Gamko FLEXBAR X/1HB Manual Download Page 1

Flexbar

21-1-2009

edda

Algemene installatie instructie

m

o

d

if

ic

a

ti

o

n

s

destination

Gamko Holding BV

Mon Plaisir 75

4879 AL Etten-Leur

Tel.(0)76-5087500

The Netherlands

name

drawing nr.

draftsman

date

196169

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

02/09 DMX + CELS

5611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blad 1 van 13

1

3

2

Remove packaging

To prevent scratches: do not use a knife or sharp
object

Sort segments by order (from left to right)

Mount legs:

Beware of overlapping legs!

- 4 legs on segments next to X/MU or X/VS20
- 4 legs on open storage segments (X/OS)
- 3 legs on all other segments

pull tape

to open box

4 - 9

10 - 21

22 - 27

28 - 33

X/MU

X/1HB

X/VS20

X/VS00

Se

troubleshooting

        X/ACLED1

       (Coloured

       E

qual LED)

006030694

013060019

Changing

direction

door

Postmix column

on X/1HB

1 - 3

34 - 39

X/TB (trafobox)

41

48

Connecting

heating wire

to prevent

condensation on frame

Connecting ergonomic

light

(X/ACLED4)

40

42

43 - 45

49 - 52

Placing X/TP

(thin

endpanel)

46 - 47

PlacingX/EP02
(thin endpanel)

53

Example:

X/EP04 (set)
X/2LG41
X/ACLED2
X/2RG41
X/ACLED2
X/MU
X/ACCELS1
X/ACLED1-B
X/3DHBA41
X/ACCELS3

CELS

54 - 58

no leg
close with
EPP plug

General

GB

Summary of Contents for FLEXBAR X/1HB

Page 1: ...nts next to X MU or X VS20 4 legs on open storage segments X OS 3 legs on all other segments pull tape to open box 4 9 10 21 22 27 28 33 X MU X 1HB X VS20 X VS00 Settings troubleshooting X ACLED1 Colo...

Page 2: ...through cable duct and down behind machinefront 1 Place trafobox bracket over condensor 2 Place trafobox Neatly tue up excess cables Check if all accessoires are working properly Lead cables through...

Page 3: ...ssoires such as LED CELS or heating wire remove 1 horizontal bottle drawer 2 drawer slides 3 machinefront and 4 cross beam 5 Remove screws from evaporator cover 6 Pull out unit approximately halfway M...

Page 4: ...et in slider profile Remove cap s 1 lead cables through the tubes into the segment 2 then out through slider profile 3 and back in through the previous made hole Mount cable duct profile Couple segmen...

Page 5: ...lation and place grommet 2 For LED place bracket provided with trafobox 3 Place trafobox and lead cables through grommet 4 Seal hole Connect trafobox Click conenctors in bracket Plug in connectors for...

Page 6: ...rs are blocked when closed 1 When equippedwith electrical accessories such as LED CELS or heating wire Lead wires through cable duct and out the cornerpiece 2 Place external trafobox Recommended order...

Page 7: ...Place cable duct covers horizontaly according to illustration above 4 Connect line cord in socket tie up cord to prevent loss during placement 5 Slide bar in place 6 Adjust feet to level out bar and...

Page 8: ...TBMU 1 X TBMU 2 X TBMU 3 X TBMU 4 X TBMU 5 X 1HB 1 X TB1 1 X TB1 2 X TB1 3 X TB1 4 X TB1 5 X VS20 1 X TBVS 1 X TBVS 2 X TBVS 3 X TBVS 4 X TBVS 5 X VS00 X TBEX 1 X TBEX 2 X TBEX 3 X TBEX 4 X TBEX 5 48...

Page 9: ...1 DMX address 0 0 1 Controller Gamko example Driver Bar 2 slave 0 example Driver Bar 3 slave 1 External DMX device master DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out DMX in DMX out RJ...

Page 10: ...ports cablecut when all of the above hasn t solved the problem replace part of cable harness Colour within one segment differs one or more colour within the LED is broken but still closes the power ci...

Page 11: ...screws from evaporator cover 6 Place unit bracket to remove unit 7 Disconnect main powersupply connector and pull out unit 8 Drill a hole 85mm in center of X 1HB at 355mm from front 9 Break out knock...

Page 12: ...n met scharniergat zie illustratie zorg ervoor dat de magneet uitlijnt met de 1 Connect reed switches in series 2 Make sure the gap between the reed switches and the magnet is not too big if necessary...

Page 13: ...LS 55 Keyswitch 013050129 Cuff round 013050129 Retaining nut 013050129 Relais block 013050130 2x improved assembly order keyswitch lock relais blocks wiring diagram relais blocks CELS keyswitch ATTENT...

Reviews: