Convertingunitfromvacuum
usetobloweruse:
1. Stop unit and unplug the extension cord.
2. Remove the elbow tube and collection bag.
3. Remove the vacuum tubes by releasing the latch on the vacuum
inlet cover and rotating the cover until the tubes are released
from the latches of the retaining posts.
4. Close the inlet cover and make sure it is latched closed.
5. Re-install the blower tube. Refer to FITTING THE BLOWER
TUBE for instructions on how to attach this item.
NOTE: A safety switch will prevent the unit from starting if the inlet
cover is not latched closed.
4. Operation
WARNING:
Do not use the unit without the tubes or collection bag properly
attached to avoid flying debris and/or impeller contact which can cause serious
injury.
Alwayswearglovesanduseeyeprotectiontopreventrocksordebrisfrom
beingblownorricochetingintotheeyesandfacewhichcanresultinblindnessor
seriousinjury.
Cables:
Use only 1.00mm
2
size cable up to 40 metres length maximum.
Maximum rating:
1.00mm
2
size cable
3000 W
Mains cables and extensions are available from your local
approved service centre. Only use extension cables specifically
designed for outdoor use.
Connectingtheunit–
cablelock/extensioncables:
Loop the extension cable
i
and insert it into the cable lock
o
.
This prevents unintentional separation of the electrical connection.
Then connect it to the mains cable.
i
o
22