Safety - English

3.1.1

 

PP600 – Safety

Please read this before using the PP600 family of products. If in doubt, contact
your distributor or Gardasoft Vision.

 Where  this  symbol  appears  in  the  manual,  refer  to  the  text  for
precautions to be taken.

3.1.2

 

Heat

The PP600 can get very hot. It should be positioned where personnel
cannot accidentally touch it and away from flammable materials.

Do  not  exceed  the  power  ratings  given  in  the  manual.  Note  that  at  the
maximum ratings the case temperature can reach 80

o

C.

If the output load is short circuited then the heat dissipated within the unit will
greatly increase, resulting in a further rise in temperature.

3.1.3

 

Electrical

The user must ensure that the potential difference between any combination of
applied  signals  does  not  exceed  the  supply  voltage.  WARNING:  Higher
voltages may cause a danger to personal health.

The PP600 does not have complete tracking isolation of inputs and outputs.

Transients caused by inductive loads must be suppressed external to the PP600.

The metal case is not connected to PSU 0v. This is a change from previous
revisions of the PP600.

3.1.4

 

General

The PP600 must not be used in an application where its failure could cause a
danger to personal health or damage to other equipment.

If  the  equipment  is  used  in  a  manner  not  specified  by  the  manufacturer,  the
protection provided by the equipment may be impaired.

Summary of Contents for PP600

Page 1: ...MANUAL PP600 PP602 PP610 PP612 LED Lighting Controllers Revision 13 Gardasoft Vision Ltd Units 1 2 Castle Acres Elsworth Cambridge CB23 4JQ UK Tel 44 1954 200343 Fax 44 1954 204343 Web www gardasoft...

Page 2: ......

Page 3: ...user must ensure that incorrect functioning of this equipment cannot cause any dangerous situation or significant financial loss to occur Gardasoft Vision Ltd and Gardasoft Products Ltd will not acce...

Page 4: ...Simple Set Up to make the PP600 supply a small continuous current to the LED unit Check that the LED unit illuminates Users who have a PP610 or PP612 should refer to the PP610 section and read how to...

Page 5: ...reatly increase resulting in a further rise in temperature 3 1 3 Electrical The user must ensure that the potential difference between any combination of applied signals does not exceed the supply vol...

Page 6: ...en Wird pro Kanal mit hohen Blitzspannungen und kurzen Blitzzeiten gearbeitet steigen die Temperaturen nochmals an 4 1 3 Elektrischer Betrieb Stellen Sie sicher dass die Spannungsdifferenz bei keiner...

Page 7: ...ree modes of operation are provided separately for each channel Continuous In continuous mode the output is a continuous current Selected Continuous In selected continuous mode one or both inputs can...

Page 8: ...Input disable level IPL IPL 1 V This is the voltage applied between the anode and cathode of each optically isolated input Output current per channel il 4A continuous or 10A pulsed Maximum allowed cur...

Page 9: ...affected by high temperatures The enclosure of the PP600 is used to dissipate power in the form of heat For this reason the material to which the unit is attached must be suitable preferably metallic...

Page 10: ...together Chose a PSU that limits its output current by design by setting the current limit on the supply if this feature exists or use fuses Remember to derate the fuse if mounted in an enclosure as t...

Page 11: ...ply connection On previous revisions of this product the case was connected to GND The input connector has connections as follows Screw Terminal ID Function IP1 Input 1 positive IP1 Input 1 negative I...

Page 12: ...ut to PP610 5 GND 8 1 3 PP602 and PP612 Japan Style Connector Refer to section 12 for details on connecting to Japan style lighting 8 2 Power Supply The PP600 has split power input connectors for the...

Page 13: ...nd connections and VS connections are commoned 8 2 2 Split Supply Applications It is possible to run the two channels and digital system from two or three separate supplies as shown below though this...

Page 14: ...he memory is cleared 9 3 Set Up Each channel of the PP600 can operate in three ways Continuous output The output current is fixed Selected continuous output One or both inputs can be used to select an...

Page 15: ...2 INPUT2 1 INPUT1 0 Current setting 3 SE12 INPUT2 1 INPUT1 1 Current setting 4 9 3 2 Pulsed Output The output is off by default When a trigger is received on one of the digital inputs the PP600 will...

Page 16: ...l The PP600 will then ensure that the current averaged over approximately 200ms to the LEDs does not exceed the rating If the rating is exceeded the output is turned off and the display shows EC 1 or...

Page 17: ...CON Use UP or DOWN to select the required current in amps Note that the units digit is flashing and that UP or DOWN change the value by one Pressing RANGE to make the tens digit flash causes the value...

Page 18: ...y two Pressing RANGE to make the tens digit flash causes the values to change by ten The hundreds and thousands digits can also be selected using range The PP600 is ready to pulse the output on a trig...

Page 19: ...ded Set Up allows all the features of the PP600 to be set up It is entered by holding the RANGE button down for one second In order for the whole range of timing values to be entered it is necessary t...

Page 20: ...mps Then press SELECT to set the output current The RANGE button changes which digit is altered Press SELECT Wait one second Press SELECT Wait one second Press SELECT Press SELECT Press SELECT Wait on...

Page 21: ...ress SELECT to set the pulsed current The RANGE button changes which digit is altered Press SELECT Wait one second Press SELECT Wait one second Press SELECT Press SELECT Press SELECT Wait one second U...

Page 22: ...command Some commands need the output or input channel to be specified For these the channel number either 1 or 2 immediately follows the two letter command Where more parameters are needed they consi...

Page 23: ...and has been issued 10 1 1 General Commands AW Save the settings to memory Syntax AW Once the settings are saved to memory they are then retained when the unit is switched off If this is not done chan...

Page 24: ...00ms using input 1 as trigger and a delay of 15ms with a debounce period of 20ms The result of the ST command will be 01 M 06 E 1000 V 0 2 25 7 500 1500 02 M 01 E 7000 V5350 0 D 15 0 P 0 10 P1 M 00 U...

Page 25: ...off the command Example of Continuous Output Mode Set a continuous current of 0 5A on output channel 1 RS1S0 Select continuous current RC1C0V500 Current 500mA 10 1 3 Selected Continuous Output Mode I...

Page 26: ...6 Use both inputs for selection RC1C0V0 2 Current0 0 25mA When input 1 is 0 and input 2 is 0 RC1C1V25 7 Current1 25 7mA When input 1 is 0 and input 2 is 1 RC1C2V500 Current2 500mA When input 1 is 1 an...

Page 27: ...needed leave the Ee off the command Example of Pulsed Mode Set output channel 2 to pulse a current of 5 35A for 100ms triggered by input 1 with a delay of 15ms a debounce period of 20ms and the maxim...

Page 28: ...e layout Connector Channel Use SKT9 1 12V lights SKT10 1 24V and HLV lights SKT12 2 12V lights SKT11 2 24V and HLV lights 12V lights always have a 2 pin connector 24V and HLV lights always have a 3 pi...

Page 29: ...nnel 1 and assume a trigger input signal of 5V The delays are about 8us shorter for a 24V trigger input The delays for channel 2 will be greater All times are in microseconds Programmed Actual timing...

Page 30: ...t again E 25 E 26 The PP600 is calibrated during manufacture This stored calibration has become invalid Make a note of the number and contact your distributor E 00 E 01 E 02 E 03 E 04 E 05 E 06 E 07 E...

Page 31: ...31...

Page 32: ...and PP600F range PP600F Range Same as the PP600 range but with fast pulsing Pulse delay from 10us to 9 9ms in 1us steps Pulse width from 1us to 9 9ms in 1us steps PP600F Lighting controller PP602F Lig...

Reviews: