background image

7

If you need advice, call us

 

FREE

 on 

0800 807 433

 

or email us at [email protected]  

If you choose to vary from these instructions your warranty will be impaired.

!

KITSET WOODEN FLOORS

Every shed must have a floor. These are available from your local shed dealer.
For more information visit www.gardenmastersheds.co.nz

FLAT FLOOR CLAMPS

For existing concrete only. 

Water can seep underneath.
Available from your local 

shed dealer.

BOXING DIAGRAM

20MM - 25MM

(1 ' X 1 ')

INTERNAL DIMENSIONS

APPROX 25MM RECESS  

AROUND THE OUTSIDE

25MM

2985MM

INTERNAL 

MEASUREMENT

2235MM

RUNNER

SHED

FLOOR BOARD

SHED

RECESS

20MM - 25MM

8MM BOLT SET INTO CONCRETE

100MM

25MM

25MM

APPROX

20MM - 25MM

2985MM X 2235MM

INTERNAL DIMENSIONS FOR THE GM3023

STEP 7:

 

COMPLETE YOUR SHED

RECESSED CONCRETE FLOOR PLAN FOR SPECIALLY  

POURED CONCRETE FLOORS: 

SPECIFICATIONS

Every shed must have some type of foundation between it and the ground. You can pour a concrete floor and use recessed floor 
clamps, use an existing concrete base with flat floor clamps or purchase a kitset wooden floor from your local shed dealer.

RECESSED FLOOR CLAMPS

For poured floors with a 

recess around the perimeter.
Available from your local 

shed dealer.

For extra protection in high wind areas 

put additional nails through the wall 

channels into the floor boards and also 

peg the shed bearers to the ground.

GARDEN MASTER TIP

Summary of Contents for GM3023

Page 1: ...begin to put it together ASSEMBLY INSTRUCTIONS YOU SHOULD HAVE TWO PACKAGES 1 cardboard package 1 channel pack TOOLS SUPPLIED 1 riveter 3 3mm double ended drillbit TOOLS REQUIRED Battery or electric...

Page 2: ...the channel into the pan of the sheet close to a rib Extra rivets should be fitted on the inside of the channel into the pan of the sheets in high wind areas It is critical that you remove the swarf...

Page 3: ...x 3025mm ridge beam B G I K STEP 2 ROOF 1 Join 4 B 1600mm sheets together same as the back 2 Cap sheeting with G 3000mm channels 3 Rivet the channels at every second rib but not the corners at this s...

Page 4: ...door sheet STEP 3 END WALLS 1 Join 3 C sheets together to create a gable end wall as shown 2 Cap the bottom of the sheets with an H 2255mm channel 3 Cap the angled top of the sheets with a 2290mm chan...

Page 5: ...1 x 740mm wide sheet with door jamb attached Door pre hinged to 740mm sheet with door jamb 2 x 3000mm channels 2 x 793mm door spacers A D E F J A Drill and rivet here B Drill through to the underside...

Page 6: ...tered with the center of the gable end walls Once the first half of the roof has been placed down drill and rivet through the L Flashing at each end of the roof Drill and rivet 150mm from the front or...

Page 7: ...R BOARD SHED RECESS 20MM 25MM 8MM BOLT SET INTO CONCRETE 100MM 25MM 25MM APPROX 20MM 25MM 2985MM X 2235MM INTERNAL DIMENSIONS FOR THE GM3023 STEP 7 COMPLETE YOUR SHED RECESSED CONCRETE FLOOR PLAN FOR...

Page 8: ...ifting You will soon get a feel for which side needs propping up Do not attempt to assemble panels in rain or windy conditions Make sure your foundations are squared and level before erecting panels I...

Reviews: