13
GB
5. Putting into operation
Connect the hose to the
Don’t use any hose connection system fittings on the suction side!
suction side:
A vacuum-resistant suction hose must be used
•
e.g. GARDENA Suction Unit,
Art. no. 1411
.
To shorten the time required for suction to start again, we recom-
mend the use e.g. of the GARDENA suction filter with backflow
preventer,
Art. 1728
, combined with the GARDENA suction hose,
Art. 1412
, which prevents the suction hose emptying automatical-
ly when the automatic domestic water systems are shut down.
➔
Remove the flat gasket of the suction hose and replace it with
the dirt filter
provided.
Alternatively, you can also use the GARDENA Pump
Preliminary Filter,
Art. no. 1730/1731
.
It is important to filter the water to prevent contaminating the
manometric switch.
Connect the hose to the
The 33.3 mm (G1) inner thread at the outlet of the Electronic
delivery side:
Manometric Switch can be modified if necessary to an outer thre-
ad by using the GARDENA Pump Fitting,
Art. No. 1745
, which
can be fitted to the GARDENA Water Hose Connection System.
For pumps fitted with an horizontal 33.3 mm (G 1) outer thread we
recommend the use of the GARDENA Brass Angle with inner thre-
ad,
Art. No. 7281
. The connections have to be sealed with com-
mercial agents.
6. Operation
Switch on Electronic
Warning ! Electric shock !
Pressure Switch:
Risk of injury due to electric shock.
➔
Disconnect the Electronic Pressure Switch from
the mains before filling it.
1. Turn rotary switch
of the non-return valve to
position 2
.
(valve opened).
2. Open filler pipe of pump (to vent it).
3. Fill with liquid to be pumped via the outlet pipe
until it
reaches the overflow.
4. Open any shut-off devices in the delivery line (watering acces-
sories, water stop, etc.) so that air can escape before the pri-
ming procedure begins.
5. Drain remaining water in pressure hose so that air can escape
during the suction process.
The mains plug of the pump must be plugged into the
manometric switch!
6. Switch ON/OFF switch of pump (if present) to
"ON"
.
7. Plug the pump into a 230 V/50 Hz alternating current socket
.
Warning: The pump will start immediately!
8. When the pump has begun pumping, turn the rotary switch
of the return valve to
position 1
(normal operating mode).
➔
If the pump does not deliver liquid after 7 minutes,
unplug the manometric switch
(see “8. Trouble
Shooting“).
www.devicemanuals.eu