background image

 
 

 

4-2 Panel Tilt Angle

 

 

Ganz Eco-Energy panels produce the most power when they are pointed directly at the sun. For installations 
where the solar panels are mounted to a permanent structure, the solar panels should be tilted for optimum 
winter performance. A tilted solar panel will allow for about 50% more daily power output than panels 
mounted horizontally. As a rule, if the system power production is adequate in the winter, it will be satisfactory 
during the rest of the year. The panel tilt angle is measured between the solar panels and the ground. 
 

 

 
Adjust the solar array to face true South (in northern latitudes), or true North (in southern latitudes). To 
optimize a fixed tilt angle for annual performance and to eliminate seasonal adjustment, use the table above: 

 
4-3 Wiring 

 
To ensure proper system operation and to maintain the warranty, be careful to observe the correct cable 
connection polarity when connecting the panels to a battery, controller (regulator) or to other solar panels.  
Recommended cable size is 16 AWG gauge.  
 
Red wire of output cable is positive, black wire of output cable is negative. 
 

 
 

 

 

 

 
 

 

 

 

 
 
 

 
 
4-4 Mounting the Solar Panel   

 

 

Since the use and applications will be varied, from fixed to motion based applications, the actual 
mounting process will depend on the application. 

 

 

The best method is to use the four mounting holes to be secured to some form of bracket or raised 
just above the surface 

(1/4” Minimum) to allow for circulation of air beneath the solar panel. 

 

 

Be aware of obstructions and heavy traffic areas, as they are not the best location for solar panels. 

 

Summary of Contents for GSP-06

Page 1: ...el in a high traffic area where walking on them will be consistent 1 Introduction 1 1 General Introduction Thank you for choosing Ganz Eco Energy Semi Flexible Solar Panels With proper operation and m...

Page 2: ...5 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the solar output Although solar panels will produce some electricity in the shade it...

Page 3: ...solar panel unnecessarily during installation The panel surface may be hot There is a risk of burns and electric shock Do not unplug a connector if the system circuit is connected to an operating load...

Page 4: ...for annual performance and to eliminate seasonal adjustment use the table above 4 3 Wiring To ensure proper system operation and to maintain the warranty be careful to observe the correct cable conne...

Page 5: ...by short circuiting the battery Only use12 Volt Nominal battery banks that are rated to be Deep Cycle 4 6 Connecting the GSP Self Regulating Panels to 12V Battery Banks MODEL GSP 6 GSP 12 kit includes...

Page 6: ...harge controller for a single GSP 30 40 55W solar panel is The GANZ 4 5A charge controller GCC 4 5A Kit Wiring Instructions GSP Panels to GANZ 4 5A charge controller GCC 4 5A Kit to Battery 1 Ganz 4 5...

Page 7: ...Solar Panel systems are all unique and require expert design assistance Note By adding the voltage ratings of all the solar panels together will determine if you need to connect the panels in series...

Page 8: ...y negative one point ground Never ground the DC system to the boat bonding system or to any metallic part fixture or component on the boat Installations in RV s Caravans Ground the solar panel s to th...

Page 9: ...0 GSP 55 Maximum power Pm 6W 12W 30W 40W 55W Maximum output current Imp 0 39A 0 78A 1 74A 2 30A 3 20A Maximum output voltage Vmp 15 3V 15 3V 17 2V 17 2V 17 2V Short circuit current Isc 0 42A 0 86A 1 9...

Page 10: ...H W D mm 300 252 14 5 400 358 14 5 560 521 14 5 760 458 14 5 880 520 14 5 Weight 0 64 Kg 1 06 Kg 1 98 Kg 2 30 Kg 3 31 Kg Material of Cable PVC shielded cable with UV resistance Length of Cable 3m 2 1m...

Reviews: