background image

GARDENA smart Pressure Pump

Contents:

 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

 2. SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

 3. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

 4. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

 5. MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

 6. STORAGE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

 7. TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

 8. TECHNICAL DATA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

 9. ACCESSORIES   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

10. SERVICE / WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

1. INTRODUCTION

Language

The initial language of these instructions is English. Other language ver­

sions are translations of the initial instructions.

Introduction:

This product may be used under supervision, or if instruction regard­

ing the safe use of the product has been provided and the resulting 

dangers have been understood, by children aged 8 and above, as 

well as by persons with physical, sensory or mental disabilities or  

a lack of experience and knowledge. Children must not be allowed to 

play with the product. Cleaning and user maintenance must not be 

performed by children without supervision. The use of this product  

by young  people under the age of 16 is not recommended.

Intended use:

The GARDENA smart Pressure Pump is intended for private use around the house  

and garden. It is primarily intended for operating watering systems and systems  

in  private gardens. The product is correct for conveying rainwater, tap water and chlo-

rinated water.
The GARDENA smart Pressure Pump can only be programmed together with the 

 GARDENA smart Gateway Art. 19000.

 

The product is not intended for long term use (e. g. use for continuous 

 cir culation) in a pond. The length of life of the product will be shortened 

accordingly if used in this way. Corrosive, flammable or explosive sub­

stances  (e. g. petrol, paraffin, thinners), grease, oil, salt water, sewage  

and food intended for consumption must not be conveyed by the pump.  

The temper ature of the liquid conveyed must not exceed 35 °C.

Product description:

The GARDENA smart Pressure Pump is controlled automatically with 

the GARDENA smart system App.

ß

L1

 Watering LED / Error LED

• Green: Water flows 

• Off: Standby (when 

ß

L3

 lits) 

• Red flashing: Error occurs (see 7. TROUBLESHOOTING)

ß

L2

 Connection­LED

• Green flashing: Wait for connection

• Green – orange – red: signal quality

• Red flashing: Inclusion not done

Display:

Reset

L1

L2

L3

15

GB

Summary of Contents for 19080

Page 1: ...ure Pump I Istruzioni per l uso smart Pressure Pump NL Gebruiksaanwijzing smart Pressure Pump S Bruksanvisning smart tryckpump N Bruksanvisning smart trykkpumpe FI K ytt ohje lyk s painepumppu DK Brug...

Page 2: ...ssure Pump is intended for private use around the house and garden It is primarily intended for operating watering systems and systems in private gardens The product is correct for conveying rainwater...

Page 3: ...systems even with low water flow Error diagnosis system The pump comes with an error diagnosis system which shows differ ent fault statuses and their remedies via the GARDENA smart App 2 SAFETY Symbo...

Page 4: ...g the pump look and see if there is any damage to the pump especially to the power cable and plug v In case of damage please have the pump checked by our GARDENA Service Centre Personal safety WARNING...

Page 5: ...ystem is permanently installed appropriate shut off devices must be installed on the input and output sides Important for maintenance and cleaning work on the pump or for shutdown for example To conne...

Page 6: ...r supply rather than rigid piping Flexible hoses will reduces the noise level and prevent damage caused by pressure surges Install fixed pipes at an upward gradient on the first 2 m only 1 Put the pre...

Page 7: ...able amounts of liquid may escape Please keep a sufficiently large container at hand for collection 5 Tighten the lid 9 of the filter chamber up to the stopper a 6 Lift the pressure hose directly upst...

Page 8: ...e 4 OPERATION 1 2 w q To clean the check valve e r 1 If necessary close all the shut off devices on the intake side 2 Open all tapping points so that the pressure side is depressurised Now close the e...

Page 9: ...o loosen the impeller t A blocked impeller can be loosened again 1 Turn the motor shaft 15 with a screw driver This will loosen the blocked impeller 2 Start the pump see 4 OPERATION To clean the flow...

Page 10: ...he pump from the mains Problem Possible Cause Remedy Error LED flashes 1 time During the initial operation the pump did not suck water for 30 seconds Pump does not suck water Pump was not sufficiently...

Page 11: ...or overheated v Let the pump cool down for 20 min Error LED flashes 3 times During the current operation the pump did not suck water for 30 seconds Water supply disrupted on the suction side Problem o...

Page 12: ...onnect the mains plug Power failure v Check the fuse and the cables FI was triggered because a residual current was detected v Disconnect the pump and con tact the GARDENA Service Electrical interrupt...

Page 13: ...nnection Set Connection Set for 1 2 Pressure Hoses Art No 1750 GARDENA Pump Connection Set Connection Set for 3 4 Pressure Hoses Art No 1752 10 SERVICE WARRANTY Service Please contact the address on t...

Page 14: ...urve Courbe de performances Curva di rendimento Prestatiegrafiek Kapacitetskurva Ytelseskurve Suorituskykyk yr Ydelseskurve K ivka v konnosti Krivulja zmogljivosti Wykres wydajno ci 0 5 10 0 50 100 ba...

Page 15: ...geldt voor extra onderdelen en accessoires S Produktansvar Vi vill uttryckligen p peka att i enlighet med produktens ansvarsr tt vi inte ansvarar f r skada som orsakats av v ra produkter om skadan be...

Page 16: ...randering aan de apparaten verliest deze verklaring haar geldigheid S EU Tillverkarintyg Undertecknad firma Husqvarna AB 561 82 Huskvarna Sweden i ntygar h rmed att nedan n mnda produkter verensst mme...

Page 17: ...taja Bemyndiget repr sentant Autorizovan z stupce Poobla eni predstavnik Autoryzowany przedstawiciel Reinhard Pompe Vice President Harmonisierte EN Normen Harmonised EN Harmonisation EN Norme armonizz...

Page 18: ...wton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Como 72 23868 VALMADRERA LC Phone 39 0341 203 111 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo...

Reviews: