Gamry Instruments PTC1 Operator'S Manual Download Page 3

 

Limited Warranty 

Gamry Instruments, Inc. warrants to the original user of this product that it shall be free of defects resulting from 
faulty manufacture of the product or its components for a period of one year from the original shipment date of 
your purchase. 

Gamry Instruments, Inc. makes no warranties regarding either the satisfactory performance of the cell kit or the 
fitness of the product for any particular purpose. The remedy for breach of this Limited Warranty shall be 
limited solely to repair or by replacement, as determined by Gamry Instruments, Inc., and shall not include 
other damages. 

Gamry Instruments, Inc. reserves the right to make revisions to the product at any time without incurring any 
obligation to install same on systems previously purchased. All product specifications are subject to change 
without notice. 

There are no warranties which extend beyond the description herein. This warranty is in lieu of, and excludes 
any and all other warranties or representations, expressed, implied or statutory, including merchantability and 
fitness, as well as any and all other obligations or liabilities of Gamry Instruments, Inc., including but not limited 
to, special or consequential damages. 

This Limited Warranty gives you specific legal rights and you may have others which vary from state to state.  
Some states do not allow for the exclusion of incidental or consequential damages. 

No person, firm, or corporation is authorized to assume for Gamry Instruments, Inc., any additional obligation 
or liability not expressly provided herein except in writing duly executed by an officer of Gamry Instruments, 
Inc. 

Summary of Contents for PTC1

Page 1: ...PTC1 Paint Test Cell Kit Operator s Manual Copyright 2017 Gamry Instruments Inc Revision 2 1 September 15 2017 900 00057...

Page 2: ......

Page 3: ...obligation to install same on systems previously purchased All product specifications are subject to change without notice There are no warranties which extend beyond the description herein This warr...

Page 4: ...astern Standard Time 877 367 4267 Toll free US Canada Only Replacement parts for this kit are available from Gamry Instruments Inc Optional parts may be available from Gamry Instruments or from third...

Page 5: ...Damage 5 Parts List 5 Assembly of the Cell Top 6 Important notes 6 Procedure 6 Requirements for Metal Samples 7 Chemical Compatibility 7 Cell Setup 8 Working Electrode Area 8 PortHole Electrochemical...

Page 6: ...ing This cell was originally developed by Dr Richard Granata of Lehigh University The PTC1 was designed for electrochemical impedance testing of flat coated metal specimens It can also be used for tes...

Page 7: ...Gamry should have replacement parts in stock Please retain the shipment s packaging material for a possible claim against the shipping company Parts List Please check the contents of your kit versus t...

Page 8: ...rs 2 Gently push the graphite counter electrode into the smaller of the two holes in the top 3 Insert the counter electrode until approximately 5 cm of the electrode extends below the top 4 Wet the ou...

Page 9: ...quire testing without the base Painted samples must have an area outside of the cell free from paint This area is used to make electrical contact with the sample Chemical Compatibility The O ring used...

Page 10: ...op with the reference and counter electrode already in place on the cell Make sure that the protective cap is removed from the reference electrode With the top lightly pressed into the cell body you s...

Page 11: ...ity of crevice corrosion Use a spatula or a round implement to press the edge of the tape firmly against the metal sample Place the cell body and O ring of the PTC1 on the PortHole mask so that the ex...

Page 12: ...not in use Use the small protective cap shipped with the reference to cover the electrode tip if you want to store the top dry Many chemists believe that reference electrodes should be stored immerse...

Page 13: ...8 damage 5 distilled water 10 electrode area iii 8 Electroplating Tape 470 9 KCl 10 maintenance iii 10 O ring 5 7 8 9 10 Parts List 5 PortHole iii 9 Problems ii reference electrode iii 6 8 10 sample m...

Page 14: ......

Page 15: ......

Page 16: ...734 Louis Drive Warminster PA 18974 Tel 215 682 9330 Fax 215 682 9331 www gamry com info gamry com...

Reviews: