Chapter 3: Unpacking and Installation--Unpacking 

 

3 - 2 

Unpacking  

When you receive your Faraday Shield, please verify that you have received the following items: 

Table 1 - Faraday Shield - Rev 1 (992-00164) 

Quantity 

Part number 

Description 

730-00119 

4 mm female banana socket, M4 male screw, insulated, black 

810-00121 

Faraday Shield - Bottom Panel 

820-00161 

Shelf, polypropylene 

820-00163 

Ring stand rod, 12 mm OD, 400 mm length, M6 

14 

835-00042 

Thumb screw, plastic, M4 x 10 mm, black 

850-00067 

Rubber bumper, 1 5mm OD, 15 mm height, M4 

966-00012 

Door Panel Sub-assembly 

966-00013 

Side Panel Sub-assembly 

966-00014 

Top Panel Sub-assembly 

988-00078 

Operator's Manual 

All panel sub-assemblies have their cable entry plates (P/N 810-00123) already pre-mounted. 

Initial visual inspection 

After you remove your Faraday Shield components from its shipping carton, check all parts for any signs of 
shipping damage. If any damage is noted, please notify Gamry Instruments, Inc. and the shipping carrier 
immediately. Save the shipping container for possible inspection by the carrier. 

Assembly  

Use flat and padded surface (e.g. carpet, cardboard, etc.) for assembling to avoid scratches. No tools are required 
to assemble or disassemble the Faraday Shield. 

1.

 

Connect side panel sub-assemblies 

 

each side panel has two pairs of quick-release hinges mounted 

 

snap together corresponding hinges of all three side panel sub-assemblies (966-00013) 

 

 

 

Summary of Contents for Faraday Shield

Page 1: ...Faraday Shield Operator s Manual...

Page 2: ......

Page 3: ...dard Time 877 367 4267 Toll Free US Canada Only We will be happy to provide a reasonable level of free support for registered users Reasonable support includes telephone assistance covering the normal...

Page 4: ...any obligation to install same on systems previously purchased All system specifications are subject to change without notice There are no warranties which extend beyond the description herein This wa...

Page 5: ...hecked and is believed to be accurate as of the time of printing However Gamry Instruments Inc assumes no responsibility for errors that might appear Copyrights Faraday Shield Operator s Manual copyri...

Page 6: ...iv...

Page 7: ...ature and ventilation 1 1 Environmental limits 1 2 Use with dangerous materials 1 2 Cleaning 1 2 Leakage inside 1 2 RoHS Compliance 1 3 Chapter 2 Introduction 2 1 About this manual 2 1 About the Farad...

Page 8: ...Copyrights Inspection...

Page 9: ...is not required Connection of the Faraday Shield to an earth ground when allowed may lower the noise seen in an electrochemical test This connection of the Faraday Shield to an earth ground is not a...

Page 10: ...tively you can use isopropyl alcohol Do not use a wet rag or allow fluid to enter the enclosure Do not immerse the Faraday Shield in any type of cleaning fluid including water Do not use any abrasive...

Page 11: ...Chapter 1 Safety Considerations RoHS Compliance 1 3 RoHS Compliance The Faraday Shield has been built using lead free components This equipment complies with the European RoHS initiative...

Page 12: ...om earth ground Adjustable plastic shelf for reducing capacitive effects Ring stand rod for mounting clamps various connectors or adapters to hold glassware cables or any other laboratory equipment No...

Page 13: ...Chapter 3 Unpacking and Installation Notational conventions 3 1 Chapter 3 Unpacking and Installation Front view of an open Faraday Shield...

Page 14: ...14 Top Panel Sub assembly 1 988 00078 Operator s Manual All panel sub assemblies have their cable entry plates P N 810 00123 already pre mounted Initial visual inspection After you remove your Faraday...

Page 15: ...bly to one side panel using the quick release hinges open the door and slightly lift up the front part of the bottom panel with its standoffs align front panel and connect other side using the quick r...

Page 16: ...g and Installation Assembly 3 4 5 Mount top panel sub assembly put top panel sub assembly on top side of cage use four thumb screws to attach 6 Interconnect side panels use four thumbs screws to conne...

Page 17: ...e panels at two different heights o place shelf on flanges upper or lower level and attach with six thumb screws o slightly open thumb screws and slide shelf to remove it 8 Adjust cable entry plates f...

Page 18: ...eld within an enclosed space make sure that the internal temperature within that space does not exceed the 45 C ambient temperature limit of the Faraday Shield Be particularly careful if a computer or...

Page 19: ...Chapter 3 Unpacking and Installation Physical location 3 7 Faraday Shield fully assembled The Faraday Shield is not designed for outdoor use...

Page 20: ...inch length 35 cm 13 7 inch height 41 7 cm 16 4 inch Door opening max width 28 8 cm 11 3 inch height 40 5 cm 16 inch Top opening max width 30 2 cm 11 8 inch length 30 2 cm 11 8 inch Cable opening max...

Page 21: ...Appendix A Specifications Physical location 3 9...

Page 22: ...tions notational 2 1 earth ground 1 1 environmental limits 1 2 inspection 1 1 leaks 1 2 operation 1 2 physical location 3 6 safety 1 1 service contract i shipping 1 2 shipping damage 1 1 specification...

Reviews: