Warranty
15
GB
14
GB
Technical Data
Type
WP 600
WP 900
WP 1200
WP 1800
WP 2500
Art. No.
7849
7852
7855
7858
7859
Rated power
5 W
10 W
15 W
25 W
28 W
Flow
10 l / min
15 l / min
20 l / min
30 l / min
37 l / min
Max. delivery head
1.0 m
1.5 m
1.8 m
2.0 m
2.0 m
Max. submersion depth
1.0 m
1.0 m
2.0 m
2.0 m
2.0 m
Power cable
10 m
10 m
10 m
10 m
10 m
H05 RNF
H05 RNF
H05 RNF
H05 RNF
H05 RNF
Fitting
26.5 mm
26.5 mm
26.5 mm
26.5 mm
26.5 mm
(G 3 /4)
-
(G 3 /4)
-
(G 3 /4)
-
(G 3 /4)
-
(G 3 /4)
-
male thread male thread male thread male thread male thread
Max. media temperature
35 °C
35 °C
35 °C
35 °C
35 °C
Mains voltage
230 V
230 V
230 V
230 V
230 V
Frequency
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
Noise level L
WA
1)
48 dB (A)
48 dB (A)
48 dB (A)
49 dB (A)
49 dB (A)
1) Measuring method according to EN 60335 -1
Service
GARDENA guarantees this product for 3 years (from date of
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge
if the following conditions apply:
•
The unit must have been handled properly and in keeping with
the requirements of the operating instructions.
•
Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The feed impeller is a wearing part and is not covered by the
guarantee.
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.
If a fault occurs with your Fountain Pump, please return the
faulty unit together with a copy of the receipt and a description
of the fault, with postage paid to one of the GARDENA Service
Centres listed on the back of these operating instructions.
Where to store
Dismantling
1. Disconnect the plug!
2. Remove the pump from the water.
3. If necessary remove the gravel.
4. Pull the pump pointing vertically
upwards out of the filter tank.
5. Pull the suction filter casing
1
for-
wards and remove it.
6. Remove the foam filter
2
from the
suction piece of the pump.
7. Turn the pump casing
3
to the left to
the limit stop and then
pull it straight towards the front and
remove it! Do not tilt!
8. Pull the feed impeller
4
out of the
motor casing
6
.
.
Then assemble all the fittings reversing the order and direction
in which they were dismantled. Please take care that the seal
ring
5
is properly re-fitted.
➔
Make sure while assembling that you attach the pump casing
with the pressure joint being cated, press it firmly and then
turn it straight to the right.
➔
Observe the markings.
Storage
A
The pump should be stored out of the reach of children.
1. Remove the pump from the pond and store away from frost
before the first frost sets in.
2. Clean and check the pump carefully.
3. Store the pump in a container filled with water.
The mains plug must not be submerged.
Complaints / Repairs
A decrease in the performance of the pump (height of fountain
de-creases) may be caused by a dirty filter.
➔
Clean the filter if necessary.
If you have any problems with your Fountain Pump, please
contact our Service or return the defective unit together with
a short description of the problem – in case of guarantee, with
the warranty card duly completed and signed – postage paid
to one of the GARDENA Service Centres listed on the back of
this leaflet.
1
2
3
4
5
6