©2017 CoolSystems, Inc. All Rights Reserved
Game Ready Dual Action Wrap Use Guide
Hand/Wrist Wrap PN 704581 Rev A
COOLSYSTEMS
®
, INC.
1800 Sutter Street, Suite 500
Concord, CA 94520 USA
1.888.GAM1.510.868.2100
www.gameready.com
GENERAL
IMPORTANT
DO NOT SET THE GAME READY SYSTEM OR MED4 ELITE SYSTEM TO HIGH
PRESSURE WHEN USING THE HAND/WRIST WRAP.
READ THIS COMPLETE USE GUIDE AND GAME READY GRPRO 2.1 SYSTEM USER
MANUAL AND/OR MED4 ELITE SYSTEM USER MANUAL INCLUDING INDICATIONS,
CONTRAINDICATIONS, CAUTIONS AND WARNINGS BEFORE USING THIS
PRODUCT!
WARNINGS
• THIS WRAP PROVIDES AN OPTIONAL INSULATING LAYER. IF
EXPERIENCING EXCESSIVE HEATING OR COOLING IN THE DIGITS,
ENGAGE THE ADDITIONAL INSULATION AS NEEDED OR ADJUST THE
CONTROL UNIT TEMPERATURE.
• FOLLOW RECOMMENDATION OF PHYSICIAN FOR APPROPRIATE USE OF
INSULATING LAYER.
• NOT TO BE USED CONTINUOUSLY FOR GREATER THAN 15 MINUTES PER
TREATMENT SESSION.
• Follow the recommendations of your health care practitioner regarding the
frequency and duration of use.
• Improper placement or prolonged use of the Game Ready System or Med4 Elite
System could result in tissue damage. During the course of therapy, patients
should monitor the skin surrounding the treated region or the digits of the
extremities of the treated limb for any burning, itching, increased swelling, or
pain. If any of these signs present, or any changes in skin appearance occur (such
as blisters, increased redness, discoloration, or other noticeable skin changes),
patients are advised to discontinue use and consult a physician.
• Game Ready Wraps are not sterile; do not place directly against open wounds,
sores, rashes, infections, or stitches. The Wrap may be applied over clothing
or dressing. A layer of clothing between Wrap and skin is recommended for all
patients.
• Game Ready Wraps are available in multiple configurations but are not intended for
all possible physiologic uses. For example, the Ankle Wrap is not designed for use
on the toes and the Back Wrap is not designed for use in the abdominal region.
• To avoid potential damage to the Control Unit, do not use other manufacturers’
Wraps with the Control Unit.
• Use extra caution during the immediate postoperative period, especially when
sedated or on any medication that could alter normal pain sensation. Check the
skin of the treated region frequently and use mid-to-higher (warmer) temperature
range settings or leave more time between treatments, if necessary.
• Monitor the level of heat throughout treatment session. Caution should be
used with the Med4 Elite System or any thermotherapy (Heat Therapy) device
generating high intensity heat at 113°F or above. Check the skin of the treated
region frequently and use mid-to-lower (cooler) temperature range settings or
leave more time between treatments, if necessary.
• The Med4 Elite System is not intended for use with numbing agents.
• When using heat and rapid contrast therapy, skin should be protected in heat-
sensitive or high-risk patients, especially over regions with sensory deficits.
• Heating of the gonads should be avoided.
NOTES
Apply Wrap with a uniformly close fit, ensuring there are no kinks which may impede
water flow. Ensure connector hose is placed to prevent the Wrap from folding or
kinking at the hose inlet location of the Wrap.
CARE AND CLEANING
For daily care and to minimize formation of mildew, remove Heat Exchanger from
Sleeve and wipe with dry towel to remove any condensation that may form. Turn
Sleeve inside out and hang both the Sleeve and Heat Exchanger to release excess
moisture. For multi-patient use, if needed, use Sterifab® according to manufacturer’s
instructions to minimize microbe transfer.
For extended care, carefully remove the Heat Exchanger from the Sleeve and turn the
Sleeve inside out. Hand or machine wash the Sleeve in cold water and mild detergent,
or antibacterial soap. Hang to dry. Hand wash the Heat Exchanger with warm water
and mild detergent, do not machine wash or place in a dryer. Hang to dry.
AVERAGE LIFE EXPECTANCY
The life expectancy of Sleeves and Heat Exchangers will vary widely depending on
frequency of use. Please reference chart below to determine when to replace product.
Sleeve
Light Use (Personal) ............................................................ 12 months
Medium Use ....................................................................... 6 months
Heavy Use (Clinic or training facility) .................................. 3 months
Heat Exchanger
Light Use (Personal) ............................................................ 24 months
Medium Use ....................................................................... 18 months
Heavy Use (Clinic or training facility) .................................. 12 months
WARRANTY INFORMATION
Sleeve:
In case of manufacturer defect, Sleeve may be returned within 7 days of
purchase.
Heat Exchanger:
1 year from date of purchase. See warranty card included with
Heat Exchanger.
CONTACT US
In the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100).
From outside of the U.S. please refer to www.gameready.com to find your local
distributor’s contact information.
A list of current patent(s) covering Game Ready technology can be found at:
www.gameready.com/patents.
Symbol for “assembled in” a specific country (XXXX).
Symbol for “made in” a specific country (XXXX).
Warning:
To comply with California Proposition 65, the following warning has been
included:
This product contains chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
Wrap
(PN 590811-03)
includes Sleeve
(PN 510811)
& Heat Exchanger
(PN 520811-03)
REMOVAL OF HEAT EXCHANGER
1. Disconnect the Connector Hose from the Wrap
2. Unzip the zipper
3. Gently pull out the Heat Exchanger
STORAGE OF YOUR WRAP
Hang your Wrap on a wide hanger or lay flat.
Do not fold or stack it, as this could kink the
fluid chamber and the Wrap will not work
properly.
EMERGO EUROPE
Prinsessegracht 20
2514 AP The Hague
The Netherlands
EMERGO AUSTRALIA
201 Sussex Street
Darling Park, Tower II, Level 20
Sydney NSW 2000
Australia
SUPERSEDED
Summary of Contents for ATX HAND
Page 5: ...PN 510811 PN 520811 03 PN 590811 03 1 3 5 6 4 2 2 GAME READY GRPRO 2 1 MED4 ELITE SUPERSEDED...
Page 33: ...520811 03 510811 590811 03 1 3 5 6 4 3 GAME READY GRPRO 2 1 MED4 ELITE 2 2 SUPERSEDED...
Page 37: ...PN 510811 PN 520811 03 PN 590811 03 1 3 5 6 4 3 2 2 GAME READY GRPRO 2 1 MED4 ELITE SUPERSEDED...
Page 61: ...PN 520811 03 PN 510811 PN 590811 03 1 3 5 6 4 GAME READY GRPRO 2 1 MED4 ELITE 2 2 SUPERSEDED...