background image

Electrical connections

TCP/IP with external power supply

4

www.gantner.com

GAT Access 6100

R

X +

TX

 -

TX

 +

GND

N

O 1

C 1

IN1 -

IN1 +

R

X -

VI

N +

TCP/IP

Power supply unit

e.g. GAT Power Supply SP014/1

V

Out+

GND

A

B

Mains power

Motor control

Feedback control

M

e.g. Turnstile

1

Valid as from July 31

th

 2013 • Technical data subject to modifications without notice! 

DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526

Power supply

DC supply (see technical data), e.g. via GANTNER GAT Power Supply 
SP014/1. The power input is protected against reverse-polarity.

Network

Ethernet, connection via screw terminals.

Recommended cables

Ethernet: min. CAT 5 (STP) for 100 MBit

Ethernet wire colours

Ethernet 10/100 MBit

Usage of the fingerprint reader GAT FR 055

The sensor field will light-up red if a finger print must be scanned.

Pay attention

 that the finger is always pressed vertically onto the sensor 

field in order to guarantee an optimal scanning of the finger! Furthermore 
the finger should be laid rectangular onto the sensor field and touch the 
top edge.
See also the operating instructions of the GAT Access 6100 F.

568A

568B

TX +

green/white

orange/white

TX -

green

orange

RX +

orange/white

green/white

RX -

orange

green

Connection to the device upper part

Attention: The socket for the connection cable between the device back 
part and upper part (circle with the lable (1) in the connection figure) must 
be clean in order to guarantee a good contact.

Relay output

For activation of devices like turnstiles etc.. the relay contact is of type NO 
(maker contact). Please observe the max. permitted switching voltages 
and currents (see technical data).
Depending on the connected installation (e.g. turnstile) an additional free-
wheeling diode may be necessary, which is used to limit the switch-on 
current. Please read the documentation of the connected installation.

Optocoupler input

Input for status acquisition. For using the input a supply voltage must be 
applied. This voltage can be taken from the terminal´s supply or from an 
external power source. Please observe the max. permitted input voltages 
and currents (see technical data).

Correct:

Incorrect:

  Safety instructions

-  This device must be installed by qualified personnel only.
-  The applicable safety and accident prevention regulations 

must be observed.

-  Safety devices must not be removed.
-  Please observe the technical data of the device specified 

on the data sheet.

-  The device must be disconnected from the power supply 

prior to installation, assembly or dismantling.

Reviews: