CL190/CL191 Lens Controller - User Manual
separating them with
<LF><CR>
and adding the
>
prompt after the final
command reply.
All commands comprise a code of two letters followed by any parameter
necessary. All spaces in the command are ignored.
Numeric parameters are separated by a comma (
,
). Time periods are
specified in milliseconds by default, but you can add ‘s’, ‘ms’, or ‘us’ to the
parameter to specify seconds, milliseconds, or microseconds. Current is
specified in amps by default, but you can add ‘A’ or ‘mA’ to the parameter
to specify amps or milliamps.
Note:
All parameters are specified in the ‘USA/UK’ format, where a half is
written as ‘0.5’ and not ‘0,5
9.4
General commands
Any changes you make using Ethernet commands are not saved
permanently until you send the
AW
command.
Report the CL190 firmware version
This command returns the firmware version running on the TR-
CL180. For example, typing:
VR
returns
CL190 (HW01) V001
Set continuous mode
This command sets the output to continuous mode and allows the
brightness to be set:
RS1,s
Where:
s
= optical power within the range of the lens
Set switched mode
This command sets the output to switched mode and allows the
optical power to be set:
RU1,a,i
Where:
a
=
the Active optical power within the range of the
connected lens.
i
=
the Idle optical power within the range of the
connected lens.
Set the trigger sense option flag
This command sets the flag for trigger sense:
RE1,m
—
19
—