Mounting and installation instructions

1. Mounting holes

Drill mounting holes on a flat background (e.g. concrete wall) according to 
the following dimensional drawing. Use the three holes labelled (a).

2. Connection cable

The connection cables (power supply, network etc.) are run through the 
cable lead-ins of the GAT FR 055. With concealed/flush wiring (1) the 
connection cables are fed from behind via the back box. With surface 
wiring (2) the connection cables must lie in the cable duct on the back 
part of the GAT FR 055.

3. Wall mounting

Pay attention when fixing to an uneven background that the GAT FR 055 
housing and the device back part of the GAT Access 6100 F must not 
be distorted. Recommended mounting height: top edge of device 1.3 m.

1. GAT FR 055
2. Device back part of
   GAT Access 6100 F
3. Fastening screws
4. Connection cable
5. Connection cable GAT FR 055   
to GAT Access 6100 F
6. Weather protection cover
   (optional)
7. Fastening screws for weather
   protection cover

94.4 mm (3.72”)

60 mm (2.36”)

13 mm

(0.51”)

69 mm (2.72”)

20 mm
(0.79”)

Flush cabling

28.5 mm (1.12”)

71 mm (2.8”)

15

7 mm (6.18”)

14.1 mm (0.56”)

12.6 mm (0.5”)

a

a

a

4. Electrical connection

The connection cables (see (4) in previous drawing) are connected at the 
device back part of the GAT Access 6100 F (se page 4).

5. Mounting of the GAT Access 6100 F upper part

The connection cable of the GAT FR 055 (1) is fixed into the housing 
upper part of the GAT Acces 6100 F and the connection cable of the 
upper part (2) is fixed in the back part of the GAT Access 6100 F. After 
that the device upper part can be swung down into the back part (3).

Check the sockets (1) and (2)! Dirt, dust and humidity must be removed so 
that a good contact of the connection cable is guaranteed. No aggressive 
detergent may be used. Please do not damage socket contacts.
Attention: Cleaning only in powerless state!

6. Open the GAT Access 6100 F upper part

The GAT Access 6100 F an only be opened with the supplied special tool! 
With this the two catches on the bottom of the device can be unlocked in 
succession.

1

2

Bac

k b

ox

Maintenance

The sonsor field of the GAT FR 055 should be cleaned from time to time 
so that finger prints can be clearly scanned.

For cleaning the sensor field always use a humid (not wet!) smooth 
cloth. No sharp or acrid detergents and no sharp materials must be 
used!