NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers
approved by GARDENA.
7. TECHNICAL DATA
Battery Blower / Vacuum
Unit
Value (Art. 9338)
Max. Vacuum flow
l/s
160
Mulch ratio
8 : 1
Max. Blow speed
km/h
320
Weight (without Battery)
Blower mode / Vacuum mode
kg
3.0 / 3.9
Sound pressure level L
pA
1)
Uncertainty k
pA
dB (A)
91
2.5
Sound power level L
WA
2)
:
measured/guaranteed
Uncertainty k
WA
dB (A)
98 / 102
4.0
Hand/arm vibration a
vhw
1)
Uncertainty k
a
m/s
2
2.8
1.5
Measuring process complying with:
1)
EN 50636-2-100
2)
RL 2000/14/EC
NOTE: The stated vibration emission value has been measured according to a stand-
ardized test procedure and can be used for comparison of one electric power tool
with another. It can also be used for preliminary evaluation of exposure. The vibra-
tion emission value can vary during actual use of the electric power tool.
System Battery /
smart Battery BLi 40
Unit
Value (Art. 9842/19090)
Value (Art. 9843/19091)
Max. Battery voltage
V (AC)
40
(The max. initial no-load
voltage of the battery
is 40 V, the nominal voltage
is 36 V)
40
(The max. initial no-load
voltage of the battery is
40 V, the nominal voltage
is 36 V)
Battery capacity
Ah
2.6
4.2
Battery charging time
80 % / 100 % (approx.)
min.
65 / 90
105 / 140
Type of Battery
lithium-ion
lithium-ion
Battery Charger QC40
Unit
Value (Art. 9845)
Mains voltage
V (AC)
230
Mains frequency
Hz
50
Rated Power
W
100
Output voltage
V (DC)
42
Max. Output current
A
1.8
24
EN