background image

EG-8

 

When you have finished adjusting the direction of the lens, tighten the locking 

screw with a screwdriver.

 

Attaching the service monitor

Use the service monitor cable to check and adjust  camera direction, focus, 

and angle on a service monitor.

 

Adjusting the camera direction

The camera body is set in a tri-axial mounting allowing movement in the  

pan, tilt, and rotational planes.

 

Adjust the direction of the lens so it faces the subject.

Attention

● 

Using the camera in a near-horizontal position will show the camera cover 

on screen.

● 

Forcibly adjusting the camera to point in directions beyond the limits of 

the mounting may cause the cable to catch on internal components and 

damage the camera.

The service monitor is not supplied with 

this unit. Please have one ready.

350º Pan

350º Rotation

180º Tilt

Locking screw

Indicates the top 

of the camera

(US)ZC-D5000NTSC_0830.indd   8

2006/08/30   15:18:22

Summary of Contents for ZC-BNX4312NHA

Page 1: ... US ZC D5000NTSC_0830 indd 1 2006 08 30 15 18 14 ...

Page 2: ...odify the camera 11 If an abnormality should occur immediately turn off the power and consult your dealer This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Thank you for your purchase of this...

Page 3: ...d the body cover then twist the screwdriver To attach Align the corrugations on the camera body and body cover then push until you hear a click Coaxial video cable Body cover Camera body Inner cover Dome cover Coaxial video cable Line phase adjustment volume Self tapping screws M4 x 20 2 pcs Mode setting switch Power input terminal Surface mount cover D D N switch WSC switch This switch is for use...

Page 4: ...s available page EG 6 Be sure to use the adapter ring to attach the camera INSTALLATION AND ADJUSTMENT When using an AC24V 60Hz power source in the line lock mode Depending on the method of attachment page EG 5 EG 6 Installation and adjustment process Use the following steps to attach and adjust the unit Drilling holes in the ceiling wall Attaching the camera body Connecting the cables Page EG 7 S...

Page 5: ...ll as directed in step 1 then refer to Running cables on the exterior surface of the ceiling or wall on the right Drilling holes in the ceiling or wall Use the template included to mark out the position on the ceiling or wall where you want to install the unit When running cables through the interior of the ceiling or wall Use the template and drill two holes for screws Screw A used to attach the ...

Page 6: ... the template included to mark out the position on the ceiling or wall where you want to install the unit Use the template drill two holes for screws Screw B used to attach the adapter ring Then follow the perforations on the template and cut out a hole to embed the camera body Attention Double check to make sure that the sizes and positions of the holes are appropriate BEFORE drilling the holes A...

Page 7: ...ing switch Attention Do not alter the position of the mode setting switch marked FIX from its factory default setting 1 FIX Do not change the switch position from the factory setting 2 Flickerless FL ON Shutter speed to be fixed at 1 100 OFF Normal position 3 Backlight compensation BLC ON Set to this position when a strong light is in the back ground OFF Normal position 4 Synchronization Sync INT I...

Page 8: ...e pan tilt and rotational planes Adjust the direction of the lens so it faces the subject Attention Using the camera in a near horizontal position will show the camera cover on screen Forcibly adjusting the camera to point in directions beyond the limits of the mounting may cause the cable to catch on internal components and damage the camera The service monitor is not supplied with this unit Plea...

Page 9: ...in which you are using the unit The default position for the adjuster is in the center Adjusting the view angle focus and iris Move the lever to adjust focus and angle of view Attention When using the ZC D5550NHA adjust the focus when the dome cover in place so that the axis of the lens goes passes through the center of the dome cover as in the illustration below Axis of the lens Focus adjustment ...

Page 10: ...provide a bright picture even in very low light conditions Camera images are limited to black and white while this function is active The camera will automatically begin providing color images again when the environmental light in the area where the camera is installed becomes brighter ON Automatic Day Night switching Low light conditions black and white Normal light color OFF Color images only D ...

Page 11: ...ON 1 41 lx D D N OFF 0 94 lx D D N ON 30IRE 0 63 lx D D N OFF 0 42 lx D D N ON 0 73 lx D D N OFF 0 47 lx D D N ON S N ratio More than 50dB At minimum AGC gain Gamma characteristic 0 45 Sync System Internal synchronization INT Line Lock L L For 60Hz regions only Electronic shutter 1 60 sec fixed Flickerless OFF 1 100 sec fixed Flickerless ON White balance ATW Power supply AC24V 10 50Hz 60Hz 1Hz DC12V...

Page 12: ...096 1 0 US ZC D5000NTSC_0830 indd 12 2006 08 30 15 18 24 ...

Reviews: