Gamko FLEXBAR X/1HB Manual Download Page 9

Flexbar

21-1-2009

edda

Algemene installatie instructie

m

o

d

if

ic

a

ti

o

n

s

destination

Gamko Holding BV

Mon Plaisir 75

4879 AL Etten-Leur

Tel.(0)76-5087500

The Netherlands

name

drawing nr.

draftsman

date

196169

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blad 9 van 13

Driver Bar 1
(master)

Driver Bar 2
(slave)

Driver Bar 3
(slave)

Mode = 0

Mode = 0

1

0

0

Mode = 1

Mode = 0

1

0

0

1

0

0

6

1

0

1

0

0

1

0

0

Driver Bar 1
(slave 0)

L

E

D

 o

u

tp

u

1

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

2

(D

M

X

  

R

=

0

0

4

G

=

0

0

5

B

=

0

0

6

)

L

E

D

 o

u

tp

u

3

(D

M

X

  

R

=

0

0

7

G

=

0

0

8

B

=

0

0

9

)

L

E

D

 o

u

tp

u

4

(D

M

X

  

R

=

0

1

0

G

=

0

1

1

B

=

0

1

2

)

L

E

D

 o

u

tp

u

5

(D

M

X

  

R

=

0

1

3

G

=

0

1

4

B

=

0

1

5

)

L

E

D

 o

u

tp

u

6

(D

M

X

  

R

=

0

1

6

G

=

0

1

7

B

=

0

1

8

)

L

E

D

 o

u

tp

u

7

(D

M

X

  

R

=

0

1

9

G

=

0

2

0

B

=

0

2

1

)

L

E

D

 o

u

tp

u

8

(D

M

X

  

R

=

0

2

2

G

=

0

2

3

B

=

0

2

4

)

L

E

D

 o

u

tp

u

9

(D

M

X

  

R

=

0

2

5

G

=

0

2

6

B

=

0

2

7

)

L

E

D

 o

u

tp

u

1

0

(D

M

X

  

R

=

0

2

8

G

=

0

2

9

B

=

0

3

0

)

L

E

D

 o

u

tp

u

1

1

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

1

2

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

1

3

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

1

4

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

1

5

(D

M

X

  

R

=

0

0

1

G

=

0

0

2

B

=

0

0

3

)

L

E

D

 o

u

tp

u

1

L

E

D

 o

u

tp

u

2

L

E

D

 o

u

tp

u

3

L

E

D

 o

u

tp

u

4

L

E

D

 o

u

tp

u

5

L

E

D

 o

u

tp

u

1

L

E

D

 o

u

tp

u

2

L

E

D

 o

u

tp

u

3

L

E

D

 o

u

tp

u

4

L

E

D

 o

u

tp

u

5

L

E

D

 o

u

tp

u

1

L

E

D

 o

u

tp

u

2

L

E

D

 o

u

tp

u

3

L

E

D

 o

u

tp

u

4

L

E

D

 o

u

tp

u

5

Mode = 0

24V DC

41

24V DC

24V DC

24V DC

24V DC

24V DC

D

M

X

 i

n

D

M

X

 o

u

t

DMX address 0-0-1

DMX address 0-0-1

DMX address 0-0-1

DMX address 0-1-6

DMX address 0-0-1

DMX address 0-0-1

Controller

Gamko

example:
Driver Bar 2
(slave 0)

example:
Driver Bar 3
(slave 1)

External

DMX-

device

(master)

D

M

X

 i

n

D

M

X

 o

u

t

D

M

X

 i

n

D

M

X

 o

u

t

D

M

X

 i

n

D

M

X

 o

u

t

D

M

X

 i

n

D

M

X

 o

u

t

D

M

X

 i

n

D

M

X

 o

u

t

RJ45-RJ45 Ethernet patch cable (Cat5e)

XLR-RJ45 connection cable (008110192)

Mode switch
(see list)
Default = 5

                                         Gamko controller mode

X/ACLED1-A = mode 4 - manual colour lapse (master)

                                        controller controls colour and brightness

X/ACLED1-B = mode 5 - automatic colour lapse (master)

                                        controller controls cycle speed and brightness

                                          Demo mode

X/ACLED1-C = mode 6 - different colour (static) per segment (master)
                                          switch dmx address to 0-0-1 to select output nr1
                                          use controller to set colour

switch dmx address to 0-0-2 to select output nr2

                                          use controller to set colour

                             controller controls brightness

X/ACLED1-D = mode 7 - chasing light RGB (master)
                                         dmx address 0-0-1 fast cycle speed
                                         dmx address 9-9-9 slow cycle speed, etc.

                                        controller controls brightness

X/ACLED1-F = mode 8 - chasing light rainbow (master)
                                         dmx address 0-1-0 slow colourchange
                                         dmx address 9-9-0 fast colourchange, etc.

controller

 regelt intensiteit

                                         Slave mode

X/ACLED1-E = mode 0 - DMX15 (each segment individual) (slave)
                                          to synchronise colours of 2nd, 3rd, etc bars
                                          with first bar (master)
                                          or to manipulate colours with lighting computer

                                         no controller

X/ACLED1-E = mode 1 - DMX3 (all segments equal) (slave)
                                          to synchronise colours of 2nd, 3rd, etc bars
                                          with first bar (master)

or to manipulate colours with lighting computer

                                         no controller

Connecting and settings
RGB driver(s)

GB

RGB settings

Summary of Contents for FLEXBAR X/1HB

Page 1: ...nts next to X MU or X VS20 4 legs on open storage segments X OS 3 legs on all other segments pull tape to open box 4 9 10 21 22 27 28 33 X MU X 1HB X VS20 X VS00 Settings troubleshooting X ACLED1 Colo...

Page 2: ...through cable duct and down behind machinefront 1 Place trafobox bracket over condensor 2 Place trafobox Neatly tue up excess cables Check if all accessoires are working properly Lead cables through...

Page 3: ...ssoires such as LED CELS or heating wire remove 1 horizontal bottle drawer 2 drawer slides 3 machinefront and 4 cross beam 5 Remove screws from evaporator cover 6 Pull out unit approximately halfway M...

Page 4: ...et in slider profile Remove cap s 1 lead cables through the tubes into the segment 2 then out through slider profile 3 and back in through the previous made hole Mount cable duct profile Couple segmen...

Page 5: ...lation and place grommet 2 For LED place bracket provided with trafobox 3 Place trafobox and lead cables through grommet 4 Seal hole Connect trafobox Click conenctors in bracket Plug in connectors for...

Page 6: ...rs are blocked when closed 1 When equippedwith electrical accessories such as LED CELS or heating wire Lead wires through cable duct and out the cornerpiece 2 Place external trafobox Recommended order...

Page 7: ...Place cable duct covers horizontaly according to illustration above 4 Connect line cord in socket tie up cord to prevent loss during placement 5 Slide bar in place 6 Adjust feet to level out bar and...

Page 8: ...TBMU 1 X TBMU 2 X TBMU 3 X TBMU 4 X TBMU 5 X 1HB 1 X TB1 1 X TB1 2 X TB1 3 X TB1 4 X TB1 5 X VS20 1 X TBVS 1 X TBVS 2 X TBVS 3 X TBVS 4 X TBVS 5 X VS00 X TBEX 1 X TBEX 2 X TBEX 3 X TBEX 4 X TBEX 5 48...

Page 9: ...1 DMX address 0 0 1 Controller Gamko example Driver Bar 2 slave 0 example Driver Bar 3 slave 1 External DMX device master DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out RJ...

Page 10: ...ports cablecut when all of the above hasn t solved the problem replace part of cable harness Colour within one segment differs one or more colour within the LED is broken but still closes the power ci...

Page 11: ...screws from evaporator cover 6 Place unit bracket to remove unit 7 Disconnect main powersupply connector and pull out unit 8 Drill a hole 85mm in center of X 1HB at 355mm from front 9 Break out knock...

Page 12: ...n met scharniergat zie illustratie zorg ervoor dat de magneet uitlijnt met de 1 Connect reed switches in series 2 Make sure the gap between the reed switches and the magnet is not too big if necessary...

Page 13: ...LS 55 Keyswitch 013050129 Cuff round 013050129 Retaining nut 013050129 Relais block 013050130 2x improved assembly order keyswitch lock relais blocks wiring diagram relais blocks CELS keyswitch ATTENT...