Gamko FLEXBAR X/1HB Manual Download Page 6

Flexbar

21-1-2009

edda

Algemene installatie instructie

m

o

d

if

ic

a

ti

o

n

s

destination

Gamko Holding BV

Mon Plaisir 75

4879 AL Etten-Leur

Tel.(0)76-5087500

The Netherlands

name

drawing nr.

draftsman

date

196169

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blad 6 van 13

28

31

X/VS00

33

X/VS00

30

X/VS00

X/VS00

X/VS00

1

2

4

3

A

DETAIL A

I

II

B

DETAIL B

29

0

1

32

X/VS00

LED

CELS

(DMX)

230V AC

4 determine to which side the thermostat needs to be
accessible and, if necessary, mount in opposite direction
5 position X/VS00 to back and top of segment and fix with
self-drilling screws (3,5x9,5mm)

Couple other segments
Make a hole in the endpanel to exit copper, drain tubes and
electrics.

Make sure that the drain runs downward and no

drawers are blocked when closed

1 When equippedwith electrical accessories
(such as LED, CELS or heating wire)
Lead wires through cable duct and out the cornerpiece
2 Place external trafobox

Recommended order:
First both segments in between
X/VS00 is to be placed

1

th

          1 determine to which side the copper and electrics will
           leave the bar; bend and soler the copper
2 remove shelf support rails from X/VS00 when next to
drawer segment
3 remove drawers and slides in drawer segments

bend out

flap

place sealing tape
between X/EP and segment

Couple segments
Turn hexagon key (6mm) on all 4 hooks, clockwise on
outside, counter-clockwise from inside segment
2-way action: I hook (make sure they "hook" properly)
                      II pull (max. 4 "clicks")

Plug in connectors for LED (and DMX) in
the external trafobox.
Plug in connectorsfor CELS and 24V in the
junctionbox inside the trafobox

Neatly tie up excess cables

Check if all accessories are working properly

GB

Summary of Contents for FLEXBAR X/1HB

Page 1: ...nts next to X MU or X VS20 4 legs on open storage segments X OS 3 legs on all other segments pull tape to open box 4 9 10 21 22 27 28 33 X MU X 1HB X VS20 X VS00 Settings troubleshooting X ACLED1 Colo...

Page 2: ...through cable duct and down behind machinefront 1 Place trafobox bracket over condensor 2 Place trafobox Neatly tue up excess cables Check if all accessoires are working properly Lead cables through...

Page 3: ...ssoires such as LED CELS or heating wire remove 1 horizontal bottle drawer 2 drawer slides 3 machinefront and 4 cross beam 5 Remove screws from evaporator cover 6 Pull out unit approximately halfway M...

Page 4: ...et in slider profile Remove cap s 1 lead cables through the tubes into the segment 2 then out through slider profile 3 and back in through the previous made hole Mount cable duct profile Couple segmen...

Page 5: ...lation and place grommet 2 For LED place bracket provided with trafobox 3 Place trafobox and lead cables through grommet 4 Seal hole Connect trafobox Click conenctors in bracket Plug in connectors for...

Page 6: ...rs are blocked when closed 1 When equippedwith electrical accessories such as LED CELS or heating wire Lead wires through cable duct and out the cornerpiece 2 Place external trafobox Recommended order...

Page 7: ...Place cable duct covers horizontaly according to illustration above 4 Connect line cord in socket tie up cord to prevent loss during placement 5 Slide bar in place 6 Adjust feet to level out bar and...

Page 8: ...TBMU 1 X TBMU 2 X TBMU 3 X TBMU 4 X TBMU 5 X 1HB 1 X TB1 1 X TB1 2 X TB1 3 X TB1 4 X TB1 5 X VS20 1 X TBVS 1 X TBVS 2 X TBVS 3 X TBVS 4 X TBVS 5 X VS00 X TBEX 1 X TBEX 2 X TBEX 3 X TBEX 4 X TBEX 5 48...

Page 9: ...1 DMX address 0 0 1 Controller Gamko example Driver Bar 2 slave 0 example Driver Bar 3 slave 1 External DMX device master DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out RJ...

Page 10: ...ports cablecut when all of the above hasn t solved the problem replace part of cable harness Colour within one segment differs one or more colour within the LED is broken but still closes the power ci...

Page 11: ...screws from evaporator cover 6 Place unit bracket to remove unit 7 Disconnect main powersupply connector and pull out unit 8 Drill a hole 85mm in center of X 1HB at 355mm from front 9 Break out knock...

Page 12: ...n met scharniergat zie illustratie zorg ervoor dat de magneet uitlijnt met de 1 Connect reed switches in series 2 Make sure the gap between the reed switches and the magnet is not too big if necessary...

Page 13: ...LS 55 Keyswitch 013050129 Cuff round 013050129 Retaining nut 013050129 Relais block 013050130 2x improved assembly order keyswitch lock relais blocks wiring diagram relais blocks CELS keyswitch ATTENT...