4. OPERATION

  

 DANGER! Risk of injury!

 

  Injury when the product starts accidentally.

 

 Disconnect the product from the mains before 

you fill the container.

Watering programs [ Fig. O1 ]:
The watering programs can be set by the rotary switch 

(11)

 

on the watering control. The watering duration is repeated 

at the set watering frequency.

Note:
Art. 1407: 
A drip head dropper has a flow rate of 

approx. 2 litres per hour.
Art. 13158: Each outlet of a drip tube has a flow rate  

of approx. 1.6 litres per hour.

To connect the drip heads to the supply pipes  

[ Fig.  I3 ]:

  

 CAUTION! 

 

The first drip head should be placed directly 

above the water surface in the container (see  

Fig. O2 / O3). This serves to ventilate the system 

and prevents any after-running of the water after 

the system has been switched off, especially in the 

case of drip heads located below the water level.

1. Cut off the supply pipe 

(3)

 vertically at the installation 

point of the drip head 

(5)

.

2. Slide the supply pipe 

(3)

 fully onto the connection of  

the drip head 

(5)

.

3. Slide the other end of the supply pipe 

(3)

 fully on the 

other connection of the drip head 

(5)

.

4. Repeat steps 1 to 3 until all drip heads 

(5)

 are 

 connected.

5. Slide the end cap 

(9)

 onto the free connection of the last 

drip head 

(5)

.

To assemble the pipe pegs [ Fig. O2 ]:
We recommend the assembly of 3 pipe pegs per 1 m long 

flower box.
1. Insert the tube holders 

(4)

 in the desired positions in the 

soil of the flower box.

2. Clamp the supply tube 

(3)

 into the pipe pegs 

(4)

.

Program table

Rotary switch 

position

Watering frequency and Watering duration

Litres per day and drip head /  

outlet approx.

OFF

No watering

Art. 1407

Art. 13158

One-time watering for 3 minutes

0.1 litres

0.07 litres

4 h 6 min

Every 4 hours for 6 minutes

1.2 litres

0.9 litres

6 h 6 min

Every 6 hours for 6 minutes

0.8 litres

0.6 litres

8 h 1 min

Every 8 hours for 1 minute

0.1 litres

0.07 litres

8 h 3 min

Every 8 hours for 3 minutes

0.3 litres

0.22 litres

8 h 6 min

Every 8 hours for 6 minutes

0.6 litres

0.45 litres

12 h 1 min

Every 12 hours for 1 minute

0.07 litres

0.05 litres

12 h 3 min

Every 12 hours for 3 minutes

0.2 litres

0.15 litres

12 h 6 min

Every 12 hours for 6 minutes

0.4 litres

0.3 litres

24 h 1 min

Every day for 1 minute

0.03 litres

0.02 litres

24 h 3 min

Every day for 3 minutes

0.1 litres

0.07 litres

24 h 6 min

Every day for 6 minutes

0.2 litres

0.15 litres

48 h 3 min

Every 2nd day for 3 minutes

0.05 litres

0.04 litres

48 h 6 min

Every 2nd day for 6 minutes

0.1 litres

0.07 litres

72 h 6 min

Every 3rd day for 6 minutes

0.07 litres

0.05 litres

To  start  the  watering  [ Fig.  O1 / O2 / O3 ]:

  

 CAUTION!

 

  Damage to the pump if it runs dry.

 

 Make sure that the container is always suffi-

ciently filled with water.

1. Fill the container with the previously calculated amount 

of water (make sure that the container in a secure 

 position).

2. Place the pump in the container filled with water  

(make sure that the pump is level with the bottom of  

the container).

3. Turn the rotary switch 

(11)

 to the OFF position.

EN

12

Summary of Contents for 1407

Page 1: ...konowych zbiornik na wod HU Haszn lati utas t s Erk lyl da nt z s nt z s b v t k szlet v ztart ly CS N vod k obsluze Zavla ov n na balkon Roz i uj c sada zavla ov n vodn n dr SK N vod na obsluhu Balk...

Page 2: ...D1 Art 1407 Art 1407 13158 3 x 2 x 1 x 3 x 24 x 15 x 1 x 10 m 4 5 6 7 8 9 5 1 2 3 I1 0 0 3 6 I2 6 3 7 O2 Art 1407 5 2 3 1 5 5 5 4 I3 3 3 5 9 5 O1 q O3 Art 13158 1 5 2 3 M1 w w w r w e 3...

Page 3: ...duct Read operator s manual General safety warnings Electrical safety DANGER Electric shock Risk of injury due to electric shock The product must be supplied through a residual current device RCD havi...

Page 4: ...o 25 plants when using one drip head per plant to be irrigated to a maximum length of 10 m With the accessories from the GARDENA Micro Drip System supply pipe pipe pegs and drip heads a max of 40 drip...

Page 5: ...of the flower box 2 Clamp the supply tube 3 into the pipe pegs 4 Program table Rotary switch position Watering frequency and Watering duration Litres per day and drip head outlet approx OFF No waterin...

Page 6: ...1 Disconnect the watering control 2 Clean the pump and the watering control see 5 MAINTENANCE 3 Store the pump and the watering control in a dry enclosed and frost free place Disposal in accordance wi...

Page 7: ...ARDENA service departments or specialist dealers approved by GARDENA 8 TECHNICAL DATA Pump Unit Value Art 1407 Art 13158 Rated Power W 24 Max delivery capacity l h 180 Max pressure bar 1 Max delivery...

Page 8: ...between these options This service is subject to the following provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser n...

Page 9: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 10: ...jujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origin...

Page 11: ...rmidade com as diretrizes uniformizadas da UE os padr es de seguran a da UE e os padr es espec ficos do produto Este certificado deixa de ser v lido se as unidades forem modificadas sem a nossa aprova...

Page 12: ...nstala ie de udare a balconului Set de extindere pentru instala ia de udare rezervor de ap R du kastmiss steem Kastmise laienduskomplekti veeanum Balkono laistymo sistema I pl stinis rinkinys su laist...

Page 13: ...a husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojim...

Reviews: