PRE-INSTALLATION

 

MOUNTING DETAILS 

– HOLE CENTRES

 

 

If the mounting holes do not already exist, mark out and drill the holes in the wall/sheet, as shown in rough-in dimensions. 

Note:  Before installation, all lines must be flushed.  We recommend that a line strainer be installed prior to drinking taps to  
eliminate any foreign material.

 

 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

INSTALLATION

 

IMPORTANT: Galvin Engineering products must be installed in accordance with these installation instructions and in 
accordance  with  AS/NZS  3500,  the  PCA  and  your  local  regulatory  requirements.  Water  and/or  electrical  supply 
conditions must also comply to the applicable national and/or state standards. Failing to comply with these provisions 
shall void the product warranty and may affect the performance of the product. 
 

     

When applying thread tape or sealant to the inlet, ensure the opening is not blocked. Failure to do so may cause the 

regulating screw to be blocked, which will affect the flow of water. 

 

 

1. Fit tap assembly 

  Follow the rough in dimensions above and 

ensure the orientation of the mounting holes is 
as shown. 

  Fit supplied wall plugs. 

  Screw bottle filler assembly clockwise on wall 

spud until it is in the correct position. Ensure 
thread tape is used. 

2. Secure the body 

  Secure the body with supplied screws. 

 

Rough-in Dimensions 

Summary of Contents for Ezy-Drink SS

Page 1: ...nk lever bottle filler taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECHNICAL DATA Inlet BSP Female Outlet Water diffuser Headwork Lever action Working Pressure Range kPa Min 50 Max 500 Working Temperature Range C Min 5 Max 60 Nominal Flow Rate LPM 1 7 Finish Stainless Steel NOTE Galvin Engineering continually strive to improve their products Specific...

Page 2: ... requirements Water and or electrical supply conditions must also comply to the applicable national and or state standards Failing to comply with these provisions shall void the product warranty and may affect the performance of the product When applying thread tape or sealant to the inlet ensure the opening is not blocked Failure to do so may cause the regulating screw to be blocked which will af...

Page 3: ...NG PROBLEM CAUSE RECTIFICATION Inconsistent flow Blocked top assembly or regulating screw Remove top assembly and or regulating screw and clean Water is not flowing from tap Water is turned off Turn on water Blocked regulating screw Remove regulating screw and clean Continuous flow Top assembly loose or internally obstructed or damaged Remove top assembly clean with water and re grease spindle if ...

Page 4: ...manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s warranty are complied with The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and Galvin Engineering Pty Ltd sh...