Buck/Standard half bridge mode
CON1
Q1
CON2
Q2
VDC-
CON4
CON3
L
OUT
400V DC
+
VDC+
CON7
CON6
VSW
CON5
C
OUT
R
Load
This is standard half bridge configuration that can be used in
following circuits :
•
Synchronous Buck DC/DC
•
Single phase half bridge inverter
•
ZVS half bridge LLC
•
Phase leg for full bridge DC/DC or
•
Phase leg for a 3-phase motor drive
Jumper setting:
•
J4 (Q1): INT
•
J6 (Q2): INT_INV
Boost mode
CON1
Q1
CON2
Q2
VDC-
CON4
CON3
L
IN
VDC+
CON7
CON6
VSW
CON5
INPUT
VIN
When the output becomes the input and the load is
attached between VDC+ and VDC-, the board is
converted into a boost mode circuit and can be used for:
•
Synchronous Boost DC/DC
•
Totem pole bridgeless PFC
Jumper setting:
•
J4 (Q1): INT_INV
•