en
7. Maintenance
Interval
Action
Before each use
Check all components for damage and secure seating.
Check the safety valve for correct operation.
After each time the pressure
sprayer is used
Release the pressure, empty the liquid container and clean it care-
fully.
Once a year
Smear the seals at the nozzle and all the O-rings with Vaseline.
8. Faults
Fault
Possible cause
Action
Maximum pressure not
achieved.
Components not correctly
screwed tightly together.
Check that all components are
correctly seated, and screw
them tightly together if neces-
sary.
Uneven spray pattern
Nozzle blocked.
Unscrew the nozzle and clean it.
Container hard to open
Pressure in the liquid container
too high.
Use the safety valve to fully re-
lease the pressure.
9. Technical data
Size
VL1
VA1
VS1
Capacity
1.5 ltr
1.5 ltr
1.5 ltr
Maximum operating pressure
3 bar
3 bar
3 bar
Material of seal
EPDM
Viton
Viton
Spray head material
PP
PP
PA
Colour of liquid container
White
Steel blue
Black
10. Recycling and disposal
For disposal of liquids and disposal of the activated carbon an absorption operation, comply with
the national and regional regulations and with the instructions stated on the safety data sheet is-
sued by liquid manufacturer.
13