightening...

Page 7: ...begin or continue operations when tired distracted or under the influence of alcohol or any type of prescription or nonprescription drugs The timely replacement of expendable parts and any other worn...

Page 8: ...e they have safe footing Fully engage the wedge to prevent it from disengaging violently from the cover as a blow is struck Wipe their hands and the hammer handle and maintain a firm grip on the handl...

Page 9: ...nnected to the lifting attachments normally built into the package unit support skid Packages too large to lift as fully assembled should be separated into smaller loads For these smaller loads the li...

Page 10: ...f pressure Any pipe line used to direct pressurized relief flow to another location such as a collecting tank is not blocked The discharge system is not blocked and all the discharge line valves are o...

Page 11: ...trols are clearly tagged with warnings not to start the pump while repair work is in process Whenever the pump is operating continually monitor the entire suction discharge and pump lubricating system...

Page 12: ...eration and stop ongoing operation if flammable or explosive vapors are detected Hot surfaces sparks electric current or engine exhaust could ignite flammable or explosive vapors Each engine used as a...

Page 13: ...damage The operators should take frequent rest breaks and cease operations when they become tired or distracted Before the equipment is started the work area must be inspected and properly prepared t...

Page 14: ...quality of design construction and safety since these components are among the most critical to the safe operation of high pressure liquid jetting blasting and cleaning equipment After you have selec...

Page 15: ...r software developed by American Gear Manufacturers Association The issue of personnel safety is the most important topic covered in this manual Therefore in the beginning of this manual the user is i...

Page 16: ...ques presents information useful for pump rebuilding and assembly including dimensional and tolerance data running clearances for all bearings and recommended fastener torques PUMP DESIGN The GD 3000...

Page 17: ...kle joint design is essentially standard but utilizes a large knuckle 7 and crosshead 13 5 thus allowing extremely high rod load 350 000 lbf See FIGURE 2 3 Also the pump has a drain pan to collect the...

Page 18: ...n the bottom of the frame in the center cylinder Oil passages at the forward part of the frame members allow the end cylinders to drain to the center Oil is also drained from three 1 crosshead drains...

Page 19: ...olt nuts The conventional valve over valve configuration offers field proven arrange ment in terms of valve and spring performance Improvements in the fluid end life come from increasing fluid cylinde...

Page 20: ...10 49 13 12 22 007 5 11 19 635 0 065 3 62 4 54 5 68 6 72 8 44 10 52 12 96 16 20 17 825 5 5 11 23 758 0 078 4 38 5 49 6 88 8 13 10 21 12 73 15 68 19 60 15 000 5 75 11 25 967 0 086 4 79 6 00 7 52 8 89 1...

Page 21: ...ges 5 Remove the breather and either plug or tape the opening 6 Coat the gear reducer input shaft and all extension rods with a heavy rust preventive 7 Plug drain holes at the bottom of the pump frame...

Page 22: ...nts In the past failure to meet these requirements has lead to pump damage because of restricted oil flow in the lube pump inlet Therefore the following guidelines developed as a result of long experi...

Page 23: ...o the volume to be pumped by the triplex pump so that there is no less than 40 psi charge when the triplex pump operates at its maximum flow The first startup and several hours of the pump run in are...

Page 24: ...pressure rating for 30 minutes 11 During this time observe the suction vacuum gage reading oil pressure and temperature and check for leaks 12 Run the pump at 80 90 strokes per min at the following l...

Page 25: ...perform these tasks 4 Listen for any abnormal noise or rough operation which may indicate the need for fluid end maintenance such as changing valves or valve seats Due to very high pressures in the t...

Page 26: ...ps Petroleum EP 500 Summer or EP 300 Winter 10 F Shell Oil Co Torcula Oil 32 50 F Torcula Oil 100 20 F Torcula Oil 150 15 F Torcula Oil 320 10 F Sun Oil Co Rockdrill 500 Light 5 F Rockdrill 1000 Heavy...

Page 27: ...ile working on pump FLUID END SERVICE This discussion starts with the description of steps necessary for removal and installation of the fluid cylinder assembly and proceeds to the removal and replace...

Page 28: ...nger clamps piping connections and auxiliary equipment FIGURE 4 1 Tightening Sequence for Fluid End Nuts Plunger and Packing Replacement This service procedure can be performed with the fluid cylinder...

Page 29: ...nt twisting while loosening the stuffing box 4 Loosen the stuffing box using the stuffing box wrench 5 Carefully remove the stuffing box from the cradle area 6 Clean and oil the packing bore in the st...

Page 30: ...ng the engine inadvertently The power end service procedures deal first with major assemblies namely crosshead connecting rod crankshaft and knuckle joints and then describe how to access all individu...

Page 31: ...ice to the thread of the crosshead front half and lift off 14 Remove the thrust bearing 15 Remove the snap rings from the wrist pin 16 Remove the wrist pin while supporting the crosshead back half 17...

Page 32: ...the crankshaft from disengaging with the frame see Special Tools section of Parts Manual 8 Move the gearbox and the splined adapter to the service area Crankshaft Assembly 1 Remove the pump from the...

Page 33: ...he right side of the frame and the left end bearing and center left bearing out the left side of the frame 17 With bearing locks removed bearings may be driven out of bore with a hammer and brass or a...

Page 34: ...3 Clogged suction line 3 Clean out line 4 Suction and or discharge 4 Remove the obstruction valves propped open Low Discharge Pressure 1 Worn or fluid cut valve 1 Replace valve assembly 2 Valve proppe...

Page 35: ...settling time in supply tank Reduce pump speed 10 Air entering suction line 10 Repair suction line 11 Air entering charging pump 11 Tighten or replace shaft packing or seal 12 Air entering or charge...

Page 36: ...ise transmitted to 11 See Excessive Valve power end Noise problem 12 Cavitation noise transmitted 12 See Cavitation Fluid to or causing shock loading in Knock or Hammer problem power end Excessive Val...

Page 37: ...and sealing surface 4 Corrosion due to wrong 4 Determine and install correct stuffing box material stuffing box for pumped fluid 5 Stuffing box bore worn 5 Replace stuffing box Pumped Fluid In 1 Worn...

Page 38: ...ons Customer Service 5 Wrong size packing 5 Install correct size packing 6 Improper packing installation 6 Check installation procedure and install correctly 7 Excessive crosshead wear 7 Replace cross...

Page 39: ...r Hammer problem Stud Failures 1 Catastrophic failures 1 See Catastrophic Failures problem 2 Improper nut torquing 2 Check torque specifications and torque to correct values 3 Stud bending due to unev...

Page 40: ...Assembled in Journal Bearing Housing 7 755 7 759 Crosshead Guide Bore 302TLS100 13 500 13 502 Babbitt Crosshead Guide Bore 303TLS100 13 557 13 562 Crosshead without Babbitt 302TLS005M 13 487 13 489 C...

Page 41: ...sshead Guide to Pump Frame 3 4 10 200 Crankshaft Bearing to Pump Frame 3 4 10 290 Suction Manifold to Fluid End 7 8 9 320 Discharge Flange to Fluid Cylinder Nuts 1 1 8 12 1080 Gear Reducer to Pump Fra...

Page 42: ...to Purchaser whichever occurs first The exceptions are as follows 1 Power end is warranted for twelve 12 months from date of start up or eighteen 18 months from date of delivery to the Purchaser whic...

Page 43: ...o title the foregoing warranty is the sole and exclusive warranty of the Company The Company hereby extends other manufactures warranty or guaranties if any given to Company by such manufacturer but o...

Page 44: ...breach of this warranty must be commenced within one year after the date upon which the cause of action occurred Any adjustment made pursuant to this warranty shall not be construed as an admission b...

Reviews: