GAT ECO.Lock 7xxx F/ISO
Operation
38
HB_GAT-ECOLock-7xxxFISO--EN_12
www.gantner.com
► Within 5 seconds, press the button of the GAT ECO.Lock 7xxx F/ISO in using the first master data carrier for
approximately 1 second.
o
When the data carrier is read correctly, the LED is green for 2 seconds.
► Remove the master data carrier from the button.
o
The LED flashes green and red alternately. The second master data carrier can now be programmed.
► Repeat the process until all master data carriers are programmed.
► If a master data carrier is read for longer than 5 seconds during programming, the GAT ECO.Lock 7xxx F/ISO
automatically returns to the normal operating mode and the new master data carriers are saved in the lock.
5.4.2 Program Data Carrier
For lockers operating in personal locker mode, the program data carrier is used to authorize data carriers so that
they can be used with the locker. The program data carrier is also used to delete the existing authorizations of
personal lockers. See section “5.2.4. Personal Locker Programming Card Mode”.
5.4.3 Battery Data Carrier
After the batteries are replaced in the GAT ECO.Lock 7xxx F/ISO, the lock must be set back to the normal operating
mode using the battery data carrier. The internal action counter is reset to zero when the battery data carrier is
used. See section “4.1.3. Replacing the Batteries” for more information.
After replacing the batteries of a GAT ECO.Lock 7xxx F/ISO in personal locker mode, all settings stored in the
lock remain as previously configured.
5.4.4 Reset Data Carrier
The reset data carrier is used to delete all the master data carriers stored in a GAT ECO.Lock 7xxx F/ISO. See
section “5.4.1. Master Data Carrier”.
5.4.5 Service Data Carrier
The service data carrier is used to put the GAT ECO.Lock 7xxx F/ISO into configuration mode after the lock is
connected to a computer via USB (see section “4.2 USB Connection”). The settings of the GAT ECO.Lock 7xxx
F/ISO are configured using GAT C
onfig Manager while the lock is in configuration mode (see “6.
When the GAT ECO.Lock 7xxx F/ISO reads the service data carrier without being connected to a PC via USB
cable, an antenna calibration is performed, which locks the lock for a few seconds. After locking, the LED ring
flashes red and the service data carrier must be removed. The antenna is calibrated and the LED flashes green.
Finally, a green LED ring and a sound signal are emitted to indicate that the antenna calibration has been
completed successfully. The locker is then unlocked if it was locked before the calibration.
NOTE!
The service data carrier must be available for service employees who are required to configure the locker
system. Without the service data carrier, system configuration is not possible!