background image

Electrical connections

TCP/IP with external power supply

4

www.gantner.com

Valid as from July 30

th

, 2013 • Technical data subject to modifications without notice! 

DB_GAT-ACCESS6100--EN_11.indd • PartNo.: 860279

Network

Ethernet, Connection via screw terminals.

Power supply

DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1. The power input is protected against reverse-polarity.

Recommended cables:

Ethernet: min. CAT 5 (STP) for 100 MBit

Wire colours

Ethernet 10/100 MBit

Connection to the device upper part

Attention: The socket (3) for the connection cable between the device
back part and the device upper part must be clean in order to guarantee
a good contact.

568A

568B

TX +

green/white

orange/white

TX -

green

orange

RX +

orange/white

green/white

RX -

orange

green

Relay output

For activation of devices like turnstiles etc.. The relay contact is of type 
NO (maker contact). Please observe the max. permitted switching voltages 
and currents (see technical data).
Depending on the connected instalation (e.g. turnstile) an additional free-
wheeling diode may be necessary, which is used to limit the switch-on 
current. Please read the documentation of the connected installation.

Optocoupler input

Input for status acquisition. For using the input a supply voltage must be 
applied. This voltage can be taken from the terminal‘s supply or from an 
external power source. Please observe the max. permitted input voltages 
and currents (see technical data).

GAT Access 6100

R

X +

TX

 -

TX

 +

GND

N

O 1

C 1

IN1 -

IN1 +

R

X -

VI

N +

TCP/IP

Power supply unit

e.g. GAT Power Supply SP014/1

V

Out+

GND

A

B

Mains power

Motor control

Feedback control

M

e.g. Turnstile

1

  Safety instructions

-  This device must be installed by qualified personnel only.
-  The applicable safety and accident prevention regulations 

must be observed.

-  Safety devices must not be removed.
-  Please observe the technical data of the device specified 

on the data sheet.

-  The device must be disconnected from the power supply 

prior to installation, assembly or dismantling.

Reviews: