background image

GAT ECO.Side Lock 7000 BA / NW BA  
Installation

 

 

www.gantner.com

 

HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14

 

25

 

3.11  Installation in Lockers with Metallic Doors 

 

For lockers with metallic doors, the GAT ECO.Side Lock 7000 BA is mounted on the left or right inner locker wall 

depending on whether it is a right or left-hinged locker door. Two cutouts must be made in the locker door - one in 

the inner door sheet and one in the outer door sheet. The two parts of the GAT NET.Lock Bolt Set 7200 are then 

mounted into the locker door. See the diagram below and the following installation instructions. 

 

                                                                                                  

 

 

 

 

 

 

 

 

1.   GAT ECO.Side Lock 7000 BA 

2.   GAT NET.Lock Bolt Set 7200 

3.   3 x mounting screws for the GAT ECO.Side Lock 7000 BA  

5.   Door contact 

6.   4 x mounting holes for the GAT NET.Lock BoltSet 7200 

7.   LED position 

8.   Cutout for GAT NET.Lock Bolt Set 7200 

9.   Cutout for label carrier 

10. Label carrier 

 

 

Figure 3.11 - Installation in a locker with metallic, right-hinged door (dimensions in mm 

– inches shown in brackets) 

Summary of Contents for GAT ECO.Side Lock 7000 BA

Page 1: ...www gantner com HB_GAT GAT ECOSide Lock7000 BA EN_14 1 GAT ECO Side Lock 7000 BA NW BA Battery Powered Multi Technology Electronic Lock Installation Commissioning Operation Document Version 1 4 ...

Page 2: ...shall depend exclusively on the conditions of the guarantee Any further reaching claims are excluded and in particular the manufacturer accepts no liability for the completeness or accuracy of the contents of this manual The right is reserved to make alterations and alterations may be made at any time without prior notice being given Trademarks Attention is drawn at this point to markings and regi...

Page 3: ...bols intended to inform the user about potentially hazardous situations or important information for the safe and proper use of the described product s The safety messages also include directives on how to avoid hazardous situations These safety messages and directives must be read and observed The structure of the safety messages and the meaning of the symbols used in this manual are described in...

Page 4: ...he Signal Words Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates information considered important but not hazard related e g messages relating to property damage 4 Definition of the Safety Symbols Caution General Information This symbol indicates general warnings or cautions that are not related to a particular type of hazard Caution Electrical S...

Page 5: ...ance of the product must be carried out in accordance with the technical conditions of operation as described in the corresponding documentation Therefore it is essential to read the corresponding chapter of this manual and observe the instructions and information therein If there are still some points that are not entirely clear please do not take a chance All queries can be clarified by your GAN...

Page 6: ...f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inte...

Page 7: ...he GAT ECO Side Lock 7000 BA and GAT NET Lock Bolt Sets 20 3 10 Installation in Lockers with Non Metallic Doors Except Glass 22 Installation Requirements for the GAT ECO Side Lock 7000 BA and Non Metallic Doors 23 Installation Instructions for the GAT ECO Side Lock 7000 BA and Non Metallic Doors 24 3 11 Installation in Lockers with Metallic Doors 25 Cutouts in the Locker Door 26 Installation Requi...

Page 8: ...able 46 6 OPERATION 49 6 1 General 49 6 2 Target Group 49 6 3 Operating Modes 49 Free Locker Mode with or without Duration of Use Function 50 Free Locker Universal Mode 51 Free Locker Unique Number Mode 52 Personal Locker Programming Card Mode 52 Personal Locker Expiry Date Mode 53 6 4 GAT ECO Basic Set B BA 55 6 5 Summary of System Data Carriers 55 MASTER Data Carrier 55 OPEN MASTER Data Carrier ...

Page 9: ... the GAT ECO Side Lock 7000 BA into lockers with metallic non metallic and glass doors Chapter 4 COMMISSIONING describes how to put the GAT ECO Side Lock 7000 BA into operation and includes information on the battery and USB connection Chapter 5 CONFIGURATION describes how to configure the GAT ECO Side Lock 7000 BA using GAT Config Manager The main configuration settings for the lock are explained...

Page 10: ...e described tasks risk personal injury or damaging property equipment 1 5 Formatting Safety Critical Information The following formatting with example text is used in this manual to display important safety critical information that must be read and followed NOTE Following on from this signal word in the manual is a reference text that must be read and followed The reference text contains importan...

Page 11: ...et 7200 and for glass locker doors the GAT NET Lock BoltSet 7300 is available The bolt sets include a passive booster used to amplify the RFID reading field The GAT ECO Side Lock 7000 BA is powered by one 3 6 V AA battery which provides an operating life of up to 10 years at room temperature before requiring replacement The configuration e g operating mode of the GAT ECO Side Lock 7000 BA can be d...

Page 12: ...ordered separately if needed FID Company ID and Site Key The FID and site key are unique numbers assigned to every facility installation The site key is a combination of the FID and the read and write keys The site key is used in MIFARE and ISO 15693 systems and is encoded in every data carrier and device used in the facility thereby ensuring that data carriers from one installation cannot be used...

Page 13: ...E ISO ISO 15693 ICLS HID iCLASS The GAT ECO Side Lock 7000 BA has a multi technology RFID reader LEGIC advant that allows it to operate with a range of RFID technologies The information in this manual is applicable for the following technologies that can be used with the GAT ECO Side Lock 7000 BA UID and Segments LEGIC prime LEGIC advant UID ISO 15693 ISO 14443 MIFARE Classic 1k and 4k Ultralight ...

Page 14: ...GAT ECO Side Lock 7000 system 1 GAT ECO Side Lock 7000 BA NW BA 2 GAT NET Lock BoltSet 7100 3 GAT NET Lock BoltSet 7200 5 GAT NET Lock Tool 7000 6 GAT NET Lock Label GEA xxx Door labels in different designs For lockers with glass doors For lockers with non metallic doors 4 GAT NET Lock BoltSet 7300 8 GAT ECO Basic Set B BA For lockers with metallic doors 7 Battery Tadiran SL 860 S EU Tadiran TL 49...

Page 15: ...arked on the locker door 6 GAT NET Lock Label 7000 GEA xxx Self adhesive locker door labels in GANTNER design For metallic doors the label is stuck onto the label carrier For non metallic doors the label is stuck directly onto the door The labels are available for right and left doors and with or without printed locker numbers GAT NET Lock Label GEA right Part No 679034 For right hinged doors with...

Page 16: ...GAT ECO Side Lock 7000 BA NW BA General Information 16 HB_GAT GAT ECOSide Lock7000 BA EN_14 www gantner com ...

Page 17: ...ans who install the GAT ECO Side Lock 7000 BA Experience in mechanical work and basic electrical knowledge is required Previous knowledge of the GAT ECO Side Lock 7000 BA is not required 3 2 Definition of the Door Hinge Right of Left Door For installation it is important to determine whether the door is hinged to the left or the right This is defined as follows Figure 3 1 Locker door hinge definit...

Page 18: ... An installation checklist is available from GANTNER to assist with the test installation process 3 4 Metallic and Non Metallic Doors Because the RFID field of the GAT ECO Side Lock 7000 BA is distorted or blocked by metal e g metallic locker doors a cutout is made in metallic locker doors into which the GAT NET Lock Bolt Set 7200 and label carrier are installed A specific cutout for non metallic ...

Page 19: ...Transportation Guidelines The electronics of the GAT ECO Side Lock 7000 BA are activated when the locker door is pressed shut For factory produced lockers that use the GAT ECO Side Lock 7000 BA it is important to ensure the bolt set does not activate the lock s electronics during transportation or any time prior to delivery Activation of the lock electronics during transportation can decrease the ...

Page 20: ... door width allowed measured from the door shackle to the hinge is 230 mm 9 05 If the door is narrower the door shackle will hit the locker when the door is being closed Figure 3 4 Minimum door width Dimensions of the GAT ECO Side Lock 7000 BA and GAT NET Lock Bolt Sets Figure 3 5 Dimensions of the GAT ECO Side Lock 7000 BA dimensions in mm inches shown in brackets ...

Page 21: ...in mm inches in brackets Figure 3 7 Dimensions of the GAT NET Lock BoltSet 7200 dimensions in mm inches in brackets Figure 3 8 Dimensions of the GAT NET Lock BoltSet 7300 dimensions in mm inches in brackets 1 GAT ECO Side Lock 7000 BA 4 Status LED 2 Door shackle 5 Label carrier front cover on door outer side 3 Door contact 6 Metal support for glass door installation ...

Page 22: ...side of the locker door A drill hole is required in the locker door for the status LED See the diagram below and the following installation instructions For glass door installation instructions see 3 12 Installation in Lockers with Glass Doors 1 GAT ECO Side Lock 7000 BA 2 GAT NET Lock Bolt Set 7100 3 3 x mounting holes for the GAT ECO Side Lock 7000 BA the use of threaded sleeves is recommended 5...

Page 23: ...e bolt set and the front side of the GAT ECO Side Lock 7000 BA must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side Lock 7000 BA can potentially not function correctly If right and left hinged locker doors are in use together please note the correct LED position The GAT ECO Side Lock 7000 BA is mounted upside down on left doors in comparison to right doors F...

Page 24: ...n and snaps onto the lock Close the door so that the center points on the bolt gauge mark the hole positions onto the locker door inner side NOTE For doors made of softer material moderate pressure is sufficient For doors made of harder material press the door with sufficient force so that the drill markings are visible Remove the bolt gauge from the GAT ECO Side Lock 7000 BA Drill the three marke...

Page 25: ...door sheet and one in the outer door sheet The two parts of the GAT NET Lock Bolt Set 7200 are then mounted into the locker door See the diagram below and the following installation instructions 1 GAT ECO Side Lock 7000 BA 2 GAT NET Lock Bolt Set 7200 3 3 x mounting screws for the GAT ECO Side Lock 7000 BA 5 Door contact 6 4 x mounting holes for the GAT NET Lock BoltSet 7200 7 LED position 8 Cutou...

Page 26: ...uts in the Locker Door The following cutouts must be made on the inner and outer walls of the locker door in order to mount the GAT NET Lock BoltSet 7200 and label carrier The measurements for the cutouts are as follows Figure 3 12 Cutouts for metallic locker doors dimensions in mm inches shown in brackets ...

Page 27: ... measurement in Figure 3 11 The locker door the bolt set and the front side of the GAT ECO Side Lock 7000 BA must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side Lock 7000 BA can potentially not function correctly If right and left hinged locker doors are in use together please note the correct LED position The GAT ECO Side Lock 7000 BA is mounted upside dow...

Page 28: ...m x 94 mm 2 66 x 3 7 in the outer wall of the locker door for the label carrier 9 in Figure 3 12 Mount the bolt set onto the inside wall of the locker door using 4 screws NOTE Use pan head metal screws Ø 3 5 mm 0 14 screw length depends on locker door thickness The maximum tightening torque of the screws is 2 Nm 1 47 lb ft Push the label carrier onto the outside wall of the locker door The label c...

Page 29: ...of the locker door Furthermore a recess in the printing on the locker door or door label may be necessary for the status LED See the diagram below and the following installation instructions 1 GAT ECO Side Lock 7000 BA 2 GAT NET Lock BoltSet 7300 3 3 x mounting screws for the GAT ECO Side Lock 7000 BA 5 Door contact 7 LED position 12 Metal support for adhering the GAT NET Lock BoltSet 7300 the met...

Page 30: ...t and the front side of the GAT ECO Side Lock 7000 BA must be perpendicular and parallel to each other If not the door contact in the GAT ECO Side Lock 7000 BA can potentially not function correctly If right and left hinged locker doors are in use together please note the correct LED position The GAT ECO Side Lock 7000 BA is mounted upside down on left doors in comparison to right doors Figure 3 1...

Page 31: ...e glass adhesive to attach the GAT NET Lock BoltSet 7300 in the correct position to the inside of the glass door Observe the information in section 3 11 2 Installation Requirements for the GAT ECO Side Lock 7000 BA and Metallic Doors and the measurements in Figure 3 15 NOTE Before the mass production of lockers begins testing must be carried out by the locker manufacturer to ensure that the glass ...

Page 32: ...GAT ECO Side Lock 7000 BA NW BA Installation 32 HB_GAT GAT ECOSide Lock7000 BA EN_14 www gantner com ...

Page 33: ...n the number of locking cycles usage frequency of the lock and the environmental conditions The battery must be replaced when the battery voltage becomes too low If the battery becomes too weak the locker can no longer be locked The GAT ECO Side Lock 7000 BA indicates a weak battery state with five red flashes of the LED and five acoustic signals during a locking attempt NOTE For optimal battery l...

Page 34: ...k has already been used and the battery is being replaced the lock must be activated using the Battery data carrier see 4 2 3 Replacing the Battery After inserting the battery the GAT ECO Side Lock 7000 BA is in start up mode for approximately 2 minutes During this time the LED is solid green with a red flash every 4 seconds The LED switches off and a sound signal is activated when start up mode e...

Page 35: ...ing field o The internal counter in the GAT ECO Side Lock 7000 BA is reset and the lock returns to its normal operating mode 4 3 USB Connection A Micro B USB port is provided on the side of the GAT ECO Side Lock 7000 BA for computer connectivity The computers must run Windows operating system Windows 7 or newer The USB port location on the side of the lock allows configuration to occur while the l...

Page 36: ... for the first time the lock drivers are installed and the lock is automatically recognized If a driver is requested they are available on the Leisure Software USB stick which is included in the GAT ECO Basic Set B BA Hold the SERVICE data carrier next to the RFID reading field o The GAT ECO Side Lock 7000 BA enters into configuration mode The LED pulses green every 2 seconds to indicate this stat...

Page 37: ...ta carrier immediately after activating the antenna adjustment o The antenna adjustment process begins and the status LED flashes red for 5 seconds The process is complete when the LED flashes green for 1 second and the lock emits a beep It is possible to activate the antenna adjustment function even when the locker door is locked Antenna Adjustment via GAT Config Manager While configuring the GAT...

Page 38: ...GAT ECO Side Lock 7000 BA NW BA Commissioning 38 HB_GAT GAT ECOSide Lock7000 BA EN_14 www gantner com ...

Page 39: ...e Locker Sector number of the data on the data carrier and the time setting for limited duration of use function Date and time set automatically Unique numbers of the MASTER data carriers and OPEN MASTER data carriers if used The MASTER data carriers and OPEN MASTER data carriers can also be directly programmed into the GAT ECO Side Lock 7000 BA see section 6 5 1 MASTER Data Carrier However the mo...

Page 40: ...nd an existing project Alternatively click on the Create Project icon 2 in Figure 5 1 to start a new project Figure 5 1 GAT Config Manager project setup Once a project is established locations and sub locations for the project can be added to the Devices directory 2 in Figure 5 2 by clicking on the Add location button 1 in Figure 5 2 Figure 5 2 GAT Config Manager Add location To add a GAT ECO Side...

Page 41: ...connected GAT ECO Side Lock 7000 BA has been added to the Devices directory you can now view and adjust the configuration settings of the lock Complete the following steps to view the configuration settings Select the GAT ECO Side Lock 7000 BA from the Devices directory 1 in Figure 5 4 which is displayed here as GAT ECO Side Lock 7000 o The GAT ECO Side Lock 7000 BA is highlighted in blue Figure 5...

Page 42: ...T ECO Side Lock 7000 BA When you are finished configuring the GAT ECO Side Lock 7000 BA settings in GAT Config Manager it is important to finalize the configuration by uploading the file to the lock Complete the following steps to finalize the configuration Click on OK in the GAT Configurator Window Figure 5 5 o The following confirmation window opens Click Yes to apply the configuration to the lo...

Page 43: ...lar intervals Right click onto the GAT ECO Side Lock 7000 in the Devices tree and select Update Firmware Figure 5 6 Updating the GAT ECO Side Lock 7000 BA firmware o The Device update wizard opens where all available updates are listed Hover over the update version with the mouse to display the new features included with the update Select the most recent update then click on Next Figure 5 7 Device...

Page 44: ...he number of the locker where the GAT ECO Side Lock 7000 BA is installed can be defined The locker number setting is found here Configuration Operating mode General Locker number Enter the locker number for the GAT ECO Side Lock 7000 BA into the Locker number field Sound Signals The GAT ECO Side Lock 7000 BA has an integrated beeper that signals when locker activity takes place The sound signals s...

Page 45: ...sonal Locker without data carrier The functionality of locking personal lockers without data carriers allows the locker to lock automatically when the locker door is pushed shut without needing to use a data carrier The locker can be unlocked again using the data carrier s authorized to use the personal locker The function is found here Configuration Operating mode Personal Locker PreLock Personal...

Page 46: ... 1 1 2007 is not valid Boolean False LastOpenAtExpiredDate When this option is activated a locker can be unlocked one more time using the data carrier that locked it see 6 3 5 Personal Locker Expiry Date Mode Boolean True Free Locker Use TimeLimit Select the type of time limit for the locker see 6 3 1 Free Locker Mode with or without Duration of Use Function Duration or Point of time List option D...

Page 47: ...ring length This setting is not configurable Integer 6 LegicLocker Select the LEGIC locker List option Locker 1 Application Master cards Master Card 1 10 Fields to enter number for MASTER cards 1 to 10 and or OPEN MASTER data carriers Integer Read only parameter Production Article Num Article number of the device Integer Serial Num Serial number of the device Integer Manufacturer Num Manufacturer ...

Page 48: ...GAT ECO Side Lock 7000 BA NW BA Configuration 48 HB_GAT GAT ECOSide Lock7000 BA EN_14 www gantner com ...

Page 49: ...n case of operation problems 6 3 Operating Modes The GAT ECO Side Lock 7000 BA can function in one of the following operating modes Free locker with or without duration of use function Free locker universal Free locker unique number Personal locker programming card Personal locker expiry date Requirements for MIFARE and ISO 15693 data carriers All MIFARE and ISO 15693 data carriers that are used i...

Page 50: ...s exceeded the data carrier can no longer unlock the locker In this case the user must release their data carrier at an Info Terminal e g a GAT Info 6100 BA part no 858938 or a GAT Info 6150 BA part no 921323 NOTE This function is only possible with coded LEGIC advant data carriers and not possible with LEGIC prime data carriers In addition the GAT ECO Side Lock 7000 BA must be configured in GAT C...

Page 51: ...eeded and the locker cannot be opened anymore In this case the data carrier must be reset at a central station Release the locker door Free Locker Universal Mode Free locker universal operating mode differs from the standard free locker mode in the following ways Free locker universal mode allows the use of data carriers that are also used for other applications No validity date with free locker u...

Page 52: ...l locker using the PROGRAM data carrier included in the GAT ECO Basic Set B BA see section 6 4 GAT ECO Basic Set B BA Authorizing data carriers Close the locker door and hold it shut Hold the PROGRAM data carrier next to the RFID reading field o The information on the data carrier is read The GAT ECO Side Lock 7000 BA enters into programming mode o The LED flashes red until the PROGRAM data carrie...

Page 53: ...e general data block and the guest s personal locker number together with the expiry date valid from and valid to are written onto the locker data block of the data carrier Furthermore an index value is written onto the locker data block The valid from date must always be valid i e newer or equal to the date set in the GAT ECO Side Lock 7000 BA Upon first use of a locker the expiry date valid to d...

Page 54: ...thorized data carriers are no longer authorized to use the locker 4 has the same index value and a newer valid to date than in the lock o The index value and the new valid to date of the data carrier are saved in the lock The previously authorized data carriers are no longer authorized to use the locker NOTE Situation 2 is possible when the locker is locked or unlocked Situations 3 and 4 are possi...

Page 55: ...ock any GAT ECO Side Lock 7000 BA in a system If a user s data carrier is lost an emergency opening of the corresponding locker can be carried out using a MASTER data carrier Three MASTER data carriers are included in the Basic Set and they are only valid for the respective system NOTE The system operator must ensure that the MASTER data carriers are stored in a safe and secure location If a MASTE...

Page 56: ...ER data carrier is not included in the Basic Set and must be ordered separately if required This data carrier is only valid for the respective system NOTE The system operator must ensure that the OPEN MASTER data carriers are stored in a safe location that is secured against unauthorized access An OPEN MASTER data carrier can be used instead of an original MASTER data carrier To program the OPEN M...

Page 57: ...and the SERVICE data carrier must be removed The antenna is calibrated and the LED flashes green Finally a green LED and sound signal are emitted to indicate that the antenna calibration has been performed successfully The locker is then unlocked if it was locked before the calibration NOTE The SERVICE data carrier must be available for technicians who are required to configure the locker system W...

Page 58: ...irectly thereafter the following lock states are signaled by the LED LED Color Signalization Meaning 1 x orange flash Lock ready to read a data carrier 1 x red flash No authorization Error 1 x green flash Data carrier accepted Operation successful 1 x green flash Beeps ascending in pitch Battery replacement successfully completed Lock operating in the normal operating mode again Flashing red green...

Page 59: ... After every 1000 locking operations or If the locking function of a locker door is impaired Instructions Press the locker door shut o The door shackle must enter the corresponding opening in the lock centrally without touching the opening The door must close shut without increased effort Readjust the door see below if these conditions are not met o The GAT Lock Bolt Set must touch the front of th...

Page 60: ...T Lock Bolt Set must be replaced Adjust the position of the locker door according to the measurements in chapter 3 INSTALLATION If the door cannot be adjusted sufficiently install it in a different position If the door is damaged replace the door with a new door 7 3 Cleaning Regular cleaning of the locker components ensures that the locker system remains in good condition and the correct working o...

Page 61: ...nology RFID reader LEGIC advant Data carriers Segments and UID LEGIC prime LEGIC advant UID only ISO 15693 MIFARE ISO 14443 Classic 1k and 4k Ultralight DESFire EV1 and EV2 HID iCLASS 13 56 MHz Note It is recommended to have customer specific data carriers approved by GANTNER before use Reading field frequency 13 56 MHz Maximum sending power 500 mW Reading field range 5 to 35 mm 0 2 to 1 38 depend...

Page 62: ...tic PC halogen free V0 Color Dark gray Weight Approx 400 g 14 1 oz Dimensions 125 2 mm x 100 mm x 25 mm 4 93 x 3 94 x 0 98 Break in resistance capability DIN 4547 2 class C 8 7 Environmental Conditions Permitted ambient temperature 10 C to 55 C 14 F to 131 F Protection type IP 52 Protection class III Environment class based on VdS 2110 II conditions in indoor areas Compliance CE FCC IC ___________...

Page 63: ......

Page 64: ...4 16 T 61 29011 8114 info gantner com info gantner nl info aus gantner com London GB Bochum Germany Los Angeles USA T 44 1245 697588 T 49 234 58896 0 T 1 844 703 1139 info uk gantner com info de gantner com info us gantner com Ypern Belgium Dubai Middle East Ahmedabad India T 32 57 22 44 00 T 971 4 3333 466 info gantnerticketing com info gantner be info me gantner com Part No 837430 www gantner co...

Reviews: