Page 15
4990140010 Date:03/15
XK12 Installation, Operating & Maintenance Manual
Page 15
XK12 Installation, Operating & Maintenance Manual
Installation
Figure 10b Reactive, separate ancillaries.
3.10
Package 2 - Separate ancillaries with reactive
discharge silencer
Compressors should never
be started against pressurised
discharge lines or tanks.
CAUTION
Ref. No.
Description
1 XK-12 Basic M/C - (or high speed unit)
2 10” Cyclonic Inlet Filter
3 3.75” Hose Clip
4 Hose
Adaptor (Cuff ) - Nitrile
5 Ducting -2m x 89mm Bore
6 Inlet Flange - XK-12
7 Inlet gasket
8 Commissioning Filter XK-12 / XK-18
9 Gasket - Outlet Port
10 Outlet Blanking Flange
Ref.No. Description
11 Outlet Flange (S0W) - 70mm Bore
12 Relief valve - 1.25”, 2.5barg
13 Flange TW1 (S0W) - 80/90mm Bore
14 Gasket, 90mm NB, TWI
15 Manifold Gasket
16 ‘Drum’ Reactive Silencer Assembly
17 Check
Valve Kit (3” BSP Outlet)
18 Friction Coupling (K1310/DIN100)
19 Shear
Coupling (K1310/DIN100)
20 Storz Coupling - 3” BSP
**
- Indicates locally supplied item.
*
- Indicates customer supplied pipework.