18
9.3.7
Setting Up Pulsed Operation
Pulsed operation can be set up using Simple Set Up.
PP600 is ready
Use UP or DOWN
to select "PU 1" to
trigger from
INPUT1 or "PU 2"
to trigger from
INPUT2.
Use UP or DOWN to select the required delay in
milliseconds. Note where the decimal point is and
that the delay is set up in multiples of 20us.
Note that the "units" digit is flashing and that UP or
DOWN change the value by two. Pressing RANGE
to make the "tens" digit flash, causes the values to
change by ten. The "hundreds" and "thousands"
digits can also be selected using range.
The PP600 is
ready to pulse the
output on a trigger.
Use UP or DOWN
to select which
output channel to
set up - "CH1" or
"CH2".
Press and hold SELECT for one second
Press SELECT
Press SELECT
Set the pulse width in the same way as the delay
period.
Use UP or DOWN to select the required current in
amps. Use the range button as for setting the delay.
Press SELECT
Press SELECT
Wait one second
Wait one second
Press SELECT
Wait one second
Wait one second
Press SELECT