11
GB
Extension cables
The Electronic Pressure Switch may only be
operated with 230 V / 50 Hz.
➔
Note mains voltage.
Pursuant to DIN VDE 0620, power cable as
well as extension cables must not have a
smaller diameter than rubber sheathed cables
described with letter symbols H07 RNF.
➔
Ensure that the plug and socket connections
are arranged in an area which cannot flood.
In Austria
In Austria, the electrical connections must be
made according to ÖVE-EM 42, T2 (2000)/1979
§ 22 based on § 2022. Pursuant to this regula-
tion it’s imperative to operate pumps for swim-
ming pools and garden ponds exclusively via
an isolating transformer.
➔
Please ask your electrician.
In Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a resi-
dual-current device.
Visual check
➔
Always inspect before use to ensure that the
equipment, especially the plug and the
cable, are not damaged.
A damaged unit must not be used.
➔
If damaged, have the Electronic Pressure
Switch checked by GARDENA Service or an
authorised electrician.
3. Function and Display
The Electronic Manometric Switch is equipped with an electronic
control unit with fixed programs. The electronic control unit is acti-
vated by pulses from the manometric switch and the flow recogni-
tion of the dry-running safety feature.
The manometric switch is set at the factory to a switching pressu-
re of approx. 2.2 bar. This setting cannot be changed. The dry-
running safety mechanism protects the pump against damage and
controls the time the pump continues to run against the closed
delivery side.
Explanation of terms
Normal operation
The pump has reached the maximum pump pressure and switches
off automatically.
Suction cycle
The pump attempts to resume
normal operation
after 4 minutes.
Automatic
After a fault, the pump’s electronic control unit makes three auto-
self-priming mode
matic self-priming attempts at different time intervals (after 1 hour,
(yellow ALARM LED flashes)
after 5 hours and after 20 hours) to restore
normal operation.
The
priming cycle
(see above) is used for each of these attempts.
RESET key:
You can switch the pump on again prematurely at any time by
pressing the
RESET
key. If the warning LED is flashing, however,
the pump can only be turned on again by unplugging the mains
plug and then plugging the plug back in again.
Electronic control display
RESET key:
Resets the pump after a fault occurs.
Red POWER LED:
Indicates that the pump is connected to the mains power supply.
Green Pump ON LED:
Indicates that the pump is pumping.
Yellow ALARM (No Water) LED:
Indicates a fault.