Change IP from DHCP to Static 
Here you can select IP address mode from DHCP to Static: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Save to confirm selection.

Summary of Contents for VCOUNT700RP

Page 1: ...Instruction Guide Configuration of GANZ IP VCA counters with VCOUNT700RP unit Rev 05 2015 People CountingSystem ...

Page 2: ...3 1 1 Network settings IP address 3 1 2 Logging 3 2 Counter configuration 4 2 1 Data transmission to VCOUNT700RP server 4 2 2 HTTP Server on GANZ GXi devices 6 2 3 Setup of counters in Camera encoder 7 2 4 Setup of VCOUNT700RP Gates 8 2 5 Setup of VCOUNT700RP Reports 9 3 Network settings of VCOUNT700RP server 12 ...

Page 3: ...d to this unit by DHCP server To recognize IP address of VCOUNT700RP unit you can use any software available for network scanning purpose e g Advanced IP Scanner As you can see on above picture VCOUNT700RP unit was detected with factory set name Raspberry Pi and its IP MAC address is shown as well you can find also MAC address printed on label of VCOUNT700RP unit 1 2 Logging in To login to the VCO...

Page 4: ...P server In order to ensure proper data transmission flow in the system you need to setup VCA Event Configuration as below SETUP Event Configuration Event Profile for ZN VE series old VCA SETUP Event Configuration Event Rules for ZN XE ZS1 ZN1 series new VCA Please modify first profile profile0 accordingly or create a new one activating options listed below In the next window after pressing Modify...

Page 5: ...PEOPLE COUNTING SYSTEM CONFIGURATION INSTR MANUAL 040515 5 In section Second Event deactivate DI and DO Please note second event is not available for ZN XE ZN1 ZS1 series devices ...

Page 6: ...r to activate data sending from VCA device to the VCOUNT700RP server you need to define the IP address of the VCOUNT700RP server in VCA device In Address field menu Setup Event Configuration HTTP please enter the IP address of VCOUNT700RP unit port number 80 No logon information are requested Enable Append detailed information for ZN XE ZN1 ZS1 series devices as per below snapshot on the right ZN ...

Page 7: ... 2nd counting line A direction in2 B direction out2 Camera 1 the 3rd counting line A direction in3 B direction out3 etc The names of counters for next camera in the same system must be unique It s not allowed to keep the same names of counters in two different devices working in the same system E g if last counters of CAM 1 are named in5 out5 the first counters of CAM 2 have to be named in6 out6 V...

Page 8: ...g added counters PERCENT percentage of counters added into camera counting zone over counters added into cameras counting the total value of clients Select Save to confirm selection Once gate is added associate counter s to gate by Add a camera menu below window appears User has to select counter number Camera filed on below snapshot which refers to value identified by X in point 2 3 selecting IN ...

Page 9: ...by selecting A new set of into Gates drop down box as per below snapshot By default only All Gates report is available In order to select which Gates will be visualized into Report edit it selecting pencil beside gate name Gates are selected by dragging and dropping desired gates under Goals included menu as per below snapshot Select Save to confirm Report settings ...

Page 10: ...hly in order to visualized counters as needed It is possible to show report into browser in table or chart mode otherwise it is possible to export it to Excel by selecting desired view from Show menu as per below snapshot Here below some example different type of reports Hourly report of single day in table mode Hourly report of single day in chart mode ...

Page 11: ...PEOPLE COUNTING SYSTEM CONFIGURATION INSTR MANUAL 040515 11 Daily report of a week in table mode ...

Page 12: ...twork card it is enable with port number 10000 by using below command https ip_address 10000 Configuration interface enables you to select Static DHCP address Default settings of network card Username serwis Password serwisvcn After logging in you can see Maintenance Interface Please select Network Interfaces to display all network settings Network Settings Please edit eth0 option by double click ...

Page 13: ...PEOPLE COUNTING SYSTEM CONFIGURATION INSTR MANUAL 040515 13 Change IP from DHCP to Static Here you can select IP address mode from DHCP to Static Save to confirm selection ...

Page 14: ...PEOPLE COUNTING SYSTEM CONFIGURATION INSTR MANUAL 040515 14 CBC Poland sp z o o Anny German 15 01 794 Warszawa Tel 48 22 633 90 90 ...