background image

DESCRIPTION

Tjernlund's Hot Shot™ Universal Stove Blower Heat Shield allows for the proper installation of the fan on stoves which do
not have an existing heat shield.

INSTALLATION

ATTACHING HEAT SHIELD TO BLOWER HOUSING

1. Unscrew and remove Stove Top Edge Clip from the heat shield bracket, (See Figure A). Save for later use in Step 7.

2. Unscrew the (2) brackets from the inside of the heat shield, (See Figure B).

3. Separate the SB1 main blower housing and the back cover by removing the (6) screws that attach them, (See Figure C).

4. Attach the (2) brackets removed from the heat shield in Step 2 to the outside front of the main blower housing. Insert 

screws through housing from inside the SB1 main blower housing and screw into the (2) feet of each bracket, (See 
Figures D and E).  

5. Reattach the back cover to the SB1 main blower housing with (6) screws removed in Step 3, (See Figures E and F).

Hot Shot

Universal Stove Blower Heat Shield, P/N (950-9200)

©2011 TJERNLUND PRODUCTS, INC.  ALL RIGHTS RESERVED

P/N: 8504184

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

READ OWNERS INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION.

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT. DO NOT DESTROY.

FIGURE A

FIGURE B

FIGURE C

FIGURE D

HEAT 
SHIELD

FIGURE E

FIGURE F

BRACKETS
ATTACHED

Reviews: