background image

11

10

GB

Applications:
Examples – System extensions – Product Recommendations

Example for application:

Water jets may be integrated into water features.

Model

Cascade

Water

Foaming

Water

Water-

Cascade

Bell

Jet Spray Fleur-de-Lis

fall

Rotating

Art.

7814 *

7816

7818

7820

7822

7823

No.

WP 600

7849

××

××

××

WP 900

7852

××

××

××

××

××

WP 1200

7855

××

××

××

××

××

××

WP 1800

7858

××

××

××

××

××

××

WP 2500

7859

××

××

××

××

××

××

* contained in delivery volume

Example for application:

Underwater lighting of water jets and pond edges.

Products:

GARDENA Underwater Light

Art. No. 7951 

GARDENA 

lightline Transformers 

Example for application:

For installation in ponds and fountains.

Product:

GARDENA Light / Fountain Nozzle

Art. No. 7953 

Water jets for 
26.5 mm (G 3 /4) thread 
connections

Adaptable lamps 

Light / Fountain Nozzle 

GARDENA Fountain Pump 
WP 600 / WP 900 / WP 1200 / WP 1800 / WP 2500

Welcome to GARDENA aquamotion ...

Please read these operating instructions carefully and observe 
the notes given.
Use the instructions to familiarise yourself with the equipment, 
the operating controls, their correct use, and the notes on safety.

A

For safety reasons, children under 16 as well as persons 

not familiar with these operating instructions should not use this
pump.

Keep these operating instructions in a safe place.

The Applications Range of Your Pump

GARDENA Fountain Pumps have been designed for private use.
They are not designed for operating watering tools and systems.
The pumps may be used indoors as well as outdoors.

A

GARDENA Fountain Pumps have not been designed for con-

stant use in the industrial sector. Corrosive, easily combustible,
aggressive or explosive substances (e.g. petrol, petroleum, nitro
thinner) as well as salt-water or food / drinking water must not
be pumped.

Intended purpose 

Attention 

For Your  Safety

Operating the Pump  

The pump should be operated via a residual
current device with a residual current rating of

30 mA (DIN VDE 0100 -702 and 0100 -738).

The pump must be placed on solid, even
ground. Please ask your electrician for his
advice.

Mains power cables 

Mains power cables should not have a smaller
cross-section than a rubber sheathed cable 
of the designation H05 RNF. Extension cables
must meet the requirements of DIN VDE 0620.

For Austria 

In Austria power cables should correspond to
ÖVE-EM 42, T 2 (2000) /1979 § 22 according
to § 2022.1. According to this standard pumps
used in swimming pools and ponds should 
only be operated via an isolating transformer.
Please contact your electrician.

For Switzerland 

In Switzerland mobile appliances which are
used outdoors, must be connected via a 
residual-current device.

Visual check 

Before operating the pump, look to see if there
is any damage of the pump (esp. regarding
power cable and plug). A damaged pump
must not be used. In case of damage, please
have the pump checked by our GARDENA
Service Centre or by an authorised electrician.

Check line voltage 

Check line voltage. Data indicated on the type
plate must match technical data of the mains
supply.

Do not operate pump when there are 
people in the water 

The pump must not be operated when there
are people in the water.

Swimming pools and garden ponds 

Swimming pools and garden ponds should 
be designed according to international and
national design regulations. Please consult 
a professional electrician.

Do not use power cable to carry the pump 

Do not use the power cable to carry the 
pump or to pull the plug out of the socket.
Protect the power cable from heat, oil and
sharp edges.

Disconnect plug 

Please unplug the pump after operation and
before carrying out any maintenance works.

Temperature of the liquid used 

The temperature of the liquid used must not
be below 4 °C or above 35 °C.

Wear and reduced output 

Sand and other abrasive substances in the 
liquid cause in-
creased wear and reduce the output of the
pump.

Observe local noise prevention 
regulations 

Please observe the local noise prevention 
regulations.

GB

Summary of Contents for WP 600

Page 1: ...loi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp S Bruksanvisning Font n Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua DK Br...

Page 2: ...kname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 22 27 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 28 33 I Prima di mettere in uso...

Page 3: ...rating of 30 mA DIN VDE 0100 702 and 0100 738 The pump must be placed on solid even ground Please ask your electrician for his advice Mains power cables Mains power cables should not have a smaller c...

Page 4: ...s If the feed impeller becomes blocked the pump and the filter should be cleaned see above Starting the pump Avoid dry operation Horizontal or second outlet Remote control Pond aeration Filling the fi...

Page 5: ...the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions Where to store Dismantling 1 Disconnect the plug 2...

Page 6: ...ne Springvandspumper Typ WP 600 Art Nr 7849 Type Art No Type WP 900 R f rence 7852 Typ Art nr Typ WP 1200 Art nr 7855 Modello Art Tipo WP 1800 Art N 7858 Type Varenr WP 2500 7859 EU Richtlinien 98 37...

Page 7: ...ENA Magyarorsz g Kft K sm rk utca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 It...

Reviews: