background image

70

automatically after 30 minutes. The remaining watering time (RUN TIME) 
is shown on the LCD display.

If the valve is opened manually and the manual watering time and a pro-
grammed watering time overlap, the programmed watering is suppressed.

11. Battery

11.1  Status Indicator

If the battery voltage falls below a 

certain level

the 

Batt

. indicator appears

8

. It is possible to initiate watering manually even if the battery capacity is

too low (valve no longer opens), but programmed watering times, however,
are not initiated. Even if the 

battery capacity is too low

to run a program,

if the valve is open it will be closed.

The battery voltage is tested 

during the opening pulse.

In this way you

can 

test the capability of the battery at any time.

To do this, simply

press the 

man On / Off

key 

1

. If the valve opens and the 

Batt

. indicator

does not appear then the battery does not have to be changed.

11.2  Changing the Battery

If you exchange the 

battery within 100 seconds,

the data you have 

entered will be saved 

(program saved).

When the battery is removed the

LCD display extinguishes and programs will not run while the battery is
being changed. When you have inserted a new battery, we recommend 
that you check the data as described under 

“Read / Change Program”.

If you do not insert a new battery within 100 seconds, or if the battery
power was already so low that the valve no longer opened, the water com-
puter is RESET (all program data is deleted). You must re-program your
water computer. The current date / time which was previously displayed
remain unchanged within the given time.

12. Notes on Safety and Operation

A

For safety reasons only a 9 V alkali-manganese battery (alkaline)
type IEC 6LR61 must be used.

.

The minimum water output to ensure that the Water Computer 
functions correctly is 20 - 30 l / h.
For example, at least 10 x 2-litre Drip Heads are required to 
control the Micro-Drip-System.

.

The battery must be exchanged in time to prevent the Water Com-
puter failing due to a low battery when you are away for longer 

Summary of Contents for C 1030 plus

Page 1: ...C 1030 Plus P Instru es de utiliza o Computador de rega C 1030 Plus D Betriebsanleitung Bew sserungscomputer C 1030 plus GB Operating Instructions Water Computer Plus C 1030 PL Instrukcja obs ugi Komp...

Page 2: ...instrucciones 6 22 Garant a 94 P Breves instru es de utiliza o 25 Instru es de utiliza o 23 40 Garantia 94 D Kurz Betriebsanleitung 43 Betriebsanleitung 41 58 Garantie 95 G Summary of Operating Instru...

Page 3: ......

Page 4: ......

Page 5: ...ng instructions may not use the Water Computer Keep these operating instructions in a safe place 2 Proper Use The GARDENA Water Computer Plus C 1030 is suitable and determinated for private use in dom...

Page 6: ...1 year 4 How the Water Computer Works Your GARDENA Water Computer allows you to water your garden com pletely automatically any time you choose up to 3 times a day whether you are using a sprinkler a...

Page 7: ...sing the Menu O K key Entering the Time and Day of the Week a Time hours b Time minutes c Day of the week Entering the Watering Data a Starting time hours b Starting time minutes c Watering time hours...

Page 8: ...s Hours of the current time Minutes Minutes of the current time Seconds Dots between the hours and minutes flash when you have entered or changed the current time hour minute day of the week Day Indic...

Page 9: ...trol unit B Connection socket Socket to connect the control unit C Sleeve nut incl filter To connect the water computer to the tap 6 4 Accompanying Accessories D G Adapter for sleeve nut To connect th...

Page 10: ...o be connected to taps with a G thread 26 5 mm If you are using the adaptor screw the adaptor onto the tap before screwing the Water Computer onto the adaptor Warning Attach and screw on manually Do n...

Page 11: ...Entering the Current Data Time Day 1 Press Menu O K 1 second The hours TIME flash 2 Enter the hours using On Off e g 17 00 3 Press Menu O K to allow you to enter the minutes Range 0 23 4 Enter the min...

Page 12: ...es for the starting time START TIME using Menu O K Range 0 23 2 Enter the minutes for the starting time using On Off e g 30 Confirm the data you have entered and move to the watering time hour using M...

Page 13: ...K Range 00 59 The maximum watering time you can set is 7 hours and 59 minutes 8 3 Setting the Water Cycles 1 Enter the watering cycles using On Off e g watering every 24 hours 24 h 2 Confirm the data...

Page 14: ...en you have finished programming the computer the clock is running Note You can move to the next program level current data watering data On Off Prog normal display at any time during programming by p...

Page 15: ...f key 1 without influencing the program data starting time watering time and watering days 9 Read Change Program You can run through the program levels to check the data you have entered by repeatedly...

Page 16: ...e Battery If you exchange the battery within 100 seconds the data you have entered will be saved program saved When the battery is removed the LCD display extinguishes and programs will not run while...

Page 17: ...to the Water Computer during operation Only use the Water Computer outdoors Warning The Water Computer must not be used indoors The Water Computer must be stored in a dry place away from frost before...

Page 18: ...nual watering man On Off is still possible 13 3 GARDENA Rain Sensor Fig F Together with the GARDENA Rain Sensor Art No 1189 watering is controlled considering natural precipitation Assembly The Rain S...

Page 19: ...e time days Not able to open Weak battery Insert a new alkaline manually using Batt indicator appears battery man key Tap turned off Turn on tap Watering not Weak battery Insert a new alkaline initiat...

Page 20: ...and O K keys there was no longer Re enter data as an opening pulse described If you have any problems with your Water Computer please contact our Customer Service We expressly point out that in accord...

Page 21: ...ordance with the harmonised EU guidelines EU standards of safety and product specific standards This certificate becomes void if the unit is modified without our approval Description of the unit Water...

Page 22: ...ie auf der R ckseite angegebene Service adresse Unfreie Paketeinsendungen werden im Postverteilzentrum ausgefiltert und erreichen uns nicht Nach erfolgter Reparatur senden wir das Ger t frei an Sie zu...

Page 23: ...mpania Exim Euroiberoamericana S A Los Colegios Moravia 200 metros al Sur del Colegio Saint Francis San Jos Phone 506 297 6883 exim_euro racsa co cr Croatia KLIS d o o Stanciceva 79 10419 Vukovina Pho...

Page 24: ...07 32 7 495 647 25 10 info gardena rus ru Singapore Hy Ray PRIVATE LIMITED 40 Jalan Pemimpin 02 08 Tat Ann Building Singapore 577185 Phone 65 6253 2277 hyray singnet com sg Slovak Republic GARDENA Slo...