PRECAUTIONS

    

Caution: This product is for veterinary use only and is not indicated for human use. 

    

Caution: Always attend the animal while the Game Ready Veterinary System is being  

 

   used, in the case that the animal needs to be quickly disconnected from the Control Unit.

  

Do not operate the System without any water in the ice box.

  

Never operate the System with damaged power cords or Connector Hoses, or other 

    mechanical damage, or if the unit is otherwise not fully operational.

  

Do not pour hot water into the ice box. The System was not designed to operate, and 

    has not been tested, with hot water.

  

Do not pick up the Control Unit by the lid. Carry using the handle only.

  

Do not use other manufacturers’ wraps with the Game Ready System.

  

Do not operate the Control Unit without a Connector Hose attached.

  

Be careful not to trip over the System’s power cords and Connector Hose, or use the    

  product where these are likely to trip an animal.

  

The Game Ready Control Unit is a veterinary medical device. 

Handle it with the same    

  care as you would a laptop computer. 

Do not drop it, kick it or otherwise abuse  

 

  it unnecessarily. Such abuse will void all Game Ready warranties. Do not place the AC    

  Adapter or battery pack inside the ice box for storage or transport.

 

  In addition to the precautions listed above, additional warnings and safety precautions    

  are posted throughout this manual. Read and carefully follow these instructions prior to    

  operating the System.

Summary of Contents for 550450

Page 1: ...VETERINARY CONTROL UNIT User s Manual MODEL 550450 User s Manual also available online at www gamereadyveterinary com...

Page 2: ..._____________________ 8 Using Your Game Ready System ______________________________ 11 Cleaning ___________________________________________________ 16 Maintenance _____________________________________...

Page 3: ...and veterinarians to expand breakthrough discoveries into the realm of sports medicine for both people and animals R E G I S T E R Y O U R P R O D U C T Please complete your Warranty Registration for...

Page 4: ...4...

Page 5: ...loration or other noticeable skin changes you are advised to discontinue use and consult a veterinarian The Game Ready Wrap is not sterile do not place directly against open wounds sores rashes infect...

Page 6: ...Unit by the lid Carry using the handle only Do not use other manufacturers wraps with the Game Ready System Do not operate the Control Unit without a Connector Hose attached Be careful not to trip ove...

Page 7: ...in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Page 8: ...Pressure Indicator Coldest Wrap Temperature Average Wrap Temperature MODES OF OPERATION Manual Mode The System defaults to this mode and allows the user to adjust time and pressure settings Program Mo...

Page 9: ...emperature The Control Unit cools the Wrap by pumping water from the ice box into the Wrap therefore the temperature of the Wrap will never be colder than the water in the ice box If the knob is turne...

Page 10: ...he average temperature of the Wrap averages the temperature of the water going into and out of the Wrap Coldest Wrap Temperature Indicates an estimate of the temperature of the water going into the Wr...

Page 11: ...referred to throughout this manual as a Wrap The Game Ready Control Unit should be placed on a stable surface such as the floor or a table during use Please note that using the System in an environme...

Page 12: ...result in inadequate therapy Unplug the Control Unit from the electrical outlet prior to filling the Control Unit with ice and water STEP 1 Push the door release button to open the ice box door STEP...

Page 13: ...the outlet is receiving power If necessary try an alternate outlet or power supply If the light is still not illuminated and the Control Unit will not turn on please contact Game Ready Customer Servic...

Page 14: ...ame Ready Customer Service from the U S call Toll free at 1 888 426 3732 from outside of the U S call 001 510 868 2100 Warnings Follow the recommendations of your veterinarian Improper placement or pr...

Page 15: ...et the time by pushing the buttons Set the pressure by pushing the pressure button You can select from 4 pressure settings No pressure Low Pressure 5 15 mmHg Medium Pressure 5 50 mmHg High Pressure 5...

Page 16: ...ing Mild detergent 70 Isopropyl alcohol We do not recommend the use of Quaternary Ammonium such as Virex DO NOT USE Phenolic based disinfectants such as Amphyl Any solvent based cleaners on the Connec...

Page 17: ...ocation Store the Control Unit with the lid fully open to allow the interior to dry and preserve the ice box seal Remember that your Game Ready Control Unit is a valuable piece of equipment and should...

Page 18: ...not clogged Make sure there are no kinks in the Wrap or Connector Hose Turn the Control Unit off and on again Disconnect and reconnect the hose from the Control Unit and the Wrap Prime the Wrap using...

Page 19: ...t off and back on again Check to see if the filter is clogged If that does not solve the problem turn the Control Unit off for 20 minutes to let the pump cool down before turning it on again to try ag...

Page 20: ...MA number on the outside of the package CoolSystems will not accept returned Game Ready Control Units without an RMA number on the package If you return the Game Ready Control Unit to CoolSystems you...

Page 21: ...OM JURISDICTION TO JURISDICTION W A R R A N T Y R E G I S T R A T I O N Please complete the Warranty Registration for both the Game Ready Control Unit and the Wraps online at www gamereadyveterinary c...

Reviews: