background image

 
 

 

terminal of the blocking diode to the central pin of the cigarette lighter adapter. 

 

Use black wire to connect the negative terminal of the solar panel directly to the barrel of the cigarette 
lighter adapter. 

 

Plug in the cigarette lighter adapter. It will convert sunlight to electricity and charge the battery 
whenever it receives electricity 

 
 
5.  GSP Model Specifications 

 
 

5-1 Electrical Specifications 
 

Model 

GSP-6 

GSP-12 

GSP-30 

GSP-40 

GSP-55 

Maximum  power 
 [Pm]  

6W 

12W 

30W 

40W 

55W 

Maximum output 
 current [Imp]  

0.39A 

0.78A 

1.74A 

2.30A 

3.20A 

Maximum output 
voltage [Vmp] 

15.3V 

15.3V 

17.2V 

17.2V 

17.2V 

Short-circuit 
current [Isc]  

0.42A 

0.86A 

1.93A 

2.52A 

3.56A 

Open Circuit 
Voltage [Voc] 

19.2V 

19.3V 

21.6V 

21.6V 

21.6V 

NOCT  

45

±2

 

Max. System 
 voltage [V] 

120V DC 

Power tolerance 

+10% / -5% 

Temperature 
Coefficient of Isc  

+ 0.05 %/

 

Temperature 
Coefficient of Voc  

- 0.35 %/

 

Temperature 
Coefficient of Pm  

- 0.45 %/

 

Operating 
Temperature 

-40

 to 85

 

* Specifications are obtained under the standard test conditions of STC. 

(STC: Irradiance 1000 W/m2, Panel temperature 25 

, AM 1.5)  

* NOCT: Normal Operating Cell Temperature 

 

Summary of Contents for GSP-06

Page 1: ...el in a high traffic area where walking on them will be consistent 1 Introduction 1 1 General Introduction Thank you for choosing Ganz Eco Energy Semi Flexible Solar Panels With proper operation and m...

Page 2: ...5 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the solar output Although solar panels will produce some electricity in the shade it...

Page 3: ...solar panel unnecessarily during installation The panel surface may be hot There is a risk of burns and electric shock Do not unplug a connector if the system circuit is connected to an operating load...

Page 4: ...for annual performance and to eliminate seasonal adjustment use the table above 4 3 Wiring To ensure proper system operation and to maintain the warranty be careful to observe the correct cable conne...

Page 5: ...by short circuiting the battery Only use12 Volt Nominal battery banks that are rated to be Deep Cycle 4 6 Connecting the GSP Self Regulating Panels to 12V Battery Banks MODEL GSP 6 GSP 12 kit includes...

Page 6: ...harge controller for a single GSP 30 40 55W solar panel is The GANZ 4 5A charge controller GCC 4 5A Kit Wiring Instructions GSP Panels to GANZ 4 5A charge controller GCC 4 5A Kit to Battery 1 Ganz 4 5...

Page 7: ...Solar Panel systems are all unique and require expert design assistance Note By adding the voltage ratings of all the solar panels together will determine if you need to connect the panels in series...

Page 8: ...y negative one point ground Never ground the DC system to the boat bonding system or to any metallic part fixture or component on the boat Installations in RV s Caravans Ground the solar panel s to th...

Page 9: ...0 GSP 55 Maximum power Pm 6W 12W 30W 40W 55W Maximum output current Imp 0 39A 0 78A 1 74A 2 30A 3 20A Maximum output voltage Vmp 15 3V 15 3V 17 2V 17 2V 17 2V Short circuit current Isc 0 42A 0 86A 1 9...

Page 10: ...H W D mm 300 252 14 5 400 358 14 5 560 521 14 5 760 458 14 5 880 520 14 5 Weight 0 64 Kg 1 06 Kg 1 98 Kg 2 30 Kg 3 31 Kg Material of Cable PVC shielded cable with UV resistance Length of Cable 3m 2 1m...

Reviews: