1. Disconnect the power source.
2. Using Table 2 to determine the recommended mounting height, select a mounting location for the hand dryer where no reflective
surfaces or objects (such as a hand basin) are directly under the infra-red sensor eye. The infra-red sensor eye is visible from the
bottom of the dryer. The minimum mounting distance from bottom of the dryer to a reflective surface is 18" (46 cm). When two or
more dryers are installed, they should be spaced apart 24" (61 cm)
3. Use the security hex key supplied to turn the cover mounting screws
clockwise to remove the cover from the dryer.
4. Using the mounting template provided, mark locations for the 4 mounting bolt holes on the wall.
5. Fasten the base to the wall, using the type of bolts recommended in Table 3
6. Each dryer must have its own dedicated circuit.
7. Connect the dryer to the nearest suitable distribution panel.
8. Replace cover, turn screws
counter-clockwise making certain not to over-tighten.
IMPORTANT:
Consult local and general regulations before performing dryer installation. Ensure the electrical network is
not overloaded. Always connect to a dedicated branch circuit with circuit breaker or fuse protection and an electrical rating
greater than the model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications in accordance with the
NEC (National Electrical Code) and/or CEC (Canadian Electrical Code).
The dryer can be operated with the heating element "ON" or "OFF".
Note: The factory setting for the heating element is "ON".
Installation
Adjusting Heating Element Controls
Recommended Mounting Heights from Floor to Dryer Bottom Edge
in. (cm.)
Men’s washrooms
46" (117)
Women’s washrooms
44" (112)
Children’s washrooms, ages 4-7
32" (81)
Children’s washrooms, ages 7-10
36" (91)
Children’s washrooms, ages 10-13
40" (102)
Children’s washrooms, ages 13-17
44" (112)
Handicap Mounting Height
37" (94)
Type of Wall
Type of Bolt
Minimum Bolt Length
Hollow Tile, Lath, Wall Board or Metal
1/4" (M6) screw Type or Wing Type toggle
Bolts
Dependent on wall thickness
Cement, Brick, or Tile Covered Cement or Brick
1/4" (M6) Stud Type Expansion Bolts
3" (76mm)
Stud Wall with wood Backing
No 16 (M8) Wood Screws
2-3/4" (70mm)