RTCC LED lighting controllers - User Manual
Mode
Mode
name
Operation
16
D-Type
Latch
(dLA)
D-type latch. When a leading edge is received
on the trigger input, the gate input signal is
latched and is used to set the output.
17
RS Latch
(rLA)
Edge triggered RS latch. The output is set
when a leading edge is received on the trigger
input, and cleared when a leading edge is
received on the gate input.
9.2.1
Burst mode
In burst mode, an output is pulsed several times in response to a trigger.
The periods are timed (not encoder counts).
The following parameters are used:
Mode is 8 for burst mode
Gate Input specifies the number of pulses (1 to 250)
Pulse Width specifies the pulse width
Pulse Delay specifies the separation between the start of one pulse and
the start of the next.
9.3
Flags
Each output also has the following flags which specify other options. For
Ethernet commands, multiple flags can be set by adding the flag values
together.
Flag
value
Flag
name
Operation
when flag = 0
Operation
when flag = 1
1
I
Trigger off leading edge
of input.
Trigger off trailing edge
of input.
2
O
Output is normally low,
going high when
pulsing.
Output is inverted. It is
normally high, going low
when pulsing.
4
G
If a gate input is
specified, the input
must be high to enable
triggers.
If a gate input is
specified, the input
must be low to enable
triggers.
8
E
No Ethernet message.
Send message on
Ethernet when
triggered. See Section
9.3.1, Ethernet
message flag (E)
—
32
—