TRENCHER
TZ S
Use and maintenance instructions – Spare parts Via L.da Vinci,32/B
Rev. 01.2013 - EN (translation of the original instructions)
41
36034 Malo (VI) Italy
T E Z A
8.1.2- MAINTENANCE SHEETS AND REGISTRATION SHEETS
AUTHORISED OPERATORS MUST RECORD THE MAINTENANCE WORK PERFORMED ON THE
MACHINE IN THE RELATIVE REGISTRATION SHEETS (SEE FOLLOWING PAGES).
MAINTENANCE SHEET
N° 01
WORK POINT
ENGINE
TYPE OF OPERATION
CHECKING THE OIL LEVEL
EVERY DAY: OPERATION TO PERFORM WHEN OIL IS COLD
1) Remove the oil filling cap/level stick of the oil and clean the stick.
2) Fit the oil filling cap/level stick into the filler but do not tighten; remove it to check the oil
level.
3) If the oil level is near to or under the lower limit notch on the stick, top up with the
recommended oil (see Tab. 6) until the level reaches the upper limit notch (lower edge of
the oil filler hole). Do not overfill.
Put back the oil filling cap/level stick.
4) Record the operation on registration sheet N°01.
CONSULT THE ATTACHED HONDA ENGINE MANUAL
OIL CAP / LEVEL STICK
UPPER LIMIT
OIL FILLING HOLE
(lower edge)
LOWER LIMIT
FUEL FILLING HOLE
FUEL TANK
ELECTRIC STARTING
(pertinent types)
OIL CAP / LEVEL STICK
OIL DRAIN CAP