69
8.5 Display During Automatic Watering
(Fig. Display
during
Example :
automatic watering)
– It is Friday
(Fr
) 18:45, the water com-
puter is programmed for watering every
2 days
(2nd)
.
–
On / Off-Prog.
is set to
On
(watering
desired).
– The remaining watering time (RUN
TIME) is 50 minutes.
– The dots between the hours and
minutes are flashing.
– The clock is running.
– The RUN TIME is counting down.
After the RUN TIME has finished the display shows normal operation.
If the valve is opened by a program it can be closed prematurely at any
time by pressing the
On / Off
key
1
without influencing the program data
(starting time, watering time and watering days).
9. Read / Change Program
You can run through the program levels to check the data you have entered
by repeatedly pressing the
Menu
key and select and check the program
steps by pressing
O.K.
You can change the watering programs as described under “Programming”.
10. Manual Program-Independent man On / Off
Operation
After you have entered data, you can
operate your water computer manually
at any time, independent of the pro-
grammed watering times, by pressing
the
man On / Off
key
1
.
Press the
man On / Off
key once to open
the water flow. Press the same key again
to close the valve.
If you do not manually close the valve,
for safety reasons, watering is ended