background image

CAREFULLY FOLLOW THESE INSTRUCTIONS. IT IS VERY IMPORTANT FOR THE SAFETY 

OF THE OPERATOR AND ALL OTHER CHILDREN OR BYSTANDERS. SAVE THESE INSTRUC-

TIONS. IT IS IMPORTANT TO: 

•  Check the blind in motion and keep children and bystanders far from it while in action.  
•  Frequently check if any loss of balance, signs of wear or damaged wires are shown.  
•  Do not use if any repairing or maintenance is needed.  
•  In case of installation in awnings keep a distance of at least 1.5 ft from it (completely open) and whatever fixed item nearby.  
•  The device is not intended to be used by anyone (including children) whose physical, sensory or mental capabili-  ties 

are reduced, or lacking experience or knowledge, unless they have been granted through the intermediary of a person 
responsible for their safety, supervision or instruction concerning the use of the device.  

•  Children should be supervised to ensure they do not play with the device and/or with fix control devices.  
•  The control devices installed in a fixed manner must be positioned in view.
•  The control devices installed in a fixed manner must be positioned in view.

ATTENTION

Damaged  electric  products  and  batteries  should  not  be  disposed  of  with  normal  household  waste. 
Make sure to drop them in special provided containers or at an authorized organiza- tion that will en-
sure they are recycled. 

IMPORTANT

- The motor is shipped in sleep mode

- The motor will need to be woken up in order for it to function

- Ensure the battery is fully charged prior to installation

- Motor is not shipped fully charged, the battery comes 30% charged from the factory

Frequency bands

868,30 MHz

Duty rating

6 min

Insulation class

III

Operating temperature 

0°C to +60°C

Protection rate

IP 20 (for indoor use only)

Motor diameter

25 mm

25 mm

25 mm

25 mm

28 mm

Motor lenght

535 mm

550 mm

350 mm

350 mm

370 mm

*WARNING: The internal regulator works up to 15VCC

2

XSDC3EX030W

XSDC3EX030B

XSDC3EX030BI 

XSDC3EX030BE 

XSDC3EX030BC

XSDC3EX226B 

XSDC3EX226BI 

XSDC3EX226BE 

XSDC3EX226BC

XSDC3EX128

XSDC3DX128

XSDC3ED128

XSDC3EX228

XSDC3DX228

XSDC3ED228

Type

12VCC power 

operated*

embedded 

Li-Ion battery 

(External battery 

for BE version)

embedded 

Li-Ion battery 

(External battery 

for BE version)

power operated

power operated

Power supply

12VCC

12VDC

12VDC

24VDC

24VDC

Torque

1.1 Nm

1.1 Nm

2 Nm

1.5 Nm

2 Nm

Speed

30 rpm

30 rpm

26 rpm

28 rpm

28 rpm

Power

15 W

15 W

18 W

22 W

25 W

Amps

1.40 A

(Stand-by 300 µA)

1.40 A

1.60 A

0.90 A

1.10 A

Max turns

70

70

70

35

35

Summary of Contents for SileoXS XSDC30

Page 1: ...XSDC30 EN ULTRA QUIET MOTORIZATION...

Page 2: ...and batteries should not be disposed of with normal household waste Make sure to drop them in special provided containers or at an authorized organiza tion that will en sure they are recycled IMPORTA...

Page 3: ...crown A and the motor drive wheel B on the motor WARNING for some of the smaller tubes you need to remove the stock bushing to install the appropriate crown A Measure the length L between the inner ed...

Page 4: ...and away from metal objects NOTES Cables which pass through a metal wall must be protected and isolated using a grommet or sleeve Attach cables with intent to prevent any contact with moving parts Lea...

Page 5: ...ving during shipping or assembling Wake up the motor click the push button on the head of the motor the motor makes 1 jog Activate sleeping mode click the push button on the head of the motor the moto...

Page 6: ...tor to an intermediate position inbetween the two desired limits The motor needs to move in the direction of the limit in order for the limit to be properly set Press and hold the PROG FC button on th...

Page 7: ...E INTERMEDIATE POSITION TO CHANGE THE UP LIMIT TO CHANGE THE DOWN LIMIT 1 1 2 2 3 3 From any point between the existing limits press and hold both the PROG FC button and the UP button until the motor...

Page 8: ...ion has completed the motor first makes a brief jog and after 5 seconds it makes an additional jog This operation will not work unless it makes both jogs Memory is now empty 15 5 1 Activate sleep mode...

Reviews: