For safety reasons we recommend that you always operate 
the Dual Pump via a residual-current device (DIN VDE 0100-702
and 0100-738).

v

Please contact your electrician.

In Austria, according to ÖVE B / EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and
equipped with firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage must not exceed
230 V.

In Switzerland mobile appliances which are used outdoors, 
must be connected via a residual-current device.

According to DIN VDE (German Electrical Engineers’ Associa-
tion) 0620, mains power cables must not have a smaller cross-
section than the rubber-sheathed cables of the designation 
H07 RNF. The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of
the mains supply.

v

Take care that the electrical connections are made within 
dry area, protected from flooding.

Protect plug and power cable from heat, oil and sharp edges.

v

Don’t use the power cable for plugging off.

The power cable must not be used for mounting or relocating
the pump. For submerging or lifting / securing the pump, fix a
rope (available from GARDENA Service) to the pump’s carrying
handle.
Extension cables must meet the requirements of DIN VDE 
0620.

v

Before operating the pump, first make a visual check, if there 
is any damage of the pump (esp. regarding power cable and
plug).

v

Observe the minimum water level and the max. delivery 
height (see 9. Technical Data).

A damaged pump must not be used.

v

In case of damage, please have the pump checked by our
GARDENA Service Centre.

v

Clear the outlet line before use.

When setting up the pump for use out of water 

In order to avoid dry-running of the pump, take care that the 
end of the suction hose is always submerged into the liquid.

v

Before each operation, fill the pump to overflowing with
approx. 2 l of the liquid to be pumped ! 

Sand and other abrasive substances in the liquid cause in-
creased wear and reduce the pump’s output.

v

Use a Pump Preliminary Filter if the water contains sand 
(Art. No. 1730 / 1731).

The pump should not run against the closed delivery side 
for more than 5 minutes.

v

If liquid fails to flow, switch off the pump immediately.

In Austria 

In Switzerland 

Mains power 

Visual check 

Note on use 

Dry-Running 

Liquid fails to flow

The minimum flow rate is 80 l / h (= 1.3 l / min).
Watering accessories with lower rate must not be operated.

If the pump is operated for prolonged periods of time (> 5 min)
with the delivery side closed, the water in the pump may heat up
so that there is a risk of scalding yourself with hot water.

v

The pump should not run against the closed delivery side for
more than 5 minutes.

v

If liquid fails to flow, switch off the pump immediately.

Minimum flow rate 

Hot water – 
risk of scalding  

3. Initial Operation 

1. When setting up the pump 

for use underwater,

screw

the 

filter

1

onto the connection 

2

at the inlet side of the pump.

– or – 

When setting up the pump 

for use out of water,

connect a

vacuum-resistant suction hose 

3

with filter 

to the connec-

tion 

2

at the inlet side of the pump and screw on so that the

connection is air-tight.

2. When setting up the pump 

for use out of water

with suction

heights over 4 m, the suction hose should also be secured (fas-
tened to a wooden peg for example).
The pump is relieved of the weight of the suction hose.

Don’t use any hose connection system fittings on the suction
side ! A vacuum-resistant suction hose must be used 

e.g. GARDENA Suction Unit, 

art. no. 1411.

In order to reduce the suction time, it is advisable to use a suction
hose with backflow preventer avoiding automatic draining of the
suction hose when the pump is stopped.

Both pump connectors 

4

are equipped with a 33.3 mm (G 1

)

thread to which 13 mm (1/ 2

), 19 mm (3 / 4

) and 16 mm (5 / 8

)

hoses can be connected by using GARDENA hose connection
system fittings.

Best results regarding the delivery capacity of the pump are 
achieved when connecting 19 mm (3 / 4

) hoses in conjunction 

with e.g.

GARDENA Pump Connection Set, 

art. no. 1752,

or when using 25 mm (1

) hoses with fittings available from your 

sanitary dealer.

v

Connect the pressure hose 

5

to the connector 

4

on the 

delivery side.

Only when setting up the pump for use out of water :

V

Before each operation, fill the pump to overflowing 

A

with approx. 2 l of the liquid to be pumped ! 

1. Unscrew the screw fitting 

6

of the filler cap 

7

by hand.

2. Fill the pump via the filler cap 

7

to overflowing with approx.

2 l of the liquid to be pumped.

3. Tighten the screw fitting 

6

of the filler cap 

7

by hand (do not

use pliers).

Connecting a filter or 
hose to the inlet side :

Connection hose 
to delivery side :

Filling 
the pump :

6

7

2

1

5

4

2

3

www.devicemanuals.eu

Summary of Contents for 5000/3 SGP

Page 1: ... Pompe universelle NL Gebruiksaanwijzing Duopomp S Bruksanvisning Universalpump I Istruzioni per l uso Pompa Duo E Manual de instrucciones Bomba dúo P Instruções de utilização Bomba dupla DK Brugsanvisning Universalpumpe 5000 3 SGP Art 1471 GARDENA w w w d e v i c e m a n u a l s e u ...

Page 2: ... private use around house and garden The GARDENA Dual Pump can be used for pumping rainwater tap water or chlorinated swimming pool water The pump is fully submersible waterproof sealed and can be immersed in the liquid down to a depth of 9 m The GARDENA Dual Pump is not designed for continuous operation e g industrial application continuous circulat ing operation Corrosive easily combustible aggr...

Page 3: ... power Visual check Note on use Dry Running Liquid fails to flow The minimum flow rate is 80 l h 1 3 l min Watering accessories with lower rate must not be operated If the pump is operated for prolonged periods of time 5 min with the delivery side closed the water in the pump may heat up so that there is a risk of scalding yourself with hot water v The pump should not run against the closed delive...

Page 4: ...ation The specified maximum Pump is not filled and suction 1 Fill the pump using the filler self priming height is not hose is not held upwards neck until it overflows 2 Hold the suction hose up wards during the self prim ing phase so that the liquid you are going to pump cannot flow out of the pump via the suction hose 14 G Pumping liquid Freeing the impeller 8 9 5 1m 4 Operation When setting up ...

Page 5: ...7 Suction filter or backflow v Clean filter or back flow preventer clogged preventer Impeller blocked v Free the impeller Pump motor doesn t start No power v Check fuses and electric or suddenly stops connections Thermal overload switch v Free the impeller and open has cut out the pump due the pressure side to overheating overloading Impeller clogged v Send the pump to one of our GARDENA Service C...

Page 6: ... 2 EN 60335 1 EN 60335 2 41 Noise level measured 66 dB A guaranteed 69 dB A Year of CE marking 2002 Ulm 09 07 2002 Thomas Heinl Technical Dept Manager If a fault occurs with your Dual Pump please return the faulty unit together with a copy of the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions We expr...

Page 7: ...Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Postbus 50176 1305 AD A...

Reviews: