To avoid electric shock, fire, and injury, do not touch terminals while a panel is exposed to. Provide 
suitable guards to prevent direct contact with the solar panel output terminals. (Such as insulated 
tools and gloves). 

 

 

To avoid electric shock, fire, and injury, Avoid dropping or allowing objects to fall on panels. 

  

 

To avoid electric shock, fire, and injury, should not be allowed near the installation of solar panels. 

 

 

To avoid electric shock, fire, and injury, do not puncture or damage the back or front sheet of a panel. 

 

 

To avoid electric shock, fire, and injury, do not disassemble the panel, or remove any part installed by 
the manufacturer.  

 

 

To avoid electric shock, fire, and injury, do not use or install broken panels. 

 

 

Do not expose solar panels to mirrors, lenses or other forms of sunlight concentration or light 
enhancement.   

 

 

Under normal conditions, a solar panel is likely to experience conditions that produce more current 
and/or voltage than reported at standard test conditions. Accordingly, the values of Isc and Voc 
marked on this panel should be multiplied by a factor of 1.25 when determining component voltage 
ratings, conductor current ratings, fuse sizes, and size of controls connected to the solar output. 

 

 

Although solar panels will produce some electricity in the shade, it is always best to install panels 
where there is less shade and more exposure to direct sunlight.  

 

 

3. General Precautions 
 

 

3-1 General Safety Precautions 
 

 

Turn off inverters and circuit breakers immediately, when a problem occurs. 
 

 

Cover all panels in the panel array with an opaque cloth or material before making or breaking 
electrical connections.  
 

 

To avoid electric shock, fire, and injury, do not install the panel where flammable gases or vapors are 
present. As sparks may occur. 

 

 

If maintenance is necessary.

  

 

 
3-2 General Handling Precautions 

 

 

Remove all metallic jewelry prior to installing our panels to reduce the chance of accidental exposure 
to live circuits.  

 

 

Use insulated tools to reduce your risk of electric shock.  
 

 

Do not pull the output cable excessively. The output cable connection may become loose and cause a 
short circuit, open circuit or shock. 
 

 

 Do not scratch or hit the back sheet or front sheet to avoid damage.  
 

 

 Do not strongly rub the plastic surface of the panel because there is a possibility of the plastic film 
getting torn therefore causing an electric shock.  

Summary of Contents for GSP-06

Page 1: ...el in a high traffic area where walking on them will be consistent 1 Introduction 1 1 General Introduction Thank you for choosing Ganz Eco Energy Semi Flexible Solar Panels With proper operation and m...

Page 2: ...5 when determining component voltage ratings conductor current ratings fuse sizes and size of controls connected to the solar output Although solar panels will produce some electricity in the shade it...

Page 3: ...solar panel unnecessarily during installation The panel surface may be hot There is a risk of burns and electric shock Do not unplug a connector if the system circuit is connected to an operating load...

Page 4: ...for annual performance and to eliminate seasonal adjustment use the table above 4 3 Wiring To ensure proper system operation and to maintain the warranty be careful to observe the correct cable conne...

Page 5: ...by short circuiting the battery Only use12 Volt Nominal battery banks that are rated to be Deep Cycle 4 6 Connecting the GSP Self Regulating Panels to 12V Battery Banks MODEL GSP 6 GSP 12 kit includes...

Page 6: ...harge controller for a single GSP 30 40 55W solar panel is The GANZ 4 5A charge controller GCC 4 5A Kit Wiring Instructions GSP Panels to GANZ 4 5A charge controller GCC 4 5A Kit to Battery 1 Ganz 4 5...

Page 7: ...Solar Panel systems are all unique and require expert design assistance Note By adding the voltage ratings of all the solar panels together will determine if you need to connect the panels in series...

Page 8: ...y negative one point ground Never ground the DC system to the boat bonding system or to any metallic part fixture or component on the boat Installations in RV s Caravans Ground the solar panel s to th...

Page 9: ...0 GSP 55 Maximum power Pm 6W 12W 30W 40W 55W Maximum output current Imp 0 39A 0 78A 1 74A 2 30A 3 20A Maximum output voltage Vmp 15 3V 15 3V 17 2V 17 2V 17 2V Short circuit current Isc 0 42A 0 86A 1 9...

Page 10: ...H W D mm 300 252 14 5 400 358 14 5 560 521 14 5 760 458 14 5 880 520 14 5 Weight 0 64 Kg 1 06 Kg 1 98 Kg 2 30 Kg 3 31 Kg Material of Cable PVC shielded cable with UV resistance Length of Cable 3m 2 1m...

Reviews: