background image

2. ASSEMBLY

  

 DANGER! Risk of injury!

 

  Injury when the product starts accidentally.

 

 Disconnect the product from the mains before 

you assemble the product.

Connection possibilities of the connection nipple 

[ Fig.  A1 ]:
The hose can be connected via the connection nipple 

(4)

 

with different hose diameters or the GARDENA Connection 

System.

Large hose diameter

Detach nipple at 

(a)

  

[ Fig. A2 ]

GARDENA Connection System /  

Art. 9046: Medium hose diameter

Detach nipple at 

(b)

  

[ Fig. A3 ]

Small hose diameter

Do not detach nipple  

[ Fig. A4 ]

When using the largest hose diameter, the pump has the 

maximum delivery capacity.

Pump

Art. 9030

Art. 9032

Art. 9040

Art. 9042

Art. 9046

Small hose 

 diameter
Art. GARDENA  

Hose Clamp

25 mm (1")

 

Art. 7193

25 mm (1") 

Art. 7193

32 mm (1 1/4") 

Art. 7194

Medium hose 

diameter 

Art. GARDENA  

Hose Clamp

GARDENA 

 Connection 

 System G 1"

GARDENA 

 Connection 

 System G 1"
32 mm (1 1/4") *  

Art. 7194

38 mm (1 1/2") 

 

 

Art. 7195

Large hose  

diameter
Art. GARDENA  

Hose Clamp

38 mm (1 1/2") 

Art. 7195

38 mm (1 1/2") 

Art. 7195

51 mm (2") 

Art. 7196

When using the 38 mm (1 1/2") hose, we recommend the 

GARDENA Flat Hose Set Art. 5005 with 10 m hose and 

hose clamp.
*  For Art. 9042 an additional connection nipple 

ß

4a

 for 

1 1/4" hoses is supplied.

To connect the hose via the connection nipple:
1. When using the large diameter hose, cut off the 

 connection  nipple 

(4)

 at 

(a)

.

2. Only for Art. 9046: When using the medium hose 

 diameter, cut off the connection nipple 

(4)

 at 

(b)

.

3. Push the hose onto the connection nipple 

(4)

.

4. Fix the hose to the connection nipple 

(4)

 e. g. with 

a GARDENA Hose Clamp.

Connect hose via the GARDENA Connection System:
With 25000DIRT (Art. 9046) the hose cannot be connected 

via the connection nipple 

(4)

 with the GARDENA Connec-

tion System.
19 mm (3/4") / 15 mm (5/8") and 13 mm (1/2") hoses can 

be connected via the GARDENA Connection System.
We do not recommend hose diameters smaller than 

25 mm (1"), otherwise there will be a significant reduction 

in the output of the delivery rate.

Hose diameter

Pump connection

13 mm (1/2")

GARDENA Pump Connection Set Art. 1750

15 mm (5/8")

GARDENA Pump Connection Set Art. 1750

19 mm (3/4")

GARDENA Pump Connection Set Art. 1752

1. Cut off the connection nipple 

(4)

 at 

(b)

.

2. Connect the hose to the connection nipple 

(4)

 via the 

appropriate GARDENA Connection System.

To assemble the pump connection [ Fig. A5 ]:

  

 DANGER! Risk of injury!

 

Cut injury by the impeller.

 

 Operate the pump only with the elbow 

 connector.

The hose can be easily connected and disconnected using 

the locking devices 

(2)

 on the elbow connector 

(1)

.

1. Screw the elbow connector 

(1)

 clockwise into the pump 

until it stops. (If the hose is to be installed horizontally, 

the elbow connector 

(1)

 can be screwed out again up  

to half a turn.)

2. Only for Art. 9042 / 9046: Screw the connection  

piece 

(3)

 into the connection nipple 

(4)

.

3. Push the connection nipple 

(4)

 of the hose into the 

elbow connector 

(1)

 until it stops and it engages audibly 

and visibly.  

The hose is securely connected to the pump.

3. OPERATION

  

 DANGER! Risk of injury!

 

  Injury when the product starts accidentally.

 Disconnect the product from the mains before 

you connect, adjust or transport the product.

To pump water:
If the pump cannot be immersed via the handle, the  

pump must always be immersed via a rope. Attach  

the rope by pulling it through the eyelets provided and  

knotting it.  Minimum immersion depth during initial 

 operation see 7. TECHNICAL DATA. 

EN

13

Summary of Contents for 9000CLEAR

Page 1: ...9000DIRT Art 9040 16000DIRT Art 9042 25000DIRT Art 9046 9000CLEAR Art 9030 11000CLEAR Art 9032 EN Operator s Manual Clear Water Submersible Pump Dirty Water Submersible Pump EN ...

Page 2: ...A1 4 y A2 A3 y A4 A5 Art 9030 Art 9032 Art 9040 Art 9042 Art 9046 1 G1 1 2 1 1 G1 1 G1 1 1 G1 2 3 4 4 4 ß 4a 1 O1 min 10 cm Art 9030 min 3 cm q 5 min 10 cm q 5 O2 5 5 T1 8 7 7 0 6 6 9 3 ...

Page 3: ...must only be used to pump water The pump is fully submersible water tight encapsulation and is submerged in water for max submersion depth see 7 TECHNICAL DATA The product is suitable for pumping the following liquids Clear Water Submersible Pump clean to slightly dirty water with a max particle size of 5 mm Dirty Water Submersible Pump dirty water with a max particle size of Dirty Water Submersib...

Page 4: ...eed through wall v Don t use the power cable for plugging off v If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Mains plug and extension connections must be protected from water splashes Ensure that the electrical connections for plugs and sockets are made in areas safe from flooding Protect the mains...

Page 5: ...em With 25000DIRT Art 9046 the hose cannot be connected via the connection nipple 4 with the GARDENA Connec tion System 19 mm 3 4 15 mm 5 8 and 13 mm 1 2 hoses can be connected via the GARDENA Connection System We do not recommend hose diameters smaller than 25 mm 1 otherwise there will be a significant reduction in the output of the delivery rate Hose diameter Pump connection 13 mm 1 2 GARDENA Pu...

Page 6: ...vel at start up the suction process may take longer 1 Immerse the pump 2 Connect the pump to the mains Attention The pump can start immediately depending on the float switch setting Automatic mode with float switch Fig O1 By adjusting the float switch 5 you have the pos sibility to determine the switching heights For safe operation the float switch must be able to move freely around the pump To ad...

Page 7: ...rom the hose NOTE For any other malfunctions please contact the GARDENA service department Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA 6 TROUBLESHOOTING DANGER Risk of injury Injury when the product starts accidentally v Disconnect the product from the mains before you troubleshoot the product To clean the suction base and the impeller Fig T1 ...

Page 8: ...ade fixing parts turbines light bulbs V belts toothed belts impellers air filters spark plugs visual changes wear parts and consumables are excluded from the warranty This manufacturer s warranty is limited to replacement and repair of products in accordance with the abovemen tioned conditions The manufacturer s warranty does not constitute an entitlement to lodge other claims against us as a manu...

Page 9: ...rpalka Obilježja pumpe Karakteristika pumpe Крива характеристики насоса Caracteristică pompă Pompa karakter eğrisi Помпена характеристика Fuqia e pompës Pumba karakteristik Siurblio charakteristinė kreivė Sūkņa raksturlīkne max 4 940 l h max 3 360 l h max 6 520 l h 4 m max 6 m 3 m 2 m m max 8 110 l h 1 max 5 020 l h max 1 200 l h max 8 500 l h 6 m max 7 m 4 m 2 m m max 9 750 l h 1 max 5 425 l h ma...

Page 10: ...ke påtager os noget ansvar for skader på vores produkter hvis de pågældende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDENA reservedele eller godkendte reservedele fra GARDENA FI Tuotevastuu Saksan tuotevastuulain mukaisesti emme ole vastuussa laitteiden vaurioista jos korjauksia ei ole tehnyt GARDENAn hyväksymä huolto...

Page 11: ...ovime izričito izjavljujemo kako ne prihvaćamo nikakvu odgovornost za oštećenja na našim proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekorištenja originalnih GARDENA dijelova ili dijelova koje odobrava GARDENA RO Răspunderea pentru produs În conformitate cu Legea germană privind răspunderea pentru produs declarăm în mod expres pr...

Page 12: ...one poniżej urządzenie nia w wersji wprowadzonej przez nas do obrotu spełnia niają wymogi zharmonizowanych dyrektyw UE norm bezpieczeństwa UE oraz norm dotyczących konkretnych produktów Niniejsza deklaracja traci ważność w przypadku wprowadzania nieuzgodnionych z nami zmian urządzenia ń HU EU megfelelőségi nyilatkozat Az alulírott a GARDENA Germany AB Pf 7454 S 103 92 Stockholm Svédország megbízot...

Page 13: ...mais notekūdens sūknis Anbringungsjahr der CE Kennzeichnung Year of CE marking Année d apposition du marquage CE Installatiejaar van de CE aanduiding Märkningsår CE Mærkningsår CE merkin kiinnitysvuosi Anno di applicazione della certificazione CE Colocación del distintivo CE Ano de marcação pela CE Rok nadania oznakowania CE CE jelzés elhelyezésének éve Rok umístění značky CE Rok udelenia značky C...

Page 14: ... Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan Husqvarna Zenoah Co Ltd 1 9 Minamidai Kawagoe 350 1165 Saitama gardena jp husqvarnagroup com Kazakhstan LAMED Ltd 155 1 Tazhibayevoi Str 050060 Almaty IP Schmidt Abayavenue 3B 110 005 Kostanay Korea Kyung Jin Trading CO LT...

Reviews: