background image

15

G

Problem

Probable cause

Remedy 

Pump runs, but the suction 

Air cannot escape, since 

v

Open all possible shut-off 

action doesn’t take place.

delivery side is closed 

devices (e.g. spray nozzle)

or remaining water is in the 

in the pressure line, or drain 

pressure hose.

the pressure hose or dis-
connect it during the suction 
action.

Pump runs when out of water 

You didn’t fill the pump with 

v

Fill in liquid (see point 

but does not start pumping 

any liquid before operation.

“3. Initial Operation”).

when in water 

The liquid escapes over 

1. Fill up the pump again (see

the hose which is connected 

point 3. Initial Operation).

to the delivery side during 

2. When starting operation 

the suction action.

hold the pressure hose 
approx. 1 m vertically above 
the pump, until the suction 
action has taken place.

Leaky or damaged suction 

v

Seal the connections or 

hose.

check suction hose for 
damages.

Absolutely vacuum-resistant 
connection is achieved by using 
GARDENA Suction Hoses 
(see point “8. Accessories”).

Leaky screw fitting at the filler 

v

Tighten the screw fitting 

cap 

7

.

(do not use pliers).

Air cannot escape, since 

v

Open all possible shut-off 

delivery side is closed 

devices (e.g. spray nozzle)

or remaining water is in the 

in the pressure line, or drain 

pressure hose.

the pressure hose or dis-
connect it during the suction 
action.

The waiting time wasn’t 

v

Switch on the pump and 

observed.

wait max. 7 min.

Suction filter or backflow 

v

Clean the filter or the back-

preventer in the suction hose 

flow preventer.

clogged.

Too high suction height.

v

Reduce suction height.

In case of any other difficulties concerning the suction action, 
use GARDENA Suction Hoses with Backflow Preventer (see point 
“8. Accessories”) and fill in the liquid to be pumped over the filler 
cap 

7

before operation.

The specified maximum 

Pump is not filled and suction 

1. Fill the pump using the filler 

self-priming height is not 

hose is not held upwards.

neck until it overflows.

2. Hold the suction hose up-

wards during the self-prim
ing phase so that the liquid 
you are going to pump 
cannot flow out of the pump 
via the suction hose.

14

G

Pumping liquid :

Freeing the impeller :

8

9

5

1 m

4. Operation 

When setting up the pump for use in water :

v

Plug the mains plug of the pump into a 230 V / 50 Hz alternat-
ing current socket.

The pump starts.

When setting up the pump for use out of water

1. Fill the pump to overflowing with approx. 2 l of the liquid 

to be pumped (see “3. Initial Operation”, 

“Filling the pump” ).

2. Open all possible shut-off devices in the pressure line 

(watering accessories, Water Stop, etc.).

3. Drain remaining water in pressure hose so that air can escape

during the suction process.

4. Plug the mains plug of the pump into a 230 V / 50 Hz alternat-

ing current socket.

The pump starts.

5. Hold the hose 

5

at the delivery side approx. 1 m vertically

above the pump until the pump begins to pump.

v

If the pump has still not started pumping after 7 minutes, 
unplug the mains plug (see 6. Trouble Shooting).

When using the pump for pressure intensification, the max. per-
missible internal pressure of 6 bar (on the delivery side) must
not be exceeded. The to be increased delivery pressure and the
pump pressure sum up.

Example: pressure at the water tap 1.5 bar, max. pressure of
the GARDENA Dual Pump 5000 / 3 SGP = 3.3 bar,  total pres-
sure = 4.8 bar.

5. Maintenance 

The GARDENA Dual Pump is virtually maintenance-free.

6. Trouble-Shooting 

If the impeller blocks or clogs you can remove the dirt to free 
the impeller.

1. Unscrew the screw plug 

8

using 

a screwdriver.

2. You can now turn the impeller 

shaft 

9

in the casing using a 

screwdriver.
This will free the blocked or clogged 
impeller.

3. Replace the screw plug 

8

using 

a screwdriver.

Starting the pump :

www.devicemanuals.eu

Summary of Contents for 5000/3 SGP

Page 1: ... Pompe universelle NL Gebruiksaanwijzing Duopomp S Bruksanvisning Universalpump I Istruzioni per l uso Pompa Duo E Manual de instrucciones Bomba dúo P Instruções de utilização Bomba dupla DK Brugsanvisning Universalpumpe 5000 3 SGP Art 1471 GARDENA w w w d e v i c e m a n u a l s e u ...

Page 2: ... private use around house and garden The GARDENA Dual Pump can be used for pumping rainwater tap water or chlorinated swimming pool water The pump is fully submersible waterproof sealed and can be immersed in the liquid down to a depth of 9 m The GARDENA Dual Pump is not designed for continuous operation e g industrial application continuous circulat ing operation Corrosive easily combustible aggr...

Page 3: ... power Visual check Note on use Dry Running Liquid fails to flow The minimum flow rate is 80 l h 1 3 l min Watering accessories with lower rate must not be operated If the pump is operated for prolonged periods of time 5 min with the delivery side closed the water in the pump may heat up so that there is a risk of scalding yourself with hot water v The pump should not run against the closed delive...

Page 4: ...ation The specified maximum Pump is not filled and suction 1 Fill the pump using the filler self priming height is not hose is not held upwards neck until it overflows 2 Hold the suction hose up wards during the self prim ing phase so that the liquid you are going to pump cannot flow out of the pump via the suction hose 14 G Pumping liquid Freeing the impeller 8 9 5 1m 4 Operation When setting up ...

Page 5: ...7 Suction filter or backflow v Clean filter or back flow preventer clogged preventer Impeller blocked v Free the impeller Pump motor doesn t start No power v Check fuses and electric or suddenly stops connections Thermal overload switch v Free the impeller and open has cut out the pump due the pressure side to overheating overloading Impeller clogged v Send the pump to one of our GARDENA Service C...

Page 6: ... 2 EN 60335 1 EN 60335 2 41 Noise level measured 66 dB A guaranteed 69 dB A Year of CE marking 2002 Ulm 09 07 2002 Thomas Heinl Technical Dept Manager If a fault occurs with your Dual Pump please return the faulty unit together with a copy of the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions We expr...

Page 7: ...Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Postbus 50176 1305 AD A...

Reviews: