background image

 

Version 1, 18 December 2020, Page 

1

 of 

12

 

 

Safe-Cell

® 

Ducted Dual Flush Pan Assembly  

 for Mains with Controller 

 

PRODUCT CODE: 

 

 

TZ-FLOWTPANMDT

 

 

SPECIFICATIONS

 

Safe-Cell

®

 Electronic dual flush pan assembly provides the complete anti-vandal, anti-ligature 

solution. The unique electronic valve assembly provides a precise delivery of water, and is 
specifically designed for prisons, mental health facilities and other custodial establishments. 

4mm thick, exposed stainless steel faceplate to suit back mounted applications and steel face plate 
features push activation buttons. Plates have no front penetrations and are fixed from the duct. 

Solenoid is a Watermarked high flow, low-pressure loss control valve. The body and outer casing are 
made from Nylon and features a stainless steel plunger and nitrile diaphragm.

 

Safe-Cell

® 

Electronic controller is a 24V AC electronic control system allowing connection of up to 2 

button inputs and up to 2 solenoids (single solenoid only for flushing units). Controller is pre-
programmed and ready to use. The solenoids will open for a specific time once the appropriate 
button is pressed. The standard program can be modified to suits individual needs. To modify the 
operation settings a compatible Android device with Bluetooth is required.

 

 

TECHNICAL DATA

 

Power Supply 

Type 

Transformer 

Input 

230-240V 

– 50Hz 

Output 

24V AC 0.9AMPS 22VA 

Cable length 

3m 

Solenoid 

Input Voltage 

24V AC 

– 50Hz 

Power Consumption 

4.5VA 

Cable length 

5m 

Connection 

Inlet 

1” BSP - Female 

Outlet 

2” BSP - Male 

Pressure Range 
(kPa) 

Min 

70 

Max 

500 

Temperature (°C) 

Min 

Max 

40 

Sensor 

Type 

IP68 24V 

Activation 

Push Button 

Connections 

2 pin connector 

Cable length 

5m 

Controller 

Input Voltage 

24V AC 

Program type 

Flowmatic 

Connections 

2 pin connectors 

Finish (user) 

Stainless Steel 

Minimum Delivering Flow Rate (Litres per second) 

1.5 @ 350kPa dynamic pressure (flow) 

    * - The minimum pipe size serving the flush valve shall be DN 25. 

NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. 

 

Summary of Contents for Safe-Cell TZ-FLOWTPANMDT

Page 1: ...utton inputs and up to 2 solenoids single solenoid only for flushing units Controller is pre programmed and ready to use The solenoids will open for a specific time once the appropriate button is pres...

Page 2: ...quired to minimise ligature points and areas for concealment of contraband In addition to ensuring the products are fitted securely and in accordance with the following instructions consideration shal...

Page 3: ...mend 300mm from the centre of the outlet and at a suitable height or to project specification Cut out details for face plate Faceplate to suit wall thickness between 30mm to 240mm Ensure the cut out d...

Page 4: ...nyloc nuts and apply a thin bead of silicon on the edge of the wall cut out If extension leads are required please contact Galvin Engineering Do not force the faceplate to fit onto wall or attempt to...

Page 5: ...ic nylon or electrical parts and seals and will void the warranty Note Controller must be mounted away from any moisture or potential water splashing 4 Mount control module Attach the control module t...

Page 6: ...red please contact Galvin Specialised Do not cut the leads If the leads are too long it is recommended that any excess is coiled up and clipped to the wall 6 Connect power supply and check for correct...

Page 7: ...scanning the first thing to come up in available devices will be a Mac address that looks like this example AB EC 69 57 34 02 This will eventually change to the name of the device which is from factor...

Page 8: ...ory parameters will be downloaded to the app The Get log button will pop up the log data screen The Presets button will list all saved presets Drop Down menus First menu from left is to select the typ...

Page 9: ...p down menu The PB2 controller can be used for showers basins and pans Depend of the feature selection setting slides will appear e g there is only Run time to be set for basin Run and Lockout times f...

Page 10: ...nd Hygiene flush for full flush channel 2 and press Upload 10 Settings for shower PB2 controller is capable of controlling two buttons and two showers solenoids Select channel to be changed Select des...

Page 11: ...ck electrical connections Replace solenoid valve Water or structural damage to electrical components Replace damaged electrical components Incorrect connections Check all connections Damage to sensor...

Page 12: ...the only warranty given by the Galvin Engineering Pty Ltd With respect to the product Galvin Engineering Pty Ltd makes no other warranties express or implied Galvin Engineering Pty Ltd hereby specific...

Reviews: