12
GB
Operating states
Red POWER LED
is on
The pump is operating in the
normal operating mode
.
Green Pump ON LED
The pump is pumping. Once the pump has reached the max pump
is on
pressure, the pump switches off (the green
Pump ON
LED extin-
guishes) and the pump functions in the
normal operating mode
.
Green Pump ON LED
The delivery rate is too low at the
delivery side
(less than 90 l / h).
flashes slowly (1 x per second.)
The pump continues to pump for a moment then switches off. The
pump switches on again as soon as the pressure reaches the
switching pressure of approx. 2.2 bar (e.g. if there is a leak) -
or-
the pump is about to switch off after you have finished drawing off
water.
Green Pump ON LED
The flow rate on
the inlet side
is too low (below 300 l / h).
lashes quickly (4 x per second.)
The pump continues to run for approx. 40 seconds. If normal ope-
ration is not achieved during this time, the pump switches off and
the control unit changes to the “
automatic selfpriming mode
”.
Yellow ALARM LED
The amount of water is too low when restarting the pump.
flashes slowly (1 x per second.)
The pump runs through the first “
priming cycle
”. If the normal
operating mode is not achieved, the pump switches off and the
control unit changes to the “
automatic selfpriming mode
”.
Yellow ALARM LED
Alarm which indicates if the amount of water is too low when the
flashes quickly (4 x per second.)
pump is operating in the normal mode. The control unit changes
to the “
automatic self-priming mode
”.
Yellow ALARM LED
is on
The “
automatic self-priming mode
” is no longer active and the
unit is no longer supplying water (e.g. no water in the container or
borse or the filter is dirty).
Green Pump ON LED
and
Warning:
There is a leak in the pipe system. The pump switches
yellow ALARM LED
flash
on and off because of a leak. If the pump switches on and off
alternately
more than 7 times within 2 minutes, the control unit issues a war-
ning via flashing LEDs and the motor switches itself off.
4. Assembly
Fit pressure switch
The Electronic Pressure Switch provided with a 33.3 mm (G 1)
on the pump:
external thread on the input side
.
1. For GARDENA pumps: art.1422/1429/1432/1434/1438/1442
screw adapter
on to the pump and screw sealing cap
on
the side pressure connection.
2. Place pressure switch
on the pump.
3. Hold the pressure switch
with
one hand and screw the lower
rotating part
into the pump
as far as the stop.
4. When you reach the stop, turn
the non-return valve
anti-
clockwise (max. 1 turn) to the
position required.
5. Plug mains plug
of the pump
into the socket
of the pressu-
re switch
(behind the display).
www.devicemanuals.eu