Technical Data

Type

WP 600

WP 900

WP 1200

WP 1800

WP 2500 

Art. No.

7849

7852

7855

7858

7859

Rated power

5 W 

10 W

15 W

25 W

28 W

Flow

10 l / min

15 l / min

20 l / min

30 l / min

37 l / min

Max. delivery head

1.0 m

1.5 m

1.8 m

2.0 m

2.0 m

Max. submersion depth

1.0 m

1.0 m

2.0 m

2.0 m 

2.0 m

Power cable

10 m

10 m

10 m

10 m

10 m

H05 RNF

H05 RNF

H05 RNF

H05 RNF

H05 RNF

Fitting

26.5 mm 

26.5 mm 

26.5 mm 

26.5 mm 

26.5 mm 

(G 3 /4)

-

(G 3 /4)

-

(G 3 /4)

-

(G 3 /4)

-

(G 3 /4)

-

male thread male thread male thread male thread male thread

Max. media temperature

35 °C

35 °C

35 °C

35 °C

35 °C

Mains voltage 

230 V

230 V

230 V

230 V

230 V

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

Noise level  L

WA

1)

48 dB (A)

48 dB (A)

48 dB (A)

49 dB (A)

49 dB (A)

1) Measuring method according to EN 60335 -1

Service 

GARDENA guarantees this product for 3 years (from date of 
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge 
if the following conditions apply:

The unit must have been handled properly and in keeping with
the requirements of the operating instructions.

Neither the purchaser or a non-authorised third party have
attempted to repair the unit.

The feed impeller is a wearing part and is not covered by the 
guarantee.

This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.

If a fault occurs with your Fountain Pump, please return the
faulty unit together with a copy of the receipt and a description
of the fault, with postage paid to one of the GARDENA Service
Centres listed on the back of these operating instructions.

Where to store

Dismantling

1. Disconnect the plug!
2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically

upwards out of the filter tank.

5. Pull the suction filter casing 

1

for-

wards and remove it.

6. Remove the foam filter 

2

from the 

suction piece of the pump.

7. Turn the pump casing 

3

to the left to

the limit stop and then 
pull it straight towards the front and
remove it! Do not tilt! 

8. Pull the feed impeller 

4

out of the

motor casing 

6

.

.

Then assemble all the fittings reversing the order and direction 

in which they were dismantled. Please take care that the seal
ring 

5

is properly re-fitted.

Make sure while assembling that you attach the pump casing 
with the pressure joint being cated, press it firmly and then 
turn it straight to the right.

Observe the markings.

Storage

A

The pump should be stored out of the reach of children.

1. Remove the pump from the pond and store away from frost

before the first frost sets in.

2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.

The mains plug must not be submerged.

Complaints / Repairs 

A decrease in the performance of the pump (height of fountain 
de-creases) may be caused by a dirty filter.

Clean the filter if necessary.

If you have any problems with your Fountain Pump, please 
contact our Service or return the defective unit together with 
a short description of the problem – in case of guarantee, with 
the warranty card duly completed and signed – postage paid 
to one of the GARDENA Service Centres listed on the back of 
this leaflet.

1

2

3

4

5

6

Summary of Contents for WP 600

Page 1: ...loi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp S Bruksanvisning Font n Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua DK Br...

Page 2: ...kname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 22 27 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 28 33 I Prima di mettere in uso...

Page 3: ...rating of 30 mA DIN VDE 0100 702 and 0100 738 The pump must be placed on solid even ground Please ask your electrician for his advice Mains power cables Mains power cables should not have a smaller c...

Page 4: ...s If the feed impeller becomes blocked the pump and the filter should be cleaned see above Starting the pump Avoid dry operation Horizontal or second outlet Remote control Pond aeration Filling the fi...

Page 5: ...the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions Where to store Dismantling 1 Disconnect the plug 2...

Page 6: ...ne Springvandspumper Typ WP 600 Art Nr 7849 Type Art No Type WP 900 R f rence 7852 Typ Art nr Typ WP 1200 Art nr 7855 Modello Art Tipo WP 1800 Art N 7858 Type Varenr WP 2500 7859 EU Richtlinien 98 37...

Page 7: ...ENA Magyarorsz g Kft K sm rk utca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 It...

Reviews: