10
GB
Assemble the Irrigation Valve
9 V / 24 V (Art. 1251 / 1278) :
Connecting Watering
Valves 24 V (Art. 1278) :
H
G
H
F
D
0
B
7
C
8
9
E
Art. 1280
E
Art. 1280
V 3 : Close open distributor
output :
A
8
0
9
If you are only installing 2 valves in a Valve Box
V 3
, the open
distributor output must be sealed with an end cap.
1. Push the short telescopic pipe
8
into the open distributor
output.
2. Insert the securing clip
9
into the holes of the distributor
output
0
.
The flushing pipe
8
is fixed in place.
3. Screw the cover cap
A
onto the short telescopic pipe
8
.
Attention ! Flow direction !
A
V
Pay attention to the flow direction (arrows) when
assembling the Irrigation Valve
C
.
1. Push the long telescopic pipe
B
all the way into the nipple
on the outlet-side
7
.
2. Screw the short telescopic pipe
8
i
nto the inlet side of the
Irrigation Valve
C
.
The arrows on the Irrigation Valve point in
the flow direction.
3. Push the Watering Valve with the short telescopic pipe
8
into
the distributor output
0
.
4. Screw the long telescopic pipe
B
into the outlet-side of the
Irrigation Valve
C
.
5. Insert the securing clip
9
into the holes of the distributor out-
puts
0
and the connections
7
.
The telescopic pipes
8
/
B
are fixed in place.
When you open the box lid
D
you can see the flow direction
marked by the arrows on the Irrigation Valve
C
.
You can connect up to 12 Watering Valves
Art. 1278
(24 V) to the
Watering Controller 4040
Art. 1276
using the Connection Cable
Art.
1280
in combination with the expansion module 2040
Art. 1277
.
1. Guide the connection cable
E
into the side of the Valve Box
V 3
and attach to the terminal strip
F
according to the outputs of
the watering controller (refer to colour of cable).
2. Screw one cable from each valve into the connections
C
.
3. Screw the other cable from
each valve into the connec-
tions
1– 6
according to the
routing of the cables.
4. If you are using 2 Valve
Boxes of model
V 3
, connect
the second Valve Box
V 3
to
the first Valve Box
V 3
using
the connection cable.
5. Push the protective cap
G
over the terminal strip
F
and tighten
both screws
H
.
Please refer to the operating instructions for the
Programming
Unit Art. 1242
for instructions on how to connect the
Watering
Valves Art. 1251
(9V) to the
Controllers Art. 1250
.