II.
Delivery Conditions
Every product can be harmed during transportation, even if well packed and
issued, so the transporter should know about these risks that can occur during
transport. A delivery list should be made, in which any damage made during
transportation should be registered. (Confirmation by registered letter to the
carrier within 48 hours).
III.
NF C15.100 Pool regulation
In volumes 0 and 1, only protective measure by TBTS (Article 411.1), with rated
current less than 12V AC or 30V DC, is admitted, and being the source of
Security outside the packages installed 0.1 and 2 (the unit has at least a degree of
protection IP X5).
In volume 2 (see Figures 702A and 702B), the devices should be: - Class II, in
the case of lighting,
- Class I and protected by a protective device for residual current, indicated or
equal to 30 mA,
- Fed through an isolating transformer, according to the provisions of paragraph
413.5.1
The device has at least one degree of protection IP X2.
h: unknown variable
v: volume
Note:
Dimensions can be measured, considering walls and isolated interposed walls.